Auper TM6400 Guida all'installazione

Installation and programming guide
TM6400
64 CHANNELS FLOW MONITORING SYSTEM
AND TRANSMITTER

GENERAL INFORMATION
FCC INFORMATION
This device complies with Part 15 of FCC rules. Operation is subject
to the following two conditions:
(1) This device may not cause harmful interference and, (2) this
device must accept any interference received including interference
that may cause undesired operation.
Note: The user is cautioned that any changes or modifications not
expressly approved by the party responsible for FCC compliance
could void the user’s authority to operate the equipment.
No part of this publication may be reproduced, transmitted,
transcribed, stored in a retrieval system, or translated into any
language in any form by any means without the written permission of
Auper Electronic Controls Inc.
LIMITED 5YEAR WARRANTY
Auper Electronic Controls Inc. warrants that this product is in good
working condition, according to its specifications at the time of the
shipment, for a period of FIVE (5) years from the date of purchase.
Should the product, in Auper Electronic Controls Inc opinion,
malfunction within the warranty period, Auper Electronic Controls Inc.
will repair or replace the product without charge. Any replaced parts
become the property of Auper Electronic Controls Inc. This warranty
does not apply to the software component of a product or a product
which has been damaged due to an accident, misuse, abuse,
improper installation, usage not in accordance with product
specifications and instructions, natural or personal disaster or
unauthorized alterations, repairs or modifications.
THIS WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT (AT
AUPER’S OPTION) ONLY AND DOES NOT INCLUDE ANY LABOR
OR TRANSPORTATION CHARGES OR COMPLIANCE WITH ANY
FEDERAL, STATE OR LOCAL LAWS, CODES OR REGULATION.

TM600 FLOW TOTALIZER AND TRANSMITTER
2|P a g e
Notice of any claimed breach of said Warranty must be promptly given
to the Auper authorized dealer from whom the product was purchased
or leased. Upon request, all systems or parts which are claimed to be
defective must be made available for inspection by and/or return to (at
AUPER’S option) such authorized dealer and/or Auper. No repair or
replacement under said warranty will extend the original warranty
period.
THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER
WARRANTIES, ORAL OR WRITTEN, EXPRESS OR IMPLIED,
INCLUDING THE WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR ANY PARTICULAR PURPOSE.
LIMITATIONS
All warranty for this product, expressed or implied, are limited to five
years from the date of purchase and no warranty, expressed or
implied, will apply after that period. No warranties for this product
expressed or implied will apply to any person who purchases the
product in used condition. The liability of Auper Electronic Controls
Inc. with respect to any defective product will be limited to the repair
or replacement of such product.
In no event shall Auper Electronic Controls Inc be responsible or liable
for any damages arising
(a) from the use of the product;
(b) from the loss of use, revenue or profit of the product; or
(c) as a result of any event, circumstances, action or abuse beyond
the control of Auper Electronic Controls Inc.; whether such damage be
direct, indirect, consequential, special or otherwise and whether such
damages are incurred by the person to whom this warranty extends or
a third party.

DISCLAIMER OF OTHER WARRANTIES AND LIABILITIES
While all reasonable care has been taken in preparation of this
product, it is provided “as is,” without warranty as to performance or
fitness except as expressly stated above. The entire risk as to the
quality of output developed with this product is assumed by the user.
Auper Electronic Controls Inc does not warrant that the software or
system will meet any particular requirements of the user, other than
as expressly stated above, and specifically denies any liability for
incidental or consequential damages resulting from the use of this
software or system.
Auper Electronic Controls Inc also specifically denies all liability for
any technical or editorial omissions in its product documentation, and
for any incidental or consequential damages resulting from the
furnishing, performance or use of its documentation.

TM600 FLOW TOTALIZER AND TRANSMITTER
TM6400 Installation & User guide 4|P a g e
TM6400
Real-time flow monitoring system
Package
TM6400 control unit
12 Volts DC transformer @ 1.5 amp min
Flow meter collector box (1 of 4)
25 ft (7.62 m) flow meter collector cable
10 ft (3 M) serial cable or Cat 5 network cable
OPTIONAL
WiFi adapter
USB to serial adapter
Serial printer
Draft Manager Live software

