ATEQ F6Class Manuale utente

ATEQ F6Class
Quick Start Guide

QSG_F6CLASS.376.00_EN_01 / 2019-03-25
2/02
Table of contents
Safety advisory / Warranty
Good practices and safety instructions 4
Air quality requirements 5
Preamble
ATEQ F6Class, a universal leak tester 6
Leak test 6
Principle of a cycle 7
Your ATEQ F6Class
Front panel 8
Connectors on the back panel (with all options) 9
Power supply connectors 11
Digital links 12
Digital inputs/outputs 12
Pneumatic connectors 15
Pneumatics configuration 17
User interface
Overview 19
Keys 19
Display 20
Starting up
Power up 22
Preparing a program 22
Modifying a parameter 23
Selecting a program 24
Starting and stopping current cycle 24
User adjustments
Options of the menus 25
Specifications
Characteristics 31

QSG_F6CLASS.376.00_EN_01 / 2019-03-25
3/32
ATEQ Manufacturer Plants - Measurement Solution, Global Leader.
ATEQ
15, rue des Dames, Z.I.
78340 LES CLAYES-SOUS-BOIS
FRANCE
ateq.com
T.: +33 1 30 80 1020
F.: +33 1 30 54 1100
ATEQ K.K.
3 – 41 ATEQ Building, Ikehata
Chiryu-city, Aichi-pref
JAPAN
ateq.co.jp
T.: +81 566-84-4670
F.: +81 566-84-4680
ATEQ China
98 Jian Peng Lu
Shanghai
CHINA
ateq.com.cn
T.: +86 21 6763 9508
F.: +86 21 6763 9528
ATEQ SYSTEMS ANALYSIS
TAIWAN CO., LTD.
NO. 3, LAN 223, San Jia Dong
Street
40642, TAICHUNG
TAIWAN
ateq.com.tw
T.: +886 4 2437 5278
F.: +886 4 2437 3675
ATEQ CORP.
35980 Industrial Road Suite L
Livonia MI 48150
UNITED STATES
atequsa.com
T.: +1 734-838-3100
F.: +1 734-838-0644
We continuously work on improving our products. This is why information contained in this
manual, the device and the technical specifications may be modified without prior notification.
Pictures and figures in this manual are non-contractual.

QSG_F6CLASS.376.00_EN_01 / 2019-03-25
4/32
Safety advisory / Warranty
GOOD PRACTICES AND SAFETY INSTRUCTIONS
Safety recommendations
If the device is supplied with 100/240VAC, it is mandatory to connect it to the ground with
a good link to the ground, to protect against electric hazard or electrocution.
It is dangerous to change the status of the outputs.
They can control power actuators or other equipment (mechanical, pneumatic, hydraulic,
electrical or other) which can cause serious personal injury and damage to surrounding material.
For safety and quality measurement reasons, it is important, before powering on the device,
to ensure that it is air supplied with a minimum operating pressure (0.6MPa (87PSI) ± 15%).
Recommendations for the test environment
Keep the test area as clean as possible.
Recommendations for operators
ATEQ recommends that the operators who use the devices have training and a level of
qualification that correspond to the job to perform.
General recommendations
— Read the user manual before using the device.
— All electrical connections to the device must be equipped with safety systems (fuses,
circuit breakers, etc.) adapted to the needs and in accordance with the applicable
standards and rules.
— To avoid electromagnetic interference, electrical connections to the device must be
shorter than 2 meters.
— Power supply plug must be grounded.
— Disconnect the device from the mains before performing any maintenance work.
— Shut off the compressed air supply when working on the pneumatic assembly.
— Do not open a connected device.
— Avoid splashing water on the device.
ATEQ is at your disposal for any information concerning the use of the device under
maximum safety conditions.
We draw your attention to the fact that ATEQ cannot be held responsible for any
accident related to a misuse of the measuring instrument, the workstation or non-
compliance of the installation with safety rules.
In addition, ATEQ declines any responsibility for the calibration or the fitting of their
instruments that is not done by ATEQ.
ATEQ also declines any responsibility for any modification (program, mechanical or
electrical) of the device done without their written consent.

QSG_F6CLASS.376.00_EN_01 / 2019-03-25
5 / 32
AIR QUALITY REQUIREMENTS
The air supplied into the device must be clean and dry. Even though the device is provided
with a filter, the presence of dust, oil or impurities may cause malfunction.
Air quality requirements according to ISO standard 8573
The air must be clean and dry.
The presence of impurities, oil or humidity in the air may cause deterioration which will not
be covered by the warranty.
When the instrument is working in vacuum conditions, impurities must be prevented from
being drawn into its internal components.
For this purpose we strongly recommend that a suitable airtight filter is installed between
the part under test and the instrument.
ATEQ recommends the following characteristics for the air supplied into the device.
Air characteristics ISO standard 8573 class
Grain size and concentration 0.1 μm and 0.1 mg/m3 Class 1
Dew point under pressure - 40°C dew Class 2
Maximum concentration of oil 0.01 mg/m3 Class 1
Recommended additional equipment
ATEQ recommends the installation of this additional equipment:
— Air dryer to provide dry air at less than -40°C dew point
— 25 micron and 1/100 micron double filter.

QSG_F6CLASS.376.00_EN_01 / 2019-03-25
6/32
Preamble
ATEQ F6CLASS, A UNIVERSAL LEAK TESTER
ATEQ F6Class is a leak detector that tests the airtightness of parts.
ATEQ F6Class can memorise16different test programs.
LEAK TEST
Direct measurement principle
The part under test3and the reference
part5are filled to an identical pressure.
A differential sensor4measures the pressure
variation between the part under test3and
the reference part5. In some applications,
the reference part can be replaced by a cap.
1Device
2Pressure sensor
3Part under test
4Differential pressure sensor
5Reference part

QSG_F6CLASS.376.00_EN_01 / 2019-03-25
7 / 32
PRINCIPLE OF A CYCLE
The measurement cycle is made of 4 main phases: fill, stabilization, test, dumping.
Pressure
(0) (1) (2) (4)
Time
Cycle start
Cycle end
(3)
0Waiting phase
1Fill phase
2Stabilization phase
3Test
4Dumping

QSG_F6CLASS.376.00_EN_01 / 2019-03-25
8 / 32
Your ATEQ F6Class
FRONT PANEL
1Display
2Cycle keys
3Navigation keys
4USB connectors
5Quick connector
6Mechanical Regulator
For more information, refer to User interface

QSG_F6CLASS.376.00_EN_01 / 2019-03-25
9/32
CONNECTORS ON THE BACK PANEL (WITH ALL OPTIONS)

QSG_F6CLASS.376.00_EN_01 / 2019-03-25
10/32
Ref Name Description
1J10 Not operational
2J12 Printer RS232 connector / Modbus (option)
3RReference part connector
4-Exhaust output
5-Input connector to the air filter (valves or regulator air supply)
6-Pilot pressure input or test pressure input (according
configuration)
7BPneumatic output for B automatic connector option
8APneumatic output for A automatic connector option
9-Vacuum input or external regulated pressure (according
configuration)
10 -Part number / Serial number
11 -Air supply energy information
12 P1 Pressurization output
13 TTest part connector
14 -Ground
15 J11 Relay board connector (digital inputs/outputsand 24VDC-2A
power supply)
16 J7 Connector for 24VDC-2A
Indice
Altri manuali ATEQ Strumento di misura