Contents
Common hardware components 3
Datasheets 22
Citrix ADC MPX hardware-soware compatibility matrix 22
Hardware platforms 25
Citrix ADC MPX 5500 25
Citrix ADC MPX 5550 and MPX 5650 27
Citrix ADC MPX 59xx 28
Citrix ADC MPX 7500 and MPX 9500 30
Citrix ADC MPX 8005, MPX 8015, MPX 8200, MPX 8400, MPX 8600, and MPX 8800 32
Citrix ADC MPX 89xx 34
Citrix ADC MPX 9700, MPX 10500, MPX 12500, and MPX 15500 37
Citrix ADC MPX 11500, MPX 13500, MPX 14500, MPX 16500, MPX 18500, and MPX 20500 40
Citrix ADC MPX 115xx 42
Citrix ADC MPX 14xxx 44
Citrix ADC MPX 14xxx-40C 46
Citrix ADC MPX 14xxx-40G 48
Citrix ADC MPX 14xxx-40S 50
Citrix ADC MPX 14xxx FIPS 52
Citrix ADC MPX 15000 54
Citrix ADC MPX 15000-50G 55
Citrix ADC MPX 17500, MPX 19500, and MPX 21500 58
Citrix ADC MPX 17550, MPX 19550, MPX 20550, and MPX 21550 60
Citrix ADC MPX 22xxx 61
© 1999-2019 Citrix Systems, Inc. All rights reserved. 2

Citrix ADC MPX
Citrix ADC MPX 241xx 64
Citrix ADC MPX 25xxxA 66
Citrix ADC MPX 251xxT 68
Citrix ADC MPX 25xxxTA 70
Citrix ADC MPX 25xxx-40G 72
Citrix ADC MPX 26xxx 74
Citrix ADC MPX 26xxx-50S 75
Citrix ADC MPX 26xxx-100G 77
Citrix ADC T1010 80
Citrix ADC T1100 81
Citrix ADC T1120 83
Citrix ADC T1200 84
Citrix ADC T1300 86
Citrix ADC T1310 87
Citrix Web App Firewall platforms 89
Field replaceable units 90
Safety, cautions, warnings, and other information 103
Taiwan BSMI RoHS statement 109
FCC compliance statement 110
Prepare for installation 111
Install the hardware 113
Initial configuration 122
Lights out management port of the Citrix ADC MPX appliance 135
Configure the network settings on the LOM port 136
© 1999-2019 Citrix Systems, Inc. All rights reserved. 3

Citrix ADC MPX
Install a certificate and key on the LOM GUI 141
Obtain the MAC address, serial number, and host properties of the appliance 147
Perform power control operations by using the LOM port 148
Restore the BMC configuration to factory defaults 150
Use the BIOS POST code to detect errors 151
Upgrade the LOM firmware on a Citrix ADC MPX appliance 151
Hardware health attributes 152
Wiping your data before sending the ADC appliance to Citrix 163
Migrate the configuration of an existing Citrix ADC appliance to another Citrix ADC appliance165
Troubleshooting 166
Hardware FAQs 168
© 1999-2019 Citrix Systems, Inc. All rights reserved. 4

Citrix ADC MPX
Common hardware components
November 19, 2019
Each platform has front panel and back panel hardware components. The front panel has an LCD
display and an RS232 serial console port. The number, type, and location of ports vary by hardware
platform for the following transceivers: copper Ethernet, copper and fiber 1G SFP, 10GSFP+, and 40G
QSFP+. The back panel provides access to the fan and the field replaceable units (power supplies, and
solid-state and hard-disk drives).
LCD display and LED status indicators
The LCD display on the front of every appliance displays messages about the current operating status
of the appliance. These messages communicate whether your appliance has started properly and
is operating normally. If the appliance is not operating normally, the LCD displays troubleshooting
messages.
The LCD displays live statistics, diagnostic information, and active alerts. The dimensions of the LCD
limit the display to two lines of 16 characters each. As the result, the displayed information flows
through a sequence of screens. Each screen shows information about a specific function.
The LCD has an LED backlight. Normally, the backlight glows steadily. When there is an active alert, it
blinks rapidly. If the alert information exceeds the LCD screen size, the backlight blinks at the begin-
ning of each display screen. Aer the appliance shuts down, the backlight remains on for one minute
and then automatically turns o.
On the appliance’s back panel, system status LEDs indicate the overall status of the appliance. The
following table describes the indicators of the system status LED.
Note: System status LEDs are available on only some Citrix ADC appliances.
System status LEDs
LED Color LED Indicates
OFF No power.
Green Appliance is receiving power.
Red Appliance has detected an error.
© 1999-2019 Citrix Systems, Inc. All rights reserved. 5

