BW Technologies MicroClip XT Manuale utente

1
Quick Reference Guide
1, 2, 3, and 4 Gas Detector

Limited Warranty and Limitation Liability
BW Technologies LP (BW) warrants the product to be free from defects in material and workmanship under normal use and service for a period of two years, beginning on the
date of shipment to the buyer. This warranty extends only to the sale of new and unused products to the original buyer. BW’s warranty obligation is limited, at BW’s option, to
refund of the purchase price, repair or replacement of a defective product that is returned to a BW authorized service center within the warranty period. In no event shall BW’s
liability hereunder exceed the purchase price actually paid by the buyer for the Product.
This warranty does not include:
a) fuses, disposable batteries or the routine replacement of parts due to the normal wear and tear of the product arising from use;
b) any product which in BW’s opinion, has been misused, altered, neglected or damaged, by accident or abnormal conditions of operation, handling or use;
c) any damage or defects attributable to repair of the product by any person other than an authorized dealer, or the installation of unapproved parts on the product; or
The obligations set forth in this warranty are conditional on:
a) proper storage, installation, calibration, use, maintenance and compliance with the product manual instructions and any other applicable recommendations of BW;
b) the buyer promptly notifying BW of any defect and, if required, promptly making the product available for correction. No goods shall be returned to BW until receipt by the
buyer of shipping instructions from BW; and
c) the right of BW to require that the buyer provide proof of purchase such as the original invoice, bill of sale or packing slip to establish that the product is within the
warranty period.
THE BUYER AGREES THAT THIS WARRANTY IS THE BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. BW SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR BASED ON CONTRACT,
TORT OR RELIANCE OR ANY OTHER THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and
exclusions of this warranty may not apply to every buyer. If any provision of this warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will
not affect the validity or enforceability of any other provision.
Contacting BW Technologies by Honeywell
Email us at: [email protected]
Visit BW Technologies by Honeywell’s website at: www.honeywellanalytics.com
USA: 1-888-749-8878 Canada: 1-800-663-4164
Europe: 00800-333-22244 Other countries: +1-403-248-9226
The license for manufacturing measuring
instrument of the People’s Republic of China.
CMC No Hu Zhi 00000324
CPA No
2015C206-31
Company Standard No Q31/0114000029C002-2015

GasAlertMicroClip
Introduction
1
GasAlertMicroClip
Introduction
The Quick Reference Guide provides basic information for the
GasAlertMicroClip XT, XL and X3. For complete operating
instructions, refer to the GasAlertMicroClip User Manual from
www.honeywellanalytics.com. The GasAlertMicroClip (“the
detector”) warns of hazardous gas at levels above user-defined
alarm setpoints. The detector is a personal safety device. It is
your responsibility to respond properly to the alarm.
Note
The detector is shipped with English as the default
displayed language. Additional languages provided are
Portuguese, Spanish, German, and French. The screens
for the additional languages are displayed on the detector
and in the corresponding operator’s manuals.
What’s In a Box
Detector
Calibration Cap
Battery Charging Adapter
Documentation Kit
Certificate (GasAlertMicroClip XT)
Zeroing the Sensors
To zero the sensors, refer to steps #1-3 in Calibration on page 7.
ec Warning
This instrument contains a lithium polymer battery.
Dispose of lithium cells immediately. Do not disassemble
and do not dispose of in fire. Do not mix with the solid
waste stream. Spent batteries should be disposed of by a
qualified recycler or hazardous materials handler.
ec Avertissement
Cet appareil contient une batterie au lithium polymère.
Mettez immédiatement au rebut les piles au lithium
usagées. Veillez à ne jamais les démonter ou les jeter au
feu. Ne les mélangez pas aux autres déchets solides. Les
piles usagées doivent être éliminées par un centre de
recyclage agréé ou par un centre de traitement de matières
dangereuses.

