Blu Stream Multicast ACM200 Manuale utente

Blustream Multicast ACM200 / ACM210
Advanced Control Module
User Manual
MULTICAST
Revision 1.3 - August 2023
RS-232 NORMAL RESET 5V 12V
IO1
IO2
IO3
IO4
V OUT
IO LEVELMCU
ACM210
VIDEO LAN (PoE) CONTROL LAN IR CTRL
IR
5V 12V
LINKLINKPoE
12V 1A

ACM - Multicast Advanced Control Module USER MANUAL
02 www.blustream.co.uk / www.blustream.com.au / www.blustream-us.com
Surge protection device
recommended
This product contains sensitive electrical
components that may be damaged
by electrical spikes, surges, electric
shock, lightning strikes, etc. Use of
surge protection systems are highly
recommended in order to protect and
extend the life of your equipment.
Safety and performance notice
Do not substitute or use any other power
supply other than approved PoE network
products or approved Blustream power
supplies.
Do not disassemble the ACM200 unit
for any reason. Doing so will void the
manufacturer’s warranty.
Contents
Thank you for purchasing
this Blustream product
For optimum performance and safety,
please read these instructions carefully
before connecting, operating or adjusting
this product. Please keep this manual for
future reference.
Introduction 03
Features 03
Panel Descriptions - ACM200 / ACM210 04
Control Ports 05
Control Ports - IR Control 06
Network Connection - Schematic Diagram 07
Web-GUI - Sign In / Log In 08
Web-GUI - New Project Set-up Wizard 09 - 13
Web-GUI - Menu Overview 14
Web-GUI - Drag & Drop Control 15
Web-GUI - Video Wall Control 16
Web-GUI - Preview 17
Web-GUI - Project Summary 18
Web-GUI - Transmitters 19 - 21
Web-GUI - Receivers 22 - 23
Web-GUI - Fixed Signal Routing 24 - 26
Web-GUI - Video Wall Configuration 27 - 32
Web-GUI - Users 33 - 34
Web-GUI - Settings 35 - 36
Web-GUI - Update Firmware 37 - 39
Web-GUI - Update Admin Password 39
RS-232 Serial Routing 40
Specifications, Package Contents & Maintenance 41
Blustream IR, RS-232 & Telnet Commands 42 - 48
Troubleshooting 49
Computer Settings - enabling TFTP & Telnet 50 - 53

03
contact support@blustream.co.uk / support@blustream.com.au / support@blustream-us.com
ACM - Multicast Advanced Control Module USER MANUAL
Introduction
Impotant Note:
The Blustream Multicast system distributes HDMI video over managed network hardware. It is advised that Blustream
Multicast products are connected on an independent network switch (or VLAN) to prevent unnecessary interference, or
reduction in signal performance due to other network products bandwidth requirements.
Please read and understand the instructions in this manual and ensure that the network switch is configured correctly
prior to connecting any Blustream Multicast products. Failure to do so will result in problems with configuration of the
system and video performance.
• Web interface module for configuration and control of the Blustream Multicast system
• Intuitive 'Drag & Drop' source selection with video preview feature for active monitoring of system status
• Advanced signal management for independent routing of Video, Audio, IR, RS-232, and USB/KVM
• Auto system configuration
• 2x RJ45 LAN connections to bridge existing network to Multicast video distribution network, resulting in:
- Better system performance as network traic is separated
- No advanced network setup required
- Independent IP address per LAN connection
- Allows simplified TCP/IP control of Multicast system
• RS-232 integration for control of Multicast system
• IR integration for control of Multicast system
• PoE (Power over Ethernet) to power ACM from PoE switch
• Local 12V power supply (optional) should switch not support PoE
• Support for iOS and Android App control
• 3rd party drivers available for most control brands
The UHD Multicast distribution platform allows distribution of HDMI video over a 1Gb Network switch. The ACM200 &
ACM210 Advanced Control Modules (known as 'ACM' from this point forwards in this guide) allow advanced third party
control of the Multicast system using TCP / IP, RS-232 and IR.
The ACM includes a web interface module for control and configuration of the Multicast system and features 'Drag &
Drop' source selection with media preview and independent routing of Video, Audio, IR, RS-232, and USB / KVM.
Pre-built Blustream product drivers simplify Multicast product installation and negate the need for an understanding
of complex network infrastructures.
This User Guide covers the features and functionality for both the ACM200 and ACM210 Advanced Control Module
products from Blustream.
The ACM200 is currently used for IP50HD, IP200UHD and IP250UHD systems only.
The ACM210 can be used for individual IP50HD, IP200UHD, IP250UHD, IP300UHD and IP350UHD systems.
Please note: IP200UHD and IP250UHD systems are interoperable. IP300UHD and IP350UHD systems are interoperable.
The IP50HD is a standalone system and is not interoperabel with eithe rof the above 2 sets of Multciast systems.
Features

