AQUATECH DBX2 Manuale utente

AQUATECH SCIENTIFIC INSTRUMENTS LLC
MBAR
ASI
DBX2

No part of this manual may be reproduced in any form, or by any
means, without permission in writing from (ASI), except for your
personal use with this product.
Copyright 2021 by AQUATECH SCIENTIFIC INSTRUMENTS LLC
independent laboratory test a sample set of our units for accuracy. (ASI) in
no event will be liable for direct, indirect, special, incidental or consequential
damages resulting from a defect in the unit.
See warranty information on page 18 of this manual.
Please read through this entire manual to become familiar with this unit's
functions. If you have any questions, please contact us. *See page 18
for contact information.
Table of contents
Introduction............................................................................................. 1
Unit overview.......................................................................................... 2
Control overview..................................................................................... 3
Setup your unit for Sea level Pressure...................................................
4
System Setup 1...................................................................................... 6
7
Interpreting the pressure graphs............................................................ 8
10
11
Forecasing screen.................................................................................
12Wiring harness information.................................................................... 13
Accessories........................................................................................... 14
Display overview.....................................................................................
The DBX2 is a precision digital barometer. The DBX2's intended use is to
detect changes in atmospheric pressure. No other use is described.
All rights reserved.
AQUATECH SCIENTIFIC INSTRUMENTS LLC (ASI) has had an outside
Unit setup overview................................................................................ 5
9
Unit specifications................................................................................. 15
16
17
18
Trouble shooting and FAQ....................................................................
Warranty and contact information..........................................................
System Setup 2......................................................................................
Desktop unit specs................................................................................
Flush mount unit specs.........................................................................
Terms and Definitions............................................................................

2. Plug the DBX2 in with the provided AC/DC wall adapter.
1. Unpack the DBX2 Digital Barograph and accessories.
POWER CONSUMPTION:
20.0 mA @ 5.0 volts in standard operation mode.
80.0 mA @ 5.0 volts in standard operation mode with LED backlight on.
3. Read through instructions and set your elevation.
MBAR
ASI
DBX2
1
2
3
4 5 6 7 8
IMPORTANT: FORECASTS AND WARNINGS ARE BASED ON
YOUR SEA LEVEL PRESSURE AND CORRECT ELEVATION.
6
54
32
9
10
9
10

29.802
MBAR
1013.70
** ALL FORMATS **
*** USER SETTINGS ***
0612182430
01234567
HI 30.025 LO 29.805
HI 1030.4 LO 983.7
ELEV +167' +50M
** UNIT INFORMATION **
29.802
1 HR
4 HR
-0.040
+0.080

MBAR
ASI
DBX2

Barometers are usually setup for SEA level pressure. SEA level
pressure is the actual LOCAL air pressure at your elevation,
plus the additional air pressure below your elevation down to sea
level. All world pressure maps use this format. By adjusting your
pressure to SEA level, you can easily compare your pressure
reading with other locations around the world. The DBX2 uses
The LOCAL pressure is the actual air pressure at your elevation.
Local pressure is generally used in the research, automotive,
medical fields, testing laboratories, manufacturing, etc.
The Threshold alert allows the user to set a pre-determined
pressure that when reached will signal an audible and visual
alarm.
When first setup the 1-Day and 1-Week graph will show only one
bar on the right side of the screen. The 1 day graph will add
a bar every hour and the 1-Week graph will add a bar every 4 hours.
an ELEVATION value to adjust the SEA level pressure.
The DBX2 is calibrated to read the actual LOCAL pressure.
when MODE is set to USER.
IMPORTANT: FORECASTS AND WARNINGS ARE BASED ON
YOUR SEA LEVEL PRESSURE AND CORRECT ELEVATION.
The DBX2 makes it easy to offset the local pressure to
a user determined value. Once set the user pressure will be
the local pressure plus the user offset and will be displayed

To set your SEA LEVEL PRESSURE you only need to know your
elevation above sea level. You can determine your elevation through
a mobile phone with GPS capabilities or you can use a program such
as google earth to pin down your elevation. Then simply enter this
elevation as FEET in the DBX2 setup.
Your unit can display 21 different pressure formats by pressing:
IMPORTANT: FORECASTS AND WARNINGS ARE BASED ON
YOUR SEA LEVEL PRESSURE AND CORRECT ELEVATION.

= AUDIBLE ALERT IS ON
= AUDIBLE ALERT IS OFF
= FALLING PRESSURE
= RISING PRESSURE
= FIELD SECTION ARROW
** PREFERENCES **
= STEADY PRESSURE = THRESHOLD ALERT
(PREFERENCES)
= SEQUENCE MODE IS SET
= FIELD SECTION ARROW

SET ELEVATION
SET THRESHOLD
SET CALIBR OFFSET (UNIT CALIBRATION)
SET USER OFFSET (USER)
(THRESHOLD)
(ELEVATION)

29.891
30.410
29.753
30.085
30.208 6
30
0
0121830 24
12 0624 18
6 01230 1824
6
12 630 1824
30 12 01824
HI 30.24 LO 29.89
HI 30.20 LO 29.60
HI 30.41 LO 29.45
HI 30.20 LO 29.75
HI 30.12 LO 30.06