GasAlertMicroClip
Quick Reference Guide
2
XT, XL and X3 Safety Information - Read First
Use the detector only as specified in this manual and the
reference guide, otherwise the protection provided by the
detector may be impaired. Read the following cautions before
using the detector.
a Cautions
•Warning: Substitution of components may impair
Intrinsic Safety.
• Caution: For safety reasons, this equipment must be
operated and serviced by qualified personnel only.
Read and understand the user manual completely
before operating or servicing.
• Charge the detector before first time use. BW
recommends the detector be charged after every
workday.
• Before using the detector, refer to Sensor Poisons and
Contaminants.
• Calibrate the detector before first-time use and then on
a regular schedule, depending on use and sensor
exposure to poisons and contaminants. BW
recommends calibrating at least once every 180 days
(6 months).
• The combustible sensor is factory calibrated to 50%
LEL methane. If monitoring a different combustible gas
in the %LEL range, calibrate the sensor using the
appropriate gas.
• Only the combustible gas detection portion of this
instrument has been assessed for performance by
CSA International.
• Calibrate only in a safe area that is free of hazardous
gas and in an atmosphere of 20.9% oxygen.
• It is recommended that the combustible sensor be
checked with a known concentration of calibration gas
after any exposure to contaminants/poisons such as,
sulfur compounds, silicon vapors, halogenated
compounds, etc.
• BW recommends to bump test the sensors before each
day’s use to confirm their ability to respond to gas by
exposing the detector to a gas concentration that
exceeds the alarm setpoints. Manually verify that the
audible and visual alarms are activated. Calibrate if the
readings are not within the specified limits.
• Caution: High off-scale readings may indicate an
explosive concentration.
• Any rapid up scaling reading followed by a declining or
erratic reading may indicate a gas concentration
beyond the upper scale limit, which can be hazardous.
• Extended exposure of the GasAlertMicroClip to certain
concentrations of combustible gases and air may stress
a detector element that can seriously affect its

GasAlertMicroClip
XT, XL et X3 Informations de sécurité – À lire au préalable
3
performance. If an alarm occurs due to a high
concentration of combustible gases, calibrate the
detector. If necessary, replace the sensor.
• Protect the combustible sensor from exposure to lead
compounds, silicones, and chlorinated hydrocarbons.
• Sensor exposure to certain organic vapors (such as
leaded gasoline and halogenated hydrocarbons) may
temporarily inhibit sensor performance. After exposure,
a bump test or calibration is recommended.
• For use only in potentially explosive atmospheres
where oxygen concentrations do not exceed 20.9%
(v/v).
• Products may contain materials that are regulated for
transportation under domestic and international
dangerous goods regulations. Return product in
compliance with appropriate dangerous goods
regulations. Contact freight carrier for further
instructions.
XT, XL et X3 Informations de sécurité –
À lire au préalable
Respectez rigoureusement les instructions d'utilisation figurant
dans ce manuel ainsi que dans le guide technique sous peine
de compromettre la protection offerte par le détecteur. Lisez les
mises en garde suivantes avant d’utiliser le détecteur.
a Mises en garde
•Avertissement : Le remplacement d'un composant de
l'appareil peut compromettre la sécurité intrinsèque du
détecteur.Mise en garde : Pour des raisons de sécurité,
cet appareil doit être utilisé et entretenu par du
personnel qualifié uniquement.
Lisez attentivement le manuel avant d’utiliser l’appareil
ou d'en assurer l'entretien et assurez-vous d'en avoir
bien compris les instructions.
• Chargez le détecteur avant sa première utilisation. BW
recommande de recharger le détecteur après chaque
journée d’utilisation.
• Avant toute utilisation du détecteur, reportez-vous à la
section .
• Étalonnez le détecteur avant sa première utilisation,
puis de manière régulière, en fonction de l’utilisation et
de l’exposition du capteur aux poisons et autres
contaminants. BW recommande d'effectuer un
étalonnage au moins une fois tous les 180 jours
(6 mois).
• Le capteur de gaz combustibles est étalonné en usine
au méthane, à une concentration de 50 % de la LIE. Si le
contrôle porte sur un autre gaz combustible dans la
plage de % LIE, étalonnez le capteur en utilisant le gaz
approprié.

