Avaya LUPCMALL Guida

PCM Paging Control System
Installation and Use Manual
© 2004 Bogen Communications, Inc.
All rights reserved. 54-2011-01D 1011
Model: LUPCMALL
PEC Code: 5323-106
COM Code: 408186013
Select Code: 701-000-109
Issue 4, November 2010

Notice
Every effort was made to ensure that the information in this
guide was complete and accurate at the time of printing.
However, information is subject to change.
FCC Statement (Part 15) - Radio Frequency
Interference
The PCM Paging Control System generates and uses radio
frequency energy and, if not installed and used in strict
accordance with the manufacturer's instructions, may cause
interference to radio and television reception. This equipment
is component registered with the Federal Communications
Commission (FCC) in accordance with Part 15 of its rules and
Canadian D.O.C. regulations. However, there is no guarantee
that interference will not occur in a particular installation. If this
equipment does cause interference to radio or television
reception, which can be determined by turning the PCM Paging
Control System unit off and on, the user is encouraged to try
to correct the interference by one or more of the following
measures:
- Reorient the radio or TV receiving antenna.
- Relocate the PCM Paging Control System unit with respect to
the radio or TV receiver or vice-versa.
- Plug the PCM Paging Control System unit into a different
outlet so that it and the radio or TV receiver are on different
branch circuits.
If necessary, the user should consult the dealer or an
experienced radio/television technician for additional
suggestions. The user may find the following booklet, "How To
Identify and Resolve Radio-TV Interference Problems," helpful. This
booklet was prepared by the Federal Communications
Commission (FCC) and is available from the U.S. Government
Printing Office, Washington, DC 20402. Stock order No. 004-
000-00345-4.
Federal Communications Commission (FCC)
Statement (Part 68)
This equipment is component registered with the Federal
Communications Commission (FCC) in accordance with Part
68 of its rules. In compliance with the rules, be advised of the
following:
Registered equipment may not be used with Coin Telephone
Lines. Equipment may be used with Party Lines in areas where
state tariffs permit such connections and when equipment is
adaptable for such service.
This equipment is registered as follows:
Registration Number - CD2KOR-74854-PA-N
Ringer Equivalence - 1.0B
If trouble is experienced, the equipment should be disconnected
from the interface to determine if this equipment, or the
telephone line, is the trouble source. If the equipment is
determined to be malfunctioning, it should not be reconnected
until repairs are effected.
Repairs to this equipment, other than routine repairs, can be
made only by the manufacturer or its authorized agents.
If the equipment causes harm to the telephone network, the
local telephone company may temporarily discontinue your
service and, if possible, notify you in advance. If advance notice
is not practical, you will be notified as soon as possible. You will
be given the opportunity to correct the problem and informed
of your right to file a complaint with the FCC.
The local telephone company may make changes in its facilities,
operations, or procedures that could affect the proper
functioning of your equipment. If they do, you will be given
adequate notice in writing to allow you an opportunity to
maintain uninterrupted telephone service.
Important Safety Information
Always follow these basic safety precautions when installing and
using the system:
1. Read and understand all instructions.
2. Follow all warnings and instructions marked on the
product.
3. DO NOT block or cover the ventilation slots and
openings. They prevent the product from overheating. DO
NOT place the product in a separate enclosure or cabinet,
unless proper ventilation is provided.
4. Never spill liquid on the product or drop objects into the
ventilation slots and openings. Doing so may result in
serious damage to the components.
5. Repair or service must be performed by a factory
authorized repair facility.
6. The product is provided with a UL-CSA approved, 3-wire
ground type plug. This is a safety feature. DO NOT defeat
the safety purpose of the grounding type plug. DO NOT
staple or otherwise attach the AC power supply cord to
building surfaces.
7. DO NOT use the product near water or in a wet or damp
place (such as a wet basement).
8. DO NOT use extension cords. The product must be
installed within 6 feet of a grounded outlet receptacle.
9. DO NOT install telephone wiring during a lightning storm.
10. DO NOT install telephone jacks in a wet location unless
the jack is specifically designed for wet locations.
11 Never touch uninsulated wires or terminals, unless the line
has been disconnected at the paging or controller interface.
12. Use caution when installing or modifying paging or control
lines.
Support Information
Paging systems integrated with small phone systems such as
Merlin Legend and Partner are supported by the National
Service Assistance Center (NSAC). The main number for the
NSAC is 800-628-2888. Paging systems integrated with large
switches such as the DEFINITY G3 are supported by the
Technical Service Center (TSC). The main number for the TSC
is 800-242-2121.
© 2004 Bogen Communications, Inc.
All Rights Reserved.

