AUDAC LCR700 Istruzioni per l'installazione e il funzionamento

PROFESSIONAL AUDIO EQUIPMENT
LCR Meter LCR700
User Manual & Installation Guide
LCR70
0
LCR Meter
AUDAC

AUDAC PROFESSIONAL AUDIO EQUIPMENT
User Manual & Installation Guide
AUDAC
http://www.audac.be

2
INTRODUCTION.....................................................................................................................................................................................................................3
ENVIRONMENT......................................................................................................................................................................................................................4
SAFETY REQUIREMENTS ..................................................................................................................................................................................................5
GENERAL INFORMATION .................................................................................................................................................................................................6
OVERVIEW PANEL................................................................................................................................................................................................................7
SPECIFICATIONS ..................................................................................................................................................................................................................8
CAPITANCE ......................................................................................................................................................................................................................8
INDUCTANCE..................................................................................................................................................................................................................10
IMPEDANCE ....................................................................................................................................................................................................................12
GETTING STARTED ............................................................................................................................................................................................................13
1. AUTO POWER-DOWN................................................................................................................................................................................................13
2. FREQUENCY SELECT ...............................................................................................................................................................................................13
3. PARALLEL/SERIES MODE .......................................................................................................................................................................................13
4. RANGE BUTTON ........................................................................................................................................................................................................13
5. L/R/C FUNCTION BUTTON (ONLY MAIN DISPLAY) ..........................................................................................................................................14
6. Q/D/R FUNCTION BUTTON (ONLY SECOND DISPLAY) ...................................................................................................................................14
7. HOLD > 2SEC........................................................................................................................................................................................................14
8.MIN/MAX BUTTON .....................................................................................................................................................................................................14
9. SET ................................................................................................................................................................................................................................15
10. REL RELATIVE MODE (ONLY MAIN DISPLAY) ...............................................................................................................................................16
11. HI/LO LIMITS.............................................................................................................................................................................................................16
12. TOL .............................................................................................................................................................................................................................16
MAINTENANCE....................................................................................................................................................................................................................17
ADDITIONAL INFORMATION RS-232 COMMAND TABLE .....................................................................................................................................18
PERSONAL NOTES ..............................................................................................................................................................................................................22
Index

3
Introduction
Dear customer,
With the LRC Meter you have acquired a high-quality and state-of-the-art measurement appliance.
The device is essential to sound engineers because of its many possibilities. Users can carry out measurements
for induction, capacitance and impedance. During this action you can get a read-out on the D factor
(dissipation factor) on a second display. All measurements can be carried out on two different frequencies: 120
and 1.000 Hz. This allows a measurement of great accuracy.
The LCR700 has an Auto-Power OFF function, which helps conserve the lifespan of the battery, and a fuse
detection function to inform that a fuse is open or damaged. The use of a DC adapter can also serve to disable
the Auto Power OFF function. The RS232 port enables you to communicate with a computer.

4
Environment
Do not place the unit in environments which contain high levels of dust, heat, moisture or vibration.
Do not use the unit near water or other liquids. Make sure no water or other liquids can be spilled,
dripped or splashed on the unit.
This unit is developed for indoor use only. Do not use it outdoors.
Do not place objects on top of the unit.
Place the unit on a stable base.
Chapte
r
1

5
Safety Requirements
(Read the safety requirements before using the meter)
Warning:
Before taking any measurements, please isolate the DUT from the power supply.
You should remove the test leads from the meter before replacing the batteries in order to avoid an electric
shock. Make sure the circuit switch is disconnected before taking any measurements.
Do not use the meter if test leads look damaged. Please check regularly.
Caution:
When you can’t turn on the meter…
1. When you have turned off the meter a few seconds ago, it is perfectly normal. Please wait a moment to turn
it on again.
2. When you can’t operate the meter properly, please turn it off and restart later.
3. When the segments are fading away gradually, please wait 10 seconds to restart the meter.
4. When you can’t turn on the meter normally, please press the power key for 10 seconds and the meter will
restart.

