Clearfield FieldSmart FEC Manuale utente

FieldSmart®Fiber Entrance Cabinet (FEC)
Installation Manual ______________________________________________________
Manual 019612 REV B - Aug 2018

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
2
FieldSmart®Fiber Entrance Cabinet (FEC)
Installation Manual _________________________________________________________
Manual 019612 REV B - Aug 2018
Table of Contents
Application 3
Description 3
Technical Specications 3
FEC Overview 4
Cable Routing 5
Splicing 7
Grounding 10
Standard Warranty 11
Proprietary Notice 12
Technical Support 12

3
FieldSmart®Fiber Entrance Cabinet (FEC)
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 019612 REV B - Aug 2018
Application
Description
Technical Specications
FieldSmart FxDS Fiber Entrance Cabinet
Dimensions 17.5” H x 34.5” W x 8.25” D
Ratings Compliant to Telcordia GR-449
Cable Types Indoor Riser, Indoor Plenum, Indoor/Outdoor, Outdoor (Riser/Non-Rated), Outdoor Armored
(Riser/Non-Rated), FieldShield®
Splice Capacity 288 heat shrink fusion (HSF) loose tube or 864 mass fusion (MF) ribbon splices
Storage Capacity One meter of 900 μm ber and ve meters of exposed buffer tube
Material 16 gauge cold rolled steel with almond powder coating
The FieldSmart Fiber Entrance Cabinet (FEC) provides
off-frame splicing for the central ofce, headend or remote
hut. Fiber Entrance Cabinets are typically placed in the ber
entrance room and used to transition OSP ber sheaths to
IFC cabling
The FieldSmart FEC is built on a modular platform, scaling
288 heat shrink fusion (HSF) or 864 mass fusion (ribbon)
ber splices at a time. Multiple entry/exit points allow for
multiple distribution and OSP ber sheaths to enter into the FEC from top, bottom, or sidewalls and transition from conduit,
overhead ber tray, or raised ooring. A removable splice block, holding twelve 24-ber splice trays, gives the user the
ability to prep away from the cabinet. Intuitive buffer tube and sub-unit slack routing prevents cable tie-in with a clockwise
routing scheme to allow quick and easy re-entry after initial deployment or to add additional capacity. If vertical real estate is
available, the FEC can be ganged together, in modular fashion, allowing scalability up to 864-ber splices and beyond.
Each cable entrance plate will support cable diameters up to one inch. Lockable cupboard style doors allow for easy access
with minimal swing clearance needed for tight aisle clearances.

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
4
FieldSmart®Fiber Entrance Cabinet (FEC)
Installation Manual _________________________________________________________
Manual 019612 REV B - Aug 2018
The FieldSmart FEC is built on a modular platform scaling 288 ber splices at a time. Lockable cupboard style doors allow
for easy access with minimal swing clearance required for tight aisle clearances. The ber entrance cabinet comes with a
clamp kit.
Note: The FEC does NOT come with hardware to mount to the wall. Depending on the type or style of the wall the end user
should obtain the appropriate hardware from their local hardware store. There are four (4) mounting holes. The mounting
holes are .350” in diameter. The FEC Cabinet is 17.5” high x 34.5” wide and 8.25” deep.
FEC Overview
The parts below are shipped along with the FEC. The parts include the clamp kit and the plates to cover the numerous
cable entry/exit points. Splice trays sold separately.
Item Number Item Description Quantity
001527 SCREW, ROUND HEAD, PHILLIPS, 1/4-20 X 1 1/2” 8
002127 PLUG, BUTTON, BLACK POLYETHYLENE, FITS 1-5/16in HOLE X .01in-.10in THICK PANEL 14
003042 TAPE, GROMMETING, 1”, STRIPPING=1/8” X 1”, FEET 5
003083 STRAP, VELCRO, BLACK, 1/2” WIDE, FEET 2
003711 SADDLE, CLAMPING, 1/2” DIAMETER, GREEN POLYPROPYLENE, GRP3 4
003716 SADDLE, CLAMPING, 1” DIAMETER, GREEN POLYPROPYLENE, GRP3 4
009217 SCREW, PAN HEAD, PHILLIPS, 10-32 X 1/4”, 18-8 SST 32
009902 BRACKET, FEC ENCLOSURE 4
009909 PLATE, COVER, FEC, ENCLOSURE 15
An optional locking kit is available (P/N 010503) and is installed by two screws each at the top and bottom of the FEC. Lock
is not provided. Locking tab should be positioned to the right when installed.
17.5”
34.5”
34.5”
8.25”