[3]
Contents
1. Introduction..........................................................................................................................5
1.1. Voice Channel ........................................................................................................5
1.2. Background Music ..................................................................................................6
1.3. Signaling Channel ..................................................................................................6
1.4. Other Features ........................................................................................................6
2. Before You Start ..................................................................................................................7
2.1. Select Options..........................................................................................................7
2.2. Package Contents ....................................................................................................7
3. Installation............................................................................................................................9
3.1. Adding PCMZPM Modules ....................................................................................9
3.2. Mounting the PCM System ....................................................................................9
3.2.1. Wall Mounting ........................................................................................................9
3.2.2. Rack Mounting ........................................................................................................9
4. LUPCMALL Feature Callouts ..........................................................................................11
5. System Wiring Connections................................................................................................13
5.1. Telephone System Connections ..............................................................................13
5.2. PBX Loop Start Trunk Port ....................................................................................13
5.3. PBX Ground Start Trunk Port ................................................................................14
5.4. PBX Page Port ........................................................................................................15
5.5. PBX Analog Station Port ........................................................................................15
5.6. Night Ringer ............................................................................................................16
5.7. Override Input ........................................................................................................17
6. Paging Amplifier Connections............................................................................................19
7. Background Music ..............................................................................................................21
7.1. Helpful Hints When Connecting Background Music to the
Paging Control System............................................................................................21
7.2. Background Music Continuously Supplied To All Zones Not Being Paged ........23
7.3. Background Music Supplied By Same Amplifier That Supplies
Paging, Music Input Available On Amplifier ........................................................23
7.4. Background Music Supplied by Same Amplifier Supplying Paging,
No Dedicated Music Input Available On Amplifier ..............................................23
7.5. Background Music Or Different Background Music Supplied
To A Select Group Of Zones ..................................................................................23
7.5.1. Zone Modules Working With 70V Speakers..........................................................23
7.5.2. Zone Modules Working With Self-Amplified Speakers ........................................23
7.6. Inhibiting Background Music In Select Zones ......................................................23
8. Zone Speaker Wiring and Setup ........................................................................................29
8.1. Wiring to 70V speakers ..........................................................................................29
8.2. Wiring to Self-Amplified Speaker or Dedicated Amplifier....................................29
8.3. Setting a Zone for Talk Back Operation ................................................................29

[4]
9. Optional Wiring ..................................................................................................................33
9.1. CPU to Emergency Signaling ................................................................................33
9.2. CPU to Re-Synch (Master Clock) ..........................................................................33
9.3. Relay Drivers ..........................................................................................................33
10. Power-Up of PCM and Associated Equipment ................................................................35
10.1. Power-Up Sequence ................................................................................................35
10.2. Priority Order ..........................................................................................................35
11. System Programming ..........................................................................................................37
11.1. Programming Paging Zone Groups ........................................................................38
11.1.1. To Erase A Zone Paging or Signaling Group ........................................................38
11.2. Programming Signaling Zone Groups ....................................................................38
11.3. Interface Default Timer ..........................................................................................38
11.4. Interface VOX Timer ..............................................................................................38
11.5. Dialing Timeout ......................................................................................................38
11.6. Single Amp BGM....................................................................................................39
11.7. Programming Real Time Clock ..............................................................................39
11.7.1. Clock Synchronization ............................................................................................39
11.8. Time-Triggered Events............................................................................................39
11.9. Setup Tone ..............................................................................................................39
11.10. Reset Default Values ..............................................................................................39
11.11. Relay Contacts ........................................................................................................39
12. Feature Codes and Defaults................................................................................................41
13. Paging: How To Use The PCM ..........................................................................................45
13.1. Paging Zones ..........................................................................................................45
13.2. How To Page Zones ................................................................................................45
13.3. How To Make An All-Call Page ............................................................................45
13.4. How To Page A Zone Group ..................................................................................45
13.5. How To Make A Code Call ....................................................................................46
13.6. How To Make A Pattern Code Call........................................................................46
13.7. How To Make An Echo Code Call ........................................................................47
14. Testing and Troubleshooting ..............................................................................................49
Appendix A: Applications............................................................................................................53
Appendix B: Tones ......................................................................................................................59
Appendix C: Glossary of Programmable Features ..................................................................61
Appendix D: Configuration Forms ............................................................................................63

[5]
1. Introduction
PCM
TIM
PCM
CPU
PCM
TBM
PCM
ZPM
Figure 1-1: LUPCMALL Paging System Control Assembly
The PCM Paging Control System (see Figure 1-1) is an expandable zone paging and signaling system. The LUPCMALL
consists of 4 pre-assembled modules: PCMTIM, PCMCPU, PCMTBM, and a Zone Paging Module (PCMZPM). To this, you
can add up to two additional Zone Paging Modules (Model: LUPCMZONE, Pec Code 5323-108, Com Code 408186039) to
increase system zone paging capacity to 9 zones.
If more than 9 zones are required, expansion assemblies (Model: LUPCMADD, Pec Code 5323-107, Com Code 408186021)
can be added up to a total capacity of 99 zones in 3 zone increments. Expansion assemblies include a PCMCPU and a
PCMZPM.
The Paging Control System provides the following features and functions:
1.1. Voice Channel
• Zone Paging & sub zone group paging (up to 32 zone groups, each with up to 99 zones)
• Override paging (using loop start or contact closure)
• Talk Back paging (centrally-amplified zones only)
• Talk/Talk Back selection per zone
• High/Low-powered central paging
• High/Low-powered distributed paging
• Privacy Beep on talk back zones
• Pre-Announce Tone