6
General information
Display L\C\R-4 ½ digits, max. reading of 19999.
Q\D\R-4 digits, max.. reading of 9999 (Auto
range)
Measurement parameters Ls + (Q, D, Rs), Lp + (Q, D, Rp).
Cs+(Q,D,Rs),Cp+(Q,D,Rp).
Basic accuracy 0.5% for Impedance
0.7% for Inductance, Capacitance
Measuring range control Auto & manual
Overload indication “OL” display.
Test frequency 1KHz & 120 Hz
Low battery indication The indicator is displayed when the battery
voltage drops below the operating level and it
cancels all the memorized values to store into
EEPROM (included SET values).
Measurement speed once per second, nominal.
Operating environment 0°C to 50 °C at < 80% RH..
Storage environment -20°C to 60°C at 0 to 80% RH. With battery
removed from meter.
Power Single standard 9 Volt battery (NEDA 1604,
IEC 6F22 006P)
External power Adaptor 12 Volt min to 15 Volt max/50mA
(optional)
Auto power Auto power of if unused for 10 minutes
FUSE warning Indicates when a fuse is open of damaged.
Protective Fuse 0.1 A fast-blow 250V AC.
Dimensions 19.2 cm (Height), 9.1 cm (width), and 5.25 cm
(thickness).
Weights 365g (battery and holster included).
Accessories A pair of test leads, instruction manual, Software,
Optical data cable (9V battery and spare fuse in the
meter).
Chapte
r
2

7
Overview panel
APO Auto power off
RS232 Communication indicator
R Recording mode indicator
MAX Maximum reading indicator
MIN Minimum reading indicator
AVG Average reading indicator
AUTO Autoranging indicator
H Data hold indicator
SET Set mode indicator
Relative mode indicator
TOL Tolerance mode indicator
PAL Parallel mode indicator
SER Series mode indicator
D Dissipation factor indicator
Q Quality factor indicator
R Parallel or Series Resistance
indicator
% Tolerance indicator (percentage)
1 KHz Frequency indicator
120 Hz Frequency indicator
LRC L, C or R function indicator
High limit and tolerance indicator
Low limit and tolerance indicator
Low battery indicator
Beep tone indicator for tolerance
mode
MKΩImpedance (Ohm) indicator
umH Inductance (Henry) indicator
munpF Capacitance (Farad) indicator

8
Specifications
CAPACITANCE:
Test Frequency 120 Hz
Range Min. Max. Cx DF Note
20mF 1µF 10.000mF +/- (5.0%rdg +
5counts)
DF<0.1
+/- (10%rdg +
100/Cx + 5counts)
DF< 0.1
After short cal.
2000µF 100nF 1999.9µ +/- (1.0%rdg + 5
counts)
DF<0.1
+/- (2.0%rdg +
100/Cx + 5counts)
DF<0.1
After short cal.
200µF 10nF 199.99µF +/- (0.7%rdg + 3
counts) DF<0.5 +/- (0.7%rdg +
100/Cx + 5 counts)
DF<0.5
-
20µF 1nF 19.999µF +/- (0.7%rdg +
3counts) DF<0.5 +/- (0.7%rdg +
100/Cx + 5counts)
DF<0.5
-
2000nF 100pF 1999.9nF +/- (0.7%rdg +3counts)
DF<0.5 +/- (0.7%rdg +
100/Cx + 5counts)
DF<0.5
-
200nF 10 pF 199.99nF +/- (0.7%rdg + 5
counts) DF<0.5 +/- (0.7%rdg +
100/Cx + 5counts)
DF<0.5
After open cal.
20nF 1pF 19.999nF +/- (1.0%rdg +
5counts) DF<0.1 +/- (2.0%rdg +
100/Cx + 5 counts)
DF<0.1
After open cal.
Chapte
r
3

9
TestFrequency1KHz
Range
Min. Max. Cx DF Note
2000µF 100nF 1000.0µF +/- (5.0%rdg + 5counts)
DF<0.1
+/- (10%rdg + 100/Cx + 5
counts) DF<0.1
After short
cal.
200µF 10nF 199.99µF +/- (1.0%rdg+ 3counts)
DF<0.5 +/- (2.0%rdg + 100/Cx
+5counts) DF<0.5
After short
cal.
20µF 1nF 19.999µF +/- (0.7%rdg +3counts)
DF<0.5
+/- (0.7%rdg + 100/Cx +
5counts) DF<0.5
-
2000nF 100pF 1999.9nF +/- (0.7%rdg +3counts)
DF<0.5)
+/- (0.7%rdg + 100/Cx +
5counts) DF<0.5
-
200nF 10pF 199.99nF +/- (0.7%rdg +5counts)
DF<0.1
+/- (0.7%rdg + 100/Cx +
5counts) DF<0.5
-
20nF 1pF 19.999nF +/- (0.7%rdg + 100/Cx
+5counts) DF<0.1
+/- (0.7%rdg + 100/Cx +
5counts) DF<0.1
After open
cal.
2000pF 0.1pF 1999.9pF +/- (1.0% rdg+5counts) +/- (2.0%rdg+ 100/Cx +
5counts) DF<0.1
After open
cal.
Indice
Altri manuali AUDAC Strumento di misura