Citrix ADC MPX
The port LEDs show whether a link is established and traic is flowing through the port. The following
table describes the LED indicators for each port. There are two LED indicators for each port type.
Note: This section applies to all the appliances.
LED port-status indicators
Port Type LED Color LED Indicates
50 Gbps O A link has not been
established.
Blinking amber Indicates a problem with the
link
Solid green Indicates a valid link with no
active traic.
Blinking green Indicates a valid link with
active traic.
Port Type LED LED LED Color LED Indicates
10 Gbps Top Speed O No connection.
Solid blue or
solid green
Traic rate of 10
gigabits per
second.
Bottom Link/Activity O No link.
Solid green Link is
established but
no traic is
passing through
the port.
Blinking green Traic is passing
through the
port.
1G SFP (1 Gbps) Le Link/Activity O No link.
© 1999-2019 Citrix Systems, Inc. All rights reserved. 6

Citrix ADC MPX
Port Type LED LED LED Color LED Indicates
Solid green Link is
established but
no traic is
passing through
the port.
Blinking green Traic is passing
through the
port.
Right Speed O No connection.
Yellow Traic rate of 1
gigabit per
second.
Ethernet (RJ45) Le (Right on
MPX 5900
platform)
Speed O No connection,
or a traic rate of
10 megabits per
second (Mbps).
Green Traic rate of 100
Mbps.
Yellow Traic rate of 1
gigabit per
second.
Right (Le on
MPX 5900
platform)
Link/Activity O No link.
Blinking green Traic is passing
through the
port.
Management
(RJ45)
Le Speed O No connection,
or a traic rate of
10 megabits per
second (Mbps).
Green Traic rate of 100
Mbps.
© 1999-2019 Citrix Systems, Inc. All rights reserved. 7

Citrix ADC MPX
Port Type LED LED LED Color LED Indicates
Amber Traic rate of 1
gigabit per
second.
Right Link/Activity O No link.
Solid yellow Link is
established but
no traic is
passing through
the port.
On each power supply, a bicolor LED indicator shows the condition of the power supply.
3Y power supply
The 3Y power supply is used on the following platforms:
• 450 W AC/DC
–MPX 7500/9500
–MPX 8005/8010/8015
–MPX 8200/8400/8600/8800
–MPX 8900
–MPX 9700-10G/10500-10G/12500-10G/15500-10G
–MPX 9700/10500/12500/15500
• 1000 W AC/DC
–MPX 14xxx
–MPX 25xxx
–T1300
–MPX 15xxx
–MPX 26xxx
–MPX 26xxx-100G
• 1200 W AC/DC
–MPX 26xxx-50S
3Y power supply LED behavior
© 1999-2019 Citrix Systems, Inc. All rights reserved. 8

Citrix ADC MPX
Power Supply 450 W AC 450 W DC 1000 W AC 1000 W DC 1200 W AC
LED behavior
when
YM-2451CAR YM-2451DBR YM-
2102NA01R
YM-
2102JA01R
YM-
2122CA01R
No Power to
any power
supply
O O O O O
No power to
this power
supply
Flashing RED Flashing RED Flashing RED Flashing RED Flashing RED
Power supply
is in standby
mode
Flashing
GREEN
Flashing
BLUE
Flashing
GREEN
Flashing
GREEN
Flashing
GREEN
Power supply
is functional
GREEN BLUE GREEN GREEN GREEN
Power supply
failure
RED RED RED RED RED
Warning
(OVP/U-
VP/OCP/OTP/-
Fan)
- - - Flashing
RED/GREEN
-
Note
The following legacy platforms use the 300W 3Y power supply: 5850/5750/5650/5550/5500/5600.
Acbel power supply
The Acbel power supply is used on the following platforms:
• 450 W AC
–MPX 59xx
–MPX 89xx
• 450 W DC
–MPX 59xx
–MPX 89xx
Acbel 450 W power supply LED behavior
© 1999-2019 Citrix Systems, Inc. All rights reserved. 9

Citrix ADC MPX
Power Supply 450 W AC 450 W DC
LED behavior when R1BA2451B-GE9A R1B02451A
No Power to any power
supply
O O
No power to this power
supply
Flashing RED Flashing RED
Power supply is in standby
mode
Flashing GREEN Flashing BLUE
Power supply is functional GREEN BLUE
Power supply failure RED RED
Warning
(OVP/UVP/OCP/OTP/Fan)
- -
Note
AC power supplies use green LEDs and DC power supplies use blue LEDs.
Zippy power supply
The Zippy power supply is used on the following platforms:
• 960 W AC
–MPX 11515/11520/11530/11540/11542
–MPX 11500/13500/14500/16500/18500/20500
• 960 W DC
–MPX 11515/11520/11530/11540/11542
–MPX 11500/13500/14500/16500/18500/20500
Zippy 960 W power supply LED behavior
Power Supply 960 W AC 960 W DC
LED behavior when G1W2-5960V3V Rev.5 DG1W-3960 V
No Power to any power
supply
O O
No power to this power
supply
Continuous beep sound Continuous beep sound
© 1999-2019 Citrix Systems, Inc. All rights reserved. 10
Questo manuale è adatto per i seguenti modelli
53
Indice
Altri manuali Citrix Server