[6]
1.2. Background Music
• High/Low-Powered distributed (buffered for up to 50 amplified speakers)
• High/Low-Powered, using dedicated BGM amplifier
• High/Low-Powered using a single paging/BGM amplifier
• BGM Disable to individual zones
• Local BGM input on each individual zone module
1.3. Signaling Channel
• Night Ringer (90V or contact closure activation)
• Code Calling (2 types - echo & pattern)
• Emergency/Shift Change Tone (tone and duration selectable)
• Specialized modules provide Time-Triggered signaling
1.4. Other Features
• DTMF setting of all operating parameters
• Run/Program switch
• External C-form contacts
• Relay Driver output per zone
• Non-volatile memory for setup data (no backup battery required)
• Setup Tone to assist in volume setting, etc.
• Synchronization to external master clocks

[7]
2. Before You Start
2.1. Select Options
Before setting up your system, use the checklist below to assist you in setting up and programming the PCM Paging
Control System.
____ Type of Telephone Interface (loop start, ground start, page port, station port)
(see System Wiring Connections, Section 5)
____ Total Number of Paging Zones (additional Zone Paging Modules or LUPCMADD Paging Control System
Assemblies may be required) (see Installation, Section 3)
____ Zone Groups (see Section 11.1)
____ Time-Triggered Signaling (see Sections 11.2 and 11.8):
____ Signaling Zone Groups (see Sections 11.2 and 11.8)
____ Clock Synchronization (see Section 11.7.1)
____ All-Call Capability (see Section 11.1)
____ Code Calling Capability (see Section 11.2)
____ Background Music (see Section 7):
____ Continuous in Zones Not Being Paged (see Section 7.2)
____ Cease in All Zones During Page (see Sections 7.3 and 7.4)
____ Inhibited in Some Zones (see Section 7.6)
____ Different in Some Zones (see Section 7.5)
____ Night Ring Capability (see Section 5.6)
____ Override Capability (see Section 5.7):
____ From Telephone/Loop Start Trunk (see Section 5.2)
____ From External Audio Equipment (see Appendix A)
2.2. Package Contents
• 4 pre-assembled modules - PCMTIM, PCMCPU, PCMTBM, and PCMZPM
• Power Supply
• Rack Mount brackets (2)
• Installation and Use Manual
• Screws

[8]
Figure 3-1: Rack Mounting the LUPCMALL Paging Control System

[9]
3.1. Adding PCMZPM Modules
The LUPCMALL is pre-assembled to accommodate 3 zones of paging. If your installation requires 4 to 9 zones, you can add
one or two Zone Paging Modules (PCMZPM). A total of 3 PCMZPM modules (9 zones total) can be used on a LUPCMALL
assembly. If your installation requires more than 9 zones, you will need one or more LUPCMADD units to allow system
expansion beyond 9 zones. Install the extra PCMZPM modules before mounting and wiring the PCM System assemblies.
(Refer to the LUPCMZONE installation manual.)
NOTE: LUPCMADD Paging Control System Expansion Assemblies and Zone Paging Modules can only be added when the
previous assembly contains 3 PCMZPM modules; otherwise, the system will not operate.
3.2. Mounting the PCM System
The Paging Control System Assemblies can be either wall- or rack-mounted.
3.2.1. Wall Mounting
1. After assembling the unit (if necessary) hold the unit level against the surface to which it will be mounted.
2. Mark where the mounting screws should be positioned.
3. Set the assembly aside and install the screws leaving about ¼" of the screw sticking out of the surface.
4. Slip the assembly over these screws and tighten them snuggly.
3.2.2. Rack Mounting
1. Position the left side of the completed PCM assembly (any additional PCMZPM modules should have already been
added) over one of the rack mounting adapters. Refer to Figure 3-1 and use the correct holes for the number of modules
in the assembly (4, 5, or 6 as shown).
2. Secure the left side of the PCM system to the rack adapter using two of the truss head sheet metal screws.
3. Secure the right side of the PCM system to the other rack adapter using the holes for the number of modules in the
assembly and the remaining 2 truss head sheet metal screws.
4. Secure the assembly to a 19" rack (rack screws not supplied).
3. Installation

[10]
PCM
TIM
PCM
CPU
PCM
TBM
PCM
ZPM
Figure 4-1: LUPCMALL Feature Callouts