02-03-2015
584 M0 01 F Page 2
MOUNTING
The indicator exceeds very widely the summit of the tank, it is necessary to make sure that there is enough space to take it up.
The indicator is linked to the tank by DN65 flange connection (F 4 model) or 2’’ threated connection (F 4 Fût model)
For contact adding or any option, please refer to owner’s manual of those device .The F 4 indicator is ready since its mounting
on the tank. The float follows level raising and the colored indicator shows level position on upper part of the device. To avoid
any overpressure which could prevent the float to go up, two little holes are located under the fixating flange.
MAINTENANCE
F 4 is a robust level indicator; it does not require specific maintenance. From time to time, clean the float and back face of tube.
TECHNICAL FEATURES
Float: PPH or PVC
tem: PPH or PVC
Guiding tube: PPH or PVC
Indicator: PPH/PVC or PVC
Temperature maxima PVC: 60 °C
PPH: 80 °C
Maximal pressure: Atmospheric
OPTION: Level switches B M 501
or BRK 60/32
Standard odel
Maximal height: 3000 mm, depending of fluid specific weight
Mounting: Loose flange ND 65, in PPH or PVC
For dru s
Maximal height: 1000 mm, depending of fluid specific weight
Mounting: Thread 2” G, PVC or PPH
Metric buttress thread, PVC or PPH (other on request)