TM6400 FLOW MONITORING SYSTEM
TM6400 Installation & User guide 5|P a g e
INSTALLATION
POSITIONING YOUR SYSTEM
The TM6400 being a control system, should receive the same
installation considerations as an alarm system. It should be installed
in such a way as to be tamper proof that you choose to install it at the
bar, outside the beer cooler or, in the manager’s office. Cables and
connections should be protected and secured out of reach. The
power source should not be installed where it can easily be
disconnected. Do not connect the TM6400 power source to an
electrical outlet that can be turned off at night.
COMMUNICATION
The TM6400 is equipped with two programmable serial ports and an
Ethernet adapter to connect it to a computer network.
The RS-422 port serial port connector is a RJ11 jack (phone jack).
The RS-232 port connector is a Dsub 9 pin connector (male)
RS-422 SPECIFICATIONS
Standard EIA RS-422 Physical Media Twisted Pair Network
Topology Point-to-point
Maximum Distance RS-422 1000 metres (3000 ft)
Mode of Operation Differential
Maximum Baud Rate RS-422 115.2 Kbytes

TM600 FLOW TOTALIZER AND TRANSMITTER
6|P a g e
Voltage Levels −6V to +6V (maximum differential Voltage)
Mark(1) Negative Voltages
Space(0) Positive voltages
Available Signals Tx+, Tx-, Rx-, Rx+ (Full Duplex)
RS-422 connector type RJ11
Using RS-422 and the Auper AP821 RS-422 eight port hub,
you can link several Auper metering systems to the same RS-
232 serial port or USB port of a computer or printer.
RS-232 SPECIFICATIONS
The RS-232 port can be used with one system connected directly to a
serial port of a computer running with the Draft manager software.
Maximum distance RS-232 15.25 metres (50 ft) with straight
cable or 44 metres (147 ft) using UTP Cat 5 cable
RS-232 connector type DB9 male
Maximum Baud Rate RS-232 115kbit/s
ETHERNET ADAPTER
The TM6400 is available with an optional Ethernet adapter you can
use to connect one, or several TM6400, directly to your computer
network to use the Draft Manager Live software. Once connected to a
network port, the adapter can be found and configured by remote
login by our technicians from any PC on the same network. This is
done at the same time as the software installation.
The system is also equipped with a real-time interface. The TM6400
will send the amount served through the Ethernet or serial port two
seconds after the flow meter has stopped recording following a
special communication protocol. To use this feature, you must use the
Draft Manager Live software.

TM6400 FLOW MONITORING SYSTEM
TM6400 Installation & User guide 7|P a g e
RED LED POWER FAIL INDICATOR
The red LED on the TM6400 will flash to signal that there was a
power failure. To stop the LED from flashing you will need to enter
your administrator code.
CONNECTING THE FLOW METERS
Follow the instruction sheet supplied with the flow meters for complete
step by step instructions on how to install the flow meters. Videos are
also available on the Auper YouTube channel accessible from the
web site. The flow meters will be connected to one or 4 flow meter
collector box. The collector boxes are designed to be mounted in beer
coolers. Since the flow meters are supplied with a 25 ft (7.6 M) cable,
you should try to position each collector box in the beer cooler to
reach as many flow meters as possible. Flow meter cables can be
extended should you need to.
WARNING:
The power to the collector boxes comes from the TM6400 through the
collector cables. Always disconnect the power to the TM6400 when
working on the collector(s) or, when connecting or disconnecting the
collector cables.
Figure 1 TM6400 Collector box

TM600 FLOW TOTALIZER AND TRANSMITTER
8|P a g e
One collector box is able to take
up to 16 flow meters. Up to four
collector boxes can be connected
to one TM6400 for a total of 64
flow meters per system.
You will connect the collector
boxes to the TM6400 using a
regular Cat 5 network cable
terminated with RJ45 connectors.
Cables are available for up to 150
ft (46M). Longer cables can be made on demand and can reach 300 ft
(100 M). This is the same kind of cables used for computer networks.
You can find them in computer stores or have them installed by local
computer network contractors. However, you must not connect the
collector cables to the computer network and each cable should
be tested priot to connecting it to the collector and TM6400
system..

TM6400 FLOW MONITORING SYSTEM
TM6400 Installation & User guide 9|P a g e
There are two channels on the TM6400 each able to take one or 2
collector boxes. Channel 1 on the TM6400 (flow meters No.1 to 32)
will take one or two collector boxes. The second collector boxe (flow
meter 17 to 32) connects to the first collector box using the OUT
connector to the IN connector of the first collector box. The same
goes with channel 2 for flow meters 33 to 64.
The ends of flow meter cables have been stripped at the factory. Twist
the wire and then pull the insulation off the wire. Cut the copper wire
to get ¼ in (6mm) exposed only.
Auper flow meters do not need an external power source. There is no
voltage going to the flow meters so you cannot damage them even if
you touch the wires. There is no positive or ground either. You do not
have to worry about polarities.