ACM - Multicast Advanced Control Module USER MANUAL
04 www.blustream.co.uk / www.blustream.com.au / www.blustream-us.com
VIDEO LAN (PoE) CONTROL LAN IR CTRL
IR
5V 12V
LINKLINKPoE
12V 1A
Front Panel
2
14
9
8
7
6
1RS-232 control port – connect to a third party control
device for control of the Multicast system using RS-
232.
2MCU Upgrade toggle - use when upgrading MCU
firmware only. Leave in normal position for
standard operation.
3Reset - short press resets the ACM, long press (10
seconds) factory defaults the ACM.
4IO Level switch - reserved for future use.
5IO Level phoenix - reserved for future use.
6Video LAN (PoE) - connect to the network switch that
the Blustream Multicast components are connected
to.
7Control LAN port - connect to existing network that
a third party control system resides on. The Control
LAN port is used for Telnet/IP control of the Multicast
system. Not PoE.
8IR Ctrl (IR input) – 3.5mm stereo jack. Connect to
third party control system if using IR as the chosen
method of controlling the Multicast system. When
using the included 3.5mm stereo to mono cable,
ensure the cable direction is correct.
9IR - adjust IR voltage level between 5V or 12V input
for IR Ctrl.
qPower LED indicator
wPower port – use 12V 1A DC adaptor (sold separately)
if not using a PoE network switch.
Rear Panel
Panel Descriptions - ACM200 & ACM210
5
11
3
10
RS-232 NORMAL RESET 5V 12V
IO1
IO2
IO3
IO4
V OUT
IO LEVELMCU
ACM210

05
contact support@blustream.co.uk / support@blustream.com.au / support@blustream-us.com
ACM - Multicast Advanced Control Module USER MANUAL
The ACM communication ports are located on both end panels and include the following connections:
Connections:
A. TCP/IP – for Multicast system control (RJ45 connector)
B. Infrared (IR) Input* - 3.5mm stereo jack - for Multicast I/O switching control only
C. RS-232 – for Multicast system control / RS-232 pass-through (DB9)
* Please note: the ACM200 can be used with both 5V and 12V IR line systems. Please ensure that the switch (adjacent
to the IR port) is correctly selected to the specification of the IR line input from the control system.
TCP/IP:
The Blustream ACM can be controlled via TCP/IP. For the full list of protocols please see the separate ‘API Commands’
document which can be downloaded from the Blustream website. A ‘straight-through’ RJ45 patch lead should be used
when connected to a network switch.
Control Port: 23
Default IP: 192.168.0.225
Default Username: admin
Default Password: 1 2 3 4
Please note: at the first log-in to the ACM, a new password will be required to be entered. It is not possible to reset this
without resetting the ACM unit. Please ensure the new password is noted down and kept for future reference.
RS-232 / Serial:
The ACM can be controlled via serial using the DB9 connector. Default settings below. For the full list of protocols
please see the separate ‘API Commands’ document which can be downloaded from the Blustream website.
Baud Rate: 57600
Data Bit: 8-bit
Parity: None
Stop Bit: 1-bit
Flow Control: None
The baud rate for the ACM can be adjusted using the web-GUI, or by issuing the following command via RS-232 or
Telnet: RSB x : Set RS-232 Baud Rate to Xbps
Where X= 0 : 115200
1 : 57600
2 : 38400
3 : 19200
4 : 9600
ACM Control Ports
AC
B
RS-232 NORMAL RESET 5V 12V
IO1
IO2
IO3
IO4
V OUT
IO LEVELMCU
ACM210
VIDEO LAN (PoE) CONTROL LAN IR CTRL
IR
5V 12V
LINKLINKPoE
12V 1A

ACM - Multicast Advanced Control Module USER MANUAL
06 www.blustream.co.uk / www.blustream.com.au / www.blustream-us.com
VIDEO LAN (PoE) CONTROL LAN IR CTRL
IR
5V 12V
LINKLINKPoE
12V 1A
The Multicast system can be controlled using local IR control from a third party control system. Source selection is
the only feature available when using local IR control - advanced features of the ACM such as video wall mode, audio
embedding etc. can only be achieved using RS-232 or TCP/IP control.
Blustream have created 16x input & 16x output IR commands allowing source selection of up to 16x Multicast
Transmitters on up to 16x Multicast Receivers. For systems larger than 16x source devices, RS-232 or TCP/IP control
will be required.
ACM Control Ports - IR Control
Link
RXTX CH Select
IR IR
Rx Tx Gnd
RS-232 CH
IP100UHD-RXMULTICAST UHD
1 2 3 4
41 42 43 44
45 46 47 48
49 50 51 52
53 54 55 56
57 58 59 60
61 62 63 64
65 66 67 68
69 70 71 72
73 74 75 76
77 78 79 80
5 6 7 8
9 10 11 12
13 14 15 16
17 18 19 20
21 22 23 24
25 26 27 28
29 30 31 32
33 34 35 36
37 38 39 40
MULTICAST
IR Receiver - IRR - stereo 3.5mm jack (optional)
Blustream 5V IR receiver to receive an IR signal and distribute
through Blustream products
Wiring pin - IR-CAB - stereo 3.5mm jack:
Signal
5V
Ground
The ACM is compatible with both 5V and 12V IR equipment. When the ACM is being used to receive an IR input into the
IR CTRL port, the adjacent switch must be toggled correctly to suit the IR voltage line of the chosen control system
before connection.
Please note: supplied Blustream IR cabling is all 5V
Third Party Control System
(source selection only)
3.5mm Stereo to Mono Cable - IR-CAB (included)
Blustream IR Control cable 3.5mm Mono to 3.5mm Stereo for
linking third party control solutions to Blustream products.
Compatible with 12V IR third party products.
Please note: Cable is directional as indicated
Wiring pin - IR-CAB - mono 3.5mm jack:
Signal
Ground