GasAlertMicroClip
Quick Reference Guide
4
• Sur cet appareil, seule la détection de gaz combustibles
a fait l’objet d’une évaluation des performances par
CSA International.
• Veillez à effectuer l'étalonnage dans une zone sûre,
exempte de gaz dangereux, et dans une atmosphère
contenant 20,9 % d'oxygène.
• Si le capteur de gaz combustibles a été exposé à des
contaminants/poisons (composés de soufre, vapeurs de
silicium, produits halogénés, etc.), il est conseillé de
vérifier son bon fonctionnement en le mettant en
présence d'une concentration connue d'un gaz.
• Avant chaque utilisation quotidienne, BW recommande
d’effectuer un test fonctionnel des capteurs afin de
vérifier qu’ils réagissent bien aux gaz présents, en
exposant le détecteur à une concentration de gaz
supérieure aux seuils d’alarme. Vérifiez manuellement
que les alarmes sonore et visuelle sont activées.
Étalonnez l’appareil si les relevés ne sont pas
conformes aux limites spécifiées.
• Mise en garde : Des relevés élevés hors échelle peuvent
indiquer la présence d’une concentration explosive.
• Toute mesure en rapide augmentation suivie d’une
diminution ou d’une mesure fantaisiste peut indiquer
une concentration de gaz au-delà de la limite d’échelle
supérieure, risquant donc d’être dangereuse.
• Une exposition prolongée du GasAlertMicroClip XT à
certaines concentrations de gaz combustibles et dans
certaines atmosphères peut nuire à l'élément de
détection et altérer gravement ses performances.
Étalonnez le détecteur après toute exposition à des
concentrations élevées de gaz combustibles ayant
déclenché son alarme. Si nécessaire, remplacez le
capteur.
• Protégez le capteur de gaz combustibles contre toute
exposition aux composés de plomb, aux silicones et
aux hydrocarbures chlorés.
• L'exposition du capteur à certaines vapeurs organiques
(comme l'essence au plomb ou les hydrocarbures
halogénés) peut altérer temporairement son bon
fonctionnement. Il est recommandé de procéder à un
test fonctionnel ou à un étalonnage après toute
exposition.
• Cet appareil est destiné uniquement à une utilisation
dans des atmosphères potentiellement explosives,
dans lesquelles la concentration d’oxygène ne dépasse
pas 20,9 % (v/v).
• Les produits peuvent contenir des matériaux qui sont
réglementés pour le transport en vertu des règlements
nationaux et internationaux de marchandises
dangereuses. Retourner le produit conformément à la
réglementation sur les marchandises dangereuses
appropriées. Contactez transporteur de fret pour plus
d'instructions

GasAlertMicroClip
Parts of the GasAlertMicroClip
5
Parts of the GasAlertMicroClip
8
6
9
4
5
3
7
10
11
2
2
1
2
Item Description
1 IntelliFlash
2 Visual alarm indicators (LEDs)
3 Alligator clip
4 Charging connector / IR interface
5 Pushbutton
6 Carbon monoxide (CO) sensor
7 Hydrogen sulfide (H2S) sensor
8 Oxygen (O2) sensor
9 Combustible (LEL) sensor
10 Audible alarm
11 Liquid crystal display (LCD)

GasAlertMicroClip
Quick Reference Guide
6
Display Elements
1
8
7
6
54
3
2
Item Description
1 Alarm condition
2 Automatically zero sensor
3 Numeric value
4 Stealth mode
5 Battery life indicator
6 Gas identifier bars
7 Gas cylinder
8 Automatically span sensor

GasAlertMicroClip
Pushbutton
7
Pushbutton
• To activate the detector, press C.
• To deactivate the detector, press and hold C until the OFF
countdown is complete and the LCD deactivates.
• To view the TWA, STEL, and MAX (maximum) readings, press
C twice. To clear the TWA, STEL, and MAX readings, press
C when the LCD displays RESET.
• To initiate calibration, deactivate the detector. Press and hold
C while the detector performs the OFF countdown. Continue
holding C while the LCD briefly deactivates and then begins
the CAL countdown. Release C when the CAL countdown is
complete.
• To activate the backlight while in normal operation, press C.
• To acknowledge latched alarms, press C.
•To acknowledge a low alarm and disable the audible alarm,
press C (if the Low Alarm Acknowledge option is enabled).
Sensor Poisons and Contaminants
Several cleaners, solvents, and lubricants can contaminate and
cause permanent damage to sensors. Before using cleaners,
solvents, and lubricants in close proximity to the detector
sensors, read the following caution and table.
a Caution
Use only the following BW Technologies by Honeywell
recommended products and procedures:
• Use water based cleaners.
• Use non-alcohol based cleaners.
• Clean the exterior with a soft, damp cloth.
• Do not use soaps, polishes, or solvents.
Below are common products to avoid using around sensors.
Cleaners and Lubricants
• Brake cleaners
• Lubricants
• Rust inhibitors
• Window and glass cleaners
• Dishsoaps
• Citrus based cleaners

GasAlertMicroClip
Quick Reference Guide
8
• Alcohol based cleaners
• Hand sanitizers
• Anionic detergents
• Methanol (fuels and antifreezes)
Silicones
• Silicone cleaners and protectants
• Silicone based adhesives, sealants, and gels
• Hand/body and medicinal creams containing silicone
• Tissues containing silicone
• Mold releasing agents
• Polishes
Aerosols
• Bug repellents and sprays
• Lubricants
• Rust inhibitors
• Window cleaners
Altri manuali per MicroClip XT
2
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali BW Technologies Strumento di misura

BW Technologies
BW Technologies Gas Alert Clip Manuale utente

BW Technologies
BW Technologies GasAlert MicroClip XT Manuale utente

BW Technologies
BW Technologies GasAlertQuattro 3 Manuale utente

BW Technologies
BW Technologies GasAlertMicro5 Manuale utente

BW Technologies
BW Technologies BW Clip Manuale utente