CDL 210100U Manuale utente

OWNER’S
MANUAL CDL ULTRASONIC
FLOWMETERS
Version 1.0
10/15/2020
© Tous droits réservés – CDL Maple Sugaring Equipment Inc.
Models : 210100U | 210150U | 210200U | 210300U

CDL Maple Sugaring Equipment Inc.
2
TABLE OF CONTENTS
INTRODUCTION .................................................................................................................. 3
PRODUCT FEATURES .......................................................................................................... 4
INSTALLATION DIAGRAM................................................................................................... 5
INSTALLATION DIAGRAM................................................................................................... 6
INSTALLATION DIAGRAM................................................................................................... 7
SUMMARY BY MODEL........................................................................................................ 8
DISPLAY OF CURRENT FLOW AND ACCUMULATED VOLUME........................................... 9
RESETTING VOLUMES TO ZERO ....................................................................................... 10
CDL MONITORING INTERFACE ......................................................................................... 12
MAINTENANCE ................................................................................................................. 14
WARRANTY....................................................................................................................... 15

CDL Maple Sugaring Equipment Inc.
3
INTRODUCTION
• Important: This type of flowmeter cannot be used on the outlets of vaccum extractors.
• Ideally, these flowmeters should be used at the outlet of a vacuumless delivery pump.
• The flowmeter works for positive and negative displacement. For example, if the pump
starts, it will add the amount of water to the positive flow. When the pump stops and
the hose drains in the opposite direction, the amount of water returning to the tank will
be subtracted from the total previously accumulated by the flowmeter.
• The flowmeter is sold as a pre-mounted kit and calibrated for a pipe that will meet the
minimum distances. However, you still have to install the device appropriately. (See the
Installation Diagram section).
• Please make sure to read these instructions carefully before installing in order to ensure
your flowmeter is as accurate as possible. In the Installation Diagram section, you will
find examples of proper and improper installation.
• The flowmeters come pre-programmed from the company. You do not need to adjust
the settings. By default, the display will be in gallons. However, you will be able to see it
in litres on your CDL monitoring interface if you wish. See the CDL Monitoring Interface
section.
• The flowmeter will automatically connect to your CDL monitoring system once you
connect it to a power source. See the CDL Monitoring Interface section for more details.
• For further information on flowmeter settings or functions, contact CDL Customer
Service at 1-800-361-5158

CDL Maple Sugaring Equipment Inc.
4
PRODUCT FEATURES
Power supply: 24V DC
Flowmeter material: PVC
Accuracy: ± 1%
Maximum pressure: 150 PSI
Maximum temperature: 60 degrees Celsius or 140 degrees Fahrenheit
Protection: IP68

CDL Maple Sugaring Equipment Inc.
5
INSTALLATION NOTES
Please read the note below before consulting the
Installation Diagram.
1. As a basic principle, the tube should always be full so that the
flowmeter can get a proper reading.
2. Reduce turbulence inside the tube as much as possible to
ensure accuracy.
3. The controller and Mesh communication module can be
screwed into the desired location.
INSTALLATION DIAGRAM
Input
Output
Direction of flow
Note: The *** ID *** is inner diameter

CDL Maple Sugaring Equipment Inc.
6
INSTALLATION DIAGRAM
Correct
if flow rate controlled
by a valve
Inc
orrect if flow rate controlled by
a valve

CDL Maple Sugaring Equipment Inc.
7
INSTALLATION DIAGRAM

CDL Maple Sugaring Equipment Inc.
8
SUMMARY BY MODEL
1 '' Model
210100U
10x ID = Straight line (no elbows) of 10’’ minimum before the flowmeter’s inlet
5x x ID = Straight line (no elbows) of 5’’ minimum before the flowmeter’s inlet
1 ½ '' Model
210150U
10x ID = Straight line (no elbows) of 15’’ minimum before the flowmeter’s inlet
5x x ID = Straight line (no elbows) of 7 ½’’ minimum before the flowmeter’s inlet
2 '' Model
210200U
10x ID = Straight line (no elbows) of 20’’ minimum before the flowmeter’s inlet
5x x ID = Straight line (no elbows) of 10’’ minimum before the flowmeter’s inlet
3 '' Model
210300U
10x ID = Straight line (no elbows) of 30’’ minimum before the flowmeter’s inlet
5x x ID = Straight line (no elbows) of 15’’ minimum before the flowmeter’s inlet

CDL Maple Sugaring Equipment Inc.
9
DISPLAY OF CURRENT FLOW AND ACCUMULATED
VOLUME
If the display does not show the current flow rate and accumulated volume, follow the
steps below.
Step 1: Press to see “Window No.”on the screen, as below.
Step 2: Press:
Step 3: Press :
Displays accumulated volume in
accumulated gallons
Displays of current flow rate
in gallons per minute (gpm)

CDL Maple Sugaring Equipment Inc.
10
RESETTING VOLUMES TO ZERO
Step 1: Press to get “Window No.”on the screen, as below.
Step 2: Enter the number 37 using the keypad by pressing followed by
Step 3: Press . The screen should display this:
Step 4: Press once to select YES. The screen should display this:
Step 5: Press . The screen should display this:
Questo manuale è adatto per i seguenti modelli