07
contact support@blustream.co.uk / support@blustream.com.au / support@blustream-us.com
ACM - Multicast Advanced Control Module USER MANUAL
ACM Network Connection
The ACM acts as a bridge between the control network and video network to ensure that the data travelling between
the two networks are not mixed. The ACM must be connected via CAT cable in accordance with typical networking
requirements.
Example Schematic
EX40B-Kit
RS-232
LAN Cable
IR Cable
Example Schematic
ACM200
IO Level
Reset
VOut
IO4
IO3
IO2
IO1
5VNormal
RS-232
MCU
12V
ACM200
Video LAN(PoE) Control LAN IR Ctrl
IR
5V 12V DC 12V
Power
Link Link
PoE
Yellow Green Yellow Green
Reserved for future update
Control Processor
Optional 12V PSU
where no PoE is available
Multicast UHD
Network Switch
Customer Home / Business
Network Switch
1G Managed Network Switch
1G Managed Network Switch

ACM - Multicast Advanced Control Module USER MANUAL
08 www.blustream.co.uk / www.blustream.com.au / www.blustream-us.com
Web-GUI Guide
The web-GUI of the ACM allows for full configuration of a new system, as well as ongoing maintenance and control of
an existing system through a web portal.
The ACM can (eventually) be accessed on any internet connected device including: tablets, smart phones and laptops
that are on the same 'Control' network. The ACM is shipped with a static IP address (as below), and is not set with
DHCP enabled.
Sign In / Log In
We would recommend that a computer / laptop is connected directly to the Control port of the ACM for the initial
configuraiton of a new system. As noted previously, the ACM is shipped with a static IP address, not HDCP. There are
instructions of how to amend the static IP address of a computer / laptop towards the rear of this manual.
To log in, open a web browser (i.e. Safari, Firefox, MS Edge etc.) and navigate to the default static IP address of the ACM
which is:
192.168.0.225
The sign in page is presented on connection to the ACM. The default admin password is: 1 2 3 4
The ACM requires a new password to be set for the Administrator on first log-in. It is not possible to reset this without
resetting the ACM unit. Please ensure the new password is noted down and kept for future reference. Once the new
password has been created, the ACM will require this once further to log-into the administration menu of the unit.

09
contact support@blustream.co.uk / support@blustream.com.au / support@blustream-us.com
ACM - Multicast Advanced Control Module USER MANUAL
On first log in of the ACM, a Set-up Wizard for configuring all components of the Multicast system will be presented.
This has been designed to speed up new system configuration as all default / new Multicast Transmitters & Receivers
can be connected to the network switch at the same time, whilst not resulting in an IP conflict during the system
configuration. This results in a system in which all components are automatically and sequentially assigned a name
and IP address ready for basic system use.
New Project Set-up Wizard
The ACM Set-up Wizard can be cancelled by clicking 'Close'. Please be aware that the system will not be configured
at this point, but can be continued by visiting the 'Project' menu. If a Project File is already available (i.e. replacing an
ACM on an existing site), this can be imported by using the saved .json file by clicking 'Import Project'.
Click 'Next' to continue set-up:
If at this point the chosen Network hardware is not configured for use with a Blustream Multicast system, click on the
hyperlink 'network switch setup guides' to navigate to a centralised webpage containing common Network Switch
Guides.
An example schematic diagram for the connections of the ACM can be accessed by clicking the hyperlink marked
'diagram'. This will ensure the ACM is connected correctly to the wider Multicast system before the Set-up Wizard
begins. Once the connections of the ACM are confirmed, click 'Next'.

ACM - Multicast Advanced Control Module USER MANUAL
10 www.blustream.co.uk / www.blustream.com.au / www.blustream-us.com
New Project Set-up Wizard - continued...
During normal use, the ACM will poll for status updates and screen-grabs of the media travelling through the system.
The polling of this information constantly has an aect with larger systems (75+ end points). The next stage of the
configuration is to pre-define the size of project. The options here are:
0-75 Products
75+ Products
This setting can be adjusted in the future should the system size increase.
Click on the relevant button to select the system size:
Altri manuali per Multicast ACM200
2
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Blu Stream Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards