artisan GSP-810 Manuale utente

Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra

GSP-810 Spectrum Analyzer
0
Spectrum Analyzer
GSP-810
Operation Manual
© 1999 GOODWILL Instrument Co., LTD. All rights reserved
GW Part No: 82SP-81000MB
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

GSP-810 Spectrum Analyzer
1
Table of Contents
1.0 GENERAL DESCRIPTION AND FEATURES........................................................................................ 3
2.0 USAGE PRECAUTIONS AND RECOMMENDATIONS ........................................................................ 3
3.0 PANEL DESCRIPTIONS ........................................................................................................................ 7
4.0 SETUP AND USE ................................................................................................................................. 11
5.0 QUICK USE INDEX .............................................................................................................................. 27
6.0 SPECIFICATIONS ................................................................................................................................ 28
APPENDIX 1 - REMOTE OPERATION...................................................................................................... 31
Due to continuous improvements in the GSP-810 Spectrum Analyzer, information
contained in this Manual is subject to change without notice.
Contact GW, for revisions and corrections.
Goodwill Instrument Co., LTD.
NO. 95-11, PAO-CHUNG ROAD, HSIN-HIEN CITY,
TAIPEI HSIEN, TAIWAN
Telephone – 886-2-29179188
Fax – 886-2-2918-3190
URL -http://www.goodwill.com.tw
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

GSP-810 Spectrum Analyzer
2
EC Declaration of Conformity
We
GOOD WILLINSTRUMENT CO., LTD.
(1) No. 95-11, Pao-Chung Rd., Hsin-Tien City, Taipei Hsien, Taiwan
(2) Plot 522, Lorong Perusahaan Baru 3, Prai Industrial Estate, 13600
Prai, Penang, Malaysia
declare, that the below mentioned product
GSP-810
are herewith confirmed to comply with the requirements set out in the
Council Directive on the Approximation of the Law of Member States
relating to Electromagnetic Compatibility (89/366/EEC, 92/31/EEC,
93/68/EEC) and Low Voltage Equipment Directive (73/23/EEC).
For the evaluation regarding the Electromagnetic Compatibility and Low
Voltage Equipment Directive, the following standards were applied:
EN 61326-1: Electrical equipment for measurement, control and laboratory use ––
EMC requirements (1997+A1: 1998)
Conducted and Radiated Emissions
EN 55011 class A: 1991 Electrostatic Discharge
EN 61000-4-2: 1995
Current Harmonic
EN 61000-3-2: 1995 Radiated Immunity
EN 61000-4-3: 1996
Voltage Fluctuation
EN 61000-3-3: 1995 Electrical Fast Transients
EN 61000-4-4: 1995
Surge Immunity
EN 61000-4-5: 1995
Conducted Susceptibility
EN 61000-4-6: 1996
Power Frequency Magnetic field
EN 61000-4-8: 1993
Voltage Dips/ Interrupts
EN 61000-4-11: 1994
Low Voltage Equipment Directive 73/23/EEC & amended by 93/68/EEC
Safety Requirements
IEC 61010-1: 1990+A1: 1992+A2: 1995
EN 61010: 1990+A1: 1992+A2: 1995
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

GSP-810 Spectrum Analyzer
3
1.0 General Description and Features
The GSP-810 is designed for minimal set-up and adjustment. The user interface
allows fast and accurate measurements. The fully synthesized design of the GSP-
810 permits stable operation down to 2 kHz / division.
2.0 Usage Precautions and Recommendations
The following precautions are recommended to insure your safety and to provide the
best condition of the GSP-810.
Safety Terms and Symbols
These terms may appear in this manual or on the product:
WARNING: Warning statements identify condition or practices that could
result in injury or loss of life.
CAUTION: Caution statements identify conditions or practices that could result
in damage to this product or other property.
The following symbols may appear in this manual or on the product:
DANGER ATTENTION Protective Earth (ground)
High Voltage refer to Manual Conductor Terminal
Terminal
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

