Bindicator Pulse Point II Series Manuale utente

Pulse PointTM II Series
Installation & Operation Manual
IOM
LVP180613 Rev. B
O
Or
rd
de
er
r
f
fr
ro
om
m:
:
C
C
A
A
B
Br
ri
ig
gg
gs
s
C
Co
om
mp
pa
an
ny
y
622 Mary Street; Suite 101; Warminster, PA 18974
Phone: 267-673-8117 -


Pulse PointTM II Series
Installation & Operation Manual
CONTENTS
I. HANDLING & STORAGE..................................................................................................................................................................1
Inspection and Handling
Disposal and Recycling
Storage
II. GENERAL SAFETY.............................................................................................................................................................................2
Authorized Personnel
Use
Misuse
III. PRODUCT DESCRIPTION ...............................................................................................................................................................3
Function
Applications
Features
Technical Specications
Approvals
IV. MECHANICAL INSTALLATION ......................................................................................................................................................5
Guidelines
Figure 1. Mounting Orientation
Figure 2. Mounting in Relation to Flow of Material
Figure 3. Index Mark Positioning
Mounting Considerations
V. ELECTRICAL INSTALLATION..........................................................................................................................................................7
General Safety
Disconnect Requirements for Permanently Installed Equipment
Protective Earth Ground
Conduit Cable Connection
Electrical Connections
LP II Series Integral Model Only
LP II Series Remote Model Only
Figure 4. LP II Series - Integral Enclosure with Cover Removed - STANDARD
Figure 5. LP II Series - Integral Enclosure with Cover Removed - ADVANCED
Figure 6. Power and Ground Connections
Figure 7. Main Relay Connections
Figure 8. Auxiliary Relay Connections - ADVANCED ONLY
Figure 9. LP II Series - Remote Enclosure with Cover Removed - STANDARD
Figure 10. LP II Series - Remote Enclosure with Cover Removed - ADVANCED
Figure 11. LP II Series Remote Connection Diagram

SAFETY SYMBOLS
WARNING:
IDENTIFIES CONDITIONS OR PROCEDURES, WHICH IF NOT FOLLOWED, COULD
RESULT IN SERIOUS INJURY. RISK OF ELECTRICAL SHOCK.
CAUTION:
IDENTIFIES CONDITIONS OR PROCEDURES, WHICH IF NOT FOLLOWED, COULD
RESULT IN SERIOUS DAMAGE OR FAILURE OF THE EQUIPMENT.
VI. SET-UP ........................................................................................................................................................................................... 15
Operation
Product Overview - STANDARD
Figure 12. Switch Functions, Standard
Product Overview - ADVANCED
Figure 13. Switch Functions, Advanced
Build Up Detection
Fail-Safe Selection
Figure 14. Fail-Safe Operation
Time Delay Settings - STANDARD
Time Delay Settings - ADVANCED
Sensitivity Settings - STANDARD
Sensitivity Settings - ADVANCED
Liquid/Solid Interface - ADVANCED ONLY
Test - ADVANCED ONLY
Figure 15. Magnetic Fob
VII. MAINTENANCE .............................................................................................................................................................................. 19
VIII. TROUBLESHOOTING .................................................................................................................................................................... 19
IX. DIMENSIONAL DRAWINGS ........................................................................................................................................................ 20

1
www.bindicator.com
LVP180613 Rev. B
Pulse Point II Series
Installation & Operation Manual
I. HANDLING AND STORAGE
SAVE THESE INSTRUCTIONS
INSPECTION AND HANDLING
Do not dispose of the carton or packing materials.
Each package should be inspected upon receipt for damage that may have occurred due to mishandling during
shipping. If the unit is received damaged, notify the carrier or the factory for instructions. Failure to do so may
void your warranty. If you have any problems or questions, consult Customer Support at 800-778-9242.
DISPOSAL AND RECYCLING
This product can be recycled by specialized companies and must not be disposed of in a municipal collection
site. If you do not have the means to dispose of properly, please contact for return and disposal instructions or
options.
STORAGE
If the device is not scheduled for immediate installation following delivery, the following steps should be
observed:
1. Following inspection, repackage the unit into its original packaging.
2. Select a clean dry site, free of vibration, shock and impact hazards.
3. If storage will be extended longer than 30 days, the unit must be stored at temperatures between
32º and 158º F (0º to 70° C) in non-condensing atmosphere with humidity less than 85%.
CAUTION: DO NOT STORE A NON-POWERED UNIT OUTDOORS FOR A PROLONGED PERIOD.

