5. Parameters Setting Method
Example: Please short-cut terminal 15 & 17 and open terminal 15 & 16
Step 1. Press MODE button
PRGblink 01
0004
Step 2. Press ▲or ▼button to modify value
PRGblink 01
0005
Step 3. Press SET button to confirm the value modification finished.
000.0
100.0
Accomplishing setting, system will return to normal display operation after a
few seconds. If you need to modify other parameters, please repeat the
procedure above. Press MODE button on and on, the red LED will display
parameters 01~07 in a circle.
6.Function: Parameters Table
Parameter
No. Function Range Factory
Setting User
Setting
01 406s function selection 0-31 8
02 Response time 1-99 30
03 Time adjust for speed up
and down 1-99 30
04 Ratio “K” for main speed 100-9999 1000
05 Linear speed “K” 100-9999 1000
06 Upper limit of speed 0-9999 1000
07 *Additional
(Voltage per start) 0-255 30
*If the setting is 30, the result is 3 second.
Higher of the value of parameter 02 and 03 results slower response time.
Parameter 04, 05 and 06 have to modify depending on actual situation.