GSP-810 Spectrum Analyzer
4
FOR UNITED KINGDOM ONLY
NOTE: This lead / appliance must only be wired by competent persons
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in this lead are coloured in accordance with the following code:
Green/ Yellow: Earth
Blue: Neutral
Brown: Live (Phase)
As the colours of the wires in main leads may not correspond with the colours
marking identified in your plug/appliance, proceed as follows:
The wire which is coloured Green & Yellow must be connected to the Earth
terminal marked with the letter E or by the earth symbol or coloured Green or
Green & Yellow.
The wire which is coloured Blue must be connected to the terminal which is
marked with the letter N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the terminal marked with
the letter L or P or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment or contact the
supplier.
This cable/appliance should be protected by a suitably rated and approved HBC
mains fuse: refer to the rating information on the equipment and/or user
instructions for details. As a guide, cable of 0.75mm2should be protected by a 3A
or 5A fuse. Larger conductors would normally require 13A types, depending on the
connection method used.
Any moulded mains connector that requires removal /replacement must be
destroyed by removal of any fuse & fuse carrier and disposed of immediately, as a
plug with bared wires is hazardous if a engaged in live socket. Any re-wiring must
be carried out in accordance with the information detailed on this lable.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

GSP-810 Spectrum Analyzer
5
Use and Wear
CAUTION
•Do not exceed +30 dBm into the RF INPUT or +30 dBm reverse power into the
TG OUTPUT.
•Do not place any heavy object on the instrument.
•Avoid severe impacts or rough handling that could damage the GSP-810.
•Use electrostatic discharge precautions while handling and making
connections to the GSP-810.
•Do not place wires into the connectors of the GSP-810, only mating connectors
and adapters.
•Do not block or obstruct cooling fan vent opening on side panels or on the rear
panel of unit.
1) Disassembly of the Instrument
•Do not disassemble the instrument; refer the instrument to a factory approved
service facility only.
2) AC Power Input
CAUTION
•AC input should be within the range of selected line voltage +/- 10%.
•Insure the correct fuse is installed prior to applying voltage for the first time -
90 V ~ 132 VAC input : T 1A / 250V
198 ~ 250 VAC input : T0.5A / 250V
•Check the line voltage setting on the rear panel. If the line voltage does not
match input voltage, change as follows:
a) Remove AC Power Cord;
b) Open cover of AC socket with flat blade screwdriver;
c) Remove selector Cam Drum and rotate to the correct voltage selection
d) Replace Cam Drum.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

GSP-810 Spectrum Analyzer
6
3) Grounding
WARNING
•To avoid electrical shock, the power cord protective grounding conductor must
be connected to earth ground.
4) Fuse Replacement
WARNING
•For continued fire protection, replace the fuse with the specified type and rating
only.
•Disconnect power cord before replacing fuse.
•If the fuse is blown, there is something wrong with the instrument. Repair the
cause of fault before replacing fuse.
5) Cleaning
•Disconnect AC Power Cord from the instrument before cleaning.
•Use a soft cloth dampened in a solution of mild detergent and water. Do not
spray any liquid into the unit.
•Do not use chemicals or cleaners containing benzene, toluene, xylene,
acetone or other harsh chemicals.
6) Operating Environment
•The following conditions are recommended for optimum use of the instrument -
Indoor Use Altitude < 2000 m Temperature 18° to 28° C Relative Humidity < 90%
Dust Free No direct sunlight No strong magnetic fields
•Installation Category: II
•Pollution degree: 2
7) Storage Environment
•The following conditions are recommended for optimum storage of the
instrument -
Indoor Temperature 0° to 40° C Relative Humidity < 85%
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

GSP-810 Spectrum Analyzer
7
3.0 Panel Descriptions
Front Panel
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

GSP-810 Spectrum Analyzer
8
Item Description
1 Cathode Ray Tube (CRT) Display, 8 x 10 graticule, 5 inch
2 Liquid Crystal Display (LCD), 4 line x 20 character
3 Keypad, field selection and data entry
4 Spinner, field selection and data change
5 RF Input, Coaxial, Type N Female
6 Tracking Generator Output, Coaxial, Type N Female (optional)
7 Switch, Power ON / OFF
8 Adjustment, CRT Trace Rotation, potentiometer
9 Control Knob, Volume (optional demod receiver)
10 Phone Jack, head set output, (optional demod receiver)
11 Control Knob, CRT Focus
12 Adjustment, CRT Y-axis position, potentiometer
13 Control Knob, CRT Intensity
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Indice
Altri manuali artisan Strumento di misura





