2LVP180613 Rev. B
www.bindicator.com
II. GENERAL SAFETY
AUTHORIZED PERSONNEL
All instructions described in the document must be performed by authorized and qualied service personnel
only. Before installing the unit, please read these instructions and familiarize yourself with the requirements and
functions of the device. The required personal protective equipment must always be worn when servicing this
device.
USE
The device is solely intended for use as described in this manual. Reliable operation is ensured only if the
instrument is used according to the specications described in this document. For safety and warranty
reasons, use of accessory equipment not recommended by the manufacturer or modication of this device is
explicitly forbidden. All servicing of this equipment must be performed by qualied service personnel only. This
device should be mounted in locations where it will not be subject to tampering by unauthorized personnel.
MISUSE
Improper use or installation of this device may cause the following:
• Personal injury or harm
• Application specic hazards such as vessel overll
• Damage to the device or system
If any questions or problems arise during installation of this equipment, please contact Customer Support at
800-778-9242.

3
www.bindicator.com
LVP180613 Rev. B
III. PRODUCT DESCRIPTION
FUNCTION
The LP®II Series units are electronic, vibratory level controls designed for use in powders and granular solids. A
vibrating “tuning fork” is used to sense the presence of material.
The tuning fork contains two piezoelectric crystal assemblies: one “transmit” and one “receive”. The Piezo
crystals convert electrical signals to mechanical movement, and vice versa. High-voltage DC is applied to the
transmit crystal cause the tines of the fork vibrate. This vibration is mechanically coupled to the receive crystal
which produces a small electrical signal. The receive crystal will produce low voltage as long as the fork is
vibrating.
If the fork stops vibrating, as it does when in contact with material in the vessel, the receive pulses stop. The
electronics recognize this loss of signal and cause the main relay to change state.
APPLICATIONS
Unlike radio frequency and capacitance technology sensors, the LP II Series devices sense material using a
mechanical principle and are therefore not aected by the dielectric constant of the material. These are ideal
sensors in plastics, dust, shavings, and low-density powders and food. Material as light as 0.5 lbs/ft3(8 kg/m3)
can easily be sensed. LP II can be used in any free owing dry material up to 3/8” (9.525 mm) in particle size.
FEATURES
Multiple mounting congurations, forks, and coatings available to suit almost any application
Universal input power; AC or DC (see specications for input ranges)
No calibration required
Adjustable time delay
Selectable fail-safe operation (high or low level)
Adjustable Sensitivity
Build-up Detection - ADVANCED ONLY

4LVP180613 Rev. B
www.bindicator.com
TECHNICAL SPECIFICATIONS
FUNCTIONAL
Power Requirements Universal (± 10%), 120-240 VAC 50/60 Hz or 24-48 VDC
Power Consumption - STANDARD 3 W AC; 3 W DC
Power Consumption - ADVANCED 4 W AC; 4 W DC
Fuse Fast Blow, 1 A 300 V (Not User Serviceable)
Operating Temperature
Electronics -40° to 158° F (-40° to 70° C)
Fork -55° to 302° F (-48° to 150° C) depending on fork
Outputs
Main Relay 8 A DPDT @ 240 VAC or 30 VDC (resistive)
Auxiliary Relay - ADVANCED ONLY 0.46 A SPDT @ 150 VAC or 1 A @ 30 VDC
PERFORMANCE
Pressure Rating 150 psi (10.5 kg/cm2) with 11/2" NPT; 5 psi (0.35 kg/cm2) with mounting plate
Time Delay - STANDARD Field Adjustable; 1-6 seconds
Time Delay - ADVANCED Field Adjustable; 0-150 seconds
Fail Safe Field Selectable; high/low level
Sensitivity - STANDARD Minimum 2.0 lbs/ ft3(32 kg/m3); Field Adjustable
Sensitivity - ADVANCED Minimum 0.5 lbs/ft3(8 kg/m3); Field Adjustable
Maximum Particle Size 3/8" (9.5 mm)
PHYSICAL
Enclosure Material Polyester or Epoxy Coated Aluminum or 304 SS
Fork Material 316 SS (standard); 316 SS with Teon®coating
Dual Conduit Entry 3/4” NPT or M20 x 1.5
Extended Pipe Material Galvanized or 316 SS
Shipping Weight Integral, non-extended 10 lb (4.5 kg)
Pollution Degree 2
Installation Category II
Altitude 6,562 ft (2,000 m)
APPROVALS & RATINGS
UL (US and Canada):
Ordinary Location Type 4X; IP66
Hazardous Location, Type 4X; IP66 (Pending)
Explosion Proof
Dust Ignition Proof
CE
Electromagnetic Compatibility Directive
Low Voltage Directive

