Step 5:Connect Pull Strings
Tie Connector Pull String to Duct Pull String
(Figure 14).
Figure14 Figure15
Step6:Unlock Deploy Reel
Pull out gently on Deploy Reel to unlock it from
the backpost (Figure 15).
Step7:Insert Connector
Insert Connector fully into duct before
pulling ber through. (Figure 16).
Figure16
Step8:PullFiberthroughDuct
Use the Duct Pull String to pull the
required length of ber through the
duct to the network access point.
Step 9:Assemble Connector End
Once pulled throught the duct,
assemble the FieldShield Connecter
following instructions provided with
the FieldShield Reel. (Figure 17).
Figure17
Watch the Installation Video
FieldShield SC Connector
www.clfd.net/media/deployreel.php
DO NOT use any type of
tape when tying the pull
string to the microduct pull
string. This will cause friction
and will result in blockage of
the microduct.
IMPORTANT