5
www.bindicator.com
LVP180613 Rev. B
IV. MECHANICAL INSTALLATION
WARNING: VERY HIGH VOLTAGE IS PRESENT ON THE FORK TERMINALS.
REMOVE POWER FROM THE UNIT BEFORE INSTALLING, REMOVING, OR MAKING ADJUSTMENTS
GUIDELINES
The following precautions should be observed when installing and operating an LP II device:
• The installation and wiring of this product must comply with all national, federal, state, municipal and
local codes that apply.
• The LP II Series are precision devices - handle carefully to prevent damage to the forks.
• Do not allow moisture to enter the electronics enclosure. Conduit should slope downward from the LP II
housing. Install drip loops (or drain tting) and seal conduit with silicone rubber product.
• The resonant frequency of the forks is 85 Hz (±10%); locations subject to this vibration frequency should
be avoided.
CAUTION: ATTEMPTING TO TIGHTEN THE UNIT BY ROTATING THE HOUSING OR FORKS MAY
DAMAGE THE UNIT AND VOID THE WARRANTY.
CAUTION: WHETHER MOUNTING DIRECTLY THROUGH A SIDE WALL, OR PIPE EXTENDED AND
MOUNTED VERTICALLY THROUGH THE TOP OF A VESSEL, NEVER ATTEMPT TO MOUNT THROUGH
A FULL COUPLING.
The LP II unit must be located at the position where level indication is desired. The forks may be mounted
through the top or side wall of the vessel. To ensure reliable operation, observe the following guidelines when
choosing the mounting location.
• DO NOT mount the forks in an area where they can contact the vessel.
• The forks assembly must be horizontal or pointing downward. DO NOT mount the forks pointing upward.
• If the unit is to be used with powders, it should be installed vertically, or at a downward angle that
exceeds the angle of repose to reduce material build-up on the forks.
Figure 1. Mounting Orientation

6LVP180613 Rev. B
www.bindicator.com
CAUTION: THE MAXIMUM ALLOWABLE DOWNWARD FORCE ON THE FORKS IS 88 LBS 40 KG.
To calculate the maximum solids head height above a horizontally mounted fork, use the following equation:
Maximum height of material (ft) = 2200 / bulk density (lbs/ft3)
Do not mount the fork directly in the ow of material. If necessary, use a bae to protect the fork from falling
material. The bae should be placed 6 to 8 inches above the fork so that material will not become packed
between the fork and the bae.
If using a remote unit, remote turtle cannot be mounted more than 100 feet away.
Figure 2. Mounting In Relation To Flow of Material
If the fork is mounted horizontally, it must be positioned so that the material will not accumulate on top of the tines.
There is an index mark on the mounting nut to assist in proper positioning of the fork.
Figure 3. Index Mark Positioning
INDEXÊMARK
Altri manuali per Pulse Point II Series
1
Indice
Altri manuali Bindicator Strumento di misura

Bindicator
Bindicator PRD1000 Manuale utente

Bindicator
Bindicator VRF-2000R Series Manuale utente

Bindicator
Bindicator MP Series Manuale utente

Bindicator
Bindicator Roto-Bin-Dicator Manuale utente
Bindicator
Bindicator SonoTracker Ultrasonic Liquid Level Manuale utente

Bindicator
Bindicator Pulse Point LP-500ST Manuale utente