5
FieldSmart®Fiber Entrance Cabinet (FEC)
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 019612 REV B - Aug 2018
Once the FEC is mounted to the wall, you are now ready to route ber into the cabinet.
Multiple entry/exit points allow for multiple distribution and OSP ber sheaths to enter the FEC from the top, bottom, or
sidewalls, transitioning from conduit, overhead ber tray or raised ooring. Cable entry/exit points are located around the
perimeter of the cabinet. See pictures below.
Note: Each cable entrance plate will support cable diameters up to 1 inch.
The cabinet comes with 4 sheet metal brackets for cable mounting and 16 blank plastic plates. The cables can be installed
with either the clamps on the outside of the cabinet or with the clamps on the inside of the cabinet for extra security. Plugs
are also included in the kit to ll the unused holes.
Choose the appropriate sized cable clamp for the cable entering the FEC. Always use a clamp large enough to close
around the cable, and utililze grommet tape to make up for the size difference by laying a small strip of grommet tape inside
the cable clamp shell. DO NOT use a clamp that “pinches” the cable.
Note: Grommet tape included in the kit may be used to build up the cable size to get a better grip with the provided clamps.
A removable splice block, holding twelve 24-ber splice trays, allows the user to prep away from the cabinet.
Note: Splice trays are sold separately (P/N 019339).
Cable Routing

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
6
FieldSmart®Fiber Entrance Cabinet (FEC)
Installation Manual _________________________________________________________
Manual 019612 REV B - Aug 2018
Intuitive buffer tube and subunit slack routing prevents cable tie-in’s, utilizing a clockwise routing scheme to allow quick and
easy re-entry after initial deployment or to add additional capacity.
If the cables are to be carried from one cabinet into the
next, then the blank plates and bracket plates will not
need to be used between the two cabinets. There is a
removable bracket on the top and bottom entrances
that will allow you to lay cables in without having to cut
them.
After choosing the entrance that will be used for your cables you will need to plan your cable route within the cabinet. All
cables should eventually route in a clockwise direction. Depending on where you enter the box you may have to use the
redirect spool in order to achieve a clockwise rotation.
No Redirect Used Redirect Used

7
FieldSmart®Fiber Entrance Cabinet (FEC)
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 019612 REV B - Aug 2018
After all cables are routed in the correct direction and there is an adequate
amount of slack in the cabinet, the cable tie down locations can be marked with a
permanent marker.
Splice trays (P/N 019339) will be shipped with 2 standard splice chips and 2
ribbon splice chips, allowing for a total of 24 loose tube splices or 6 ribbon mass
fusion splices (72 bers). Splice chips will need to be bent into place in the empty
slots in the center of the splice tray.
Note: Each standard splice chip features 6x2 splice sleeve slots, allowing for
12 splice sleeves to be stacked 2 high in the 6 slots. Each ribbon splice chip
features 3 ribbons splice sleeve slots, as well as one 2 high loose tube splice
sleeve slot for use in special applications or repairs.
Splicing
Splice Chip Ribbon Splice Chip Bending the Splice Chip
Splice Tray Loaded with
2 Splice Chips
Splice Tray Loaded with
2 Ribbon Splice Chips

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
8
FieldSmart®Fiber Entrance Cabinet (FEC)
Installation Manual _________________________________________________________
Manual 019612 REV B - Aug 2018
An example of a splice tray utilizing the splice
chips to secure 24 loose tube splice sleeves is
shown here.
Wrap a layer of grommet tape around the buffer
tubes and secure into place in the splice tray
using the tie-down holes and cable ties.
Provided with the splice tray are 3 ribbon tie-downs which utilize a split grommet and retention cover which will allow the
ribbon to be secured into the tray even in mid-span/ring cut applications.
Slip the split rubber grommet onto the ribbon, followed by the plastic retention cover over the opposite side.
Note: Extra ribbon tie-downs are available in a kit, which can be ordered separately (P/N 019501).
After protecting the ribbon ber with the ribbon
tie-down, secure it into the tray.
The splice tray features tie-down holes on each
side of the tray, which will allow for 5 ribbon tie-
downs per side, as well as one ribbon tie down on
each side in the additional holding location.
Additional Holding
Location
Standard
Tie-Down

9
FieldSmart®Fiber Entrance Cabinet (FEC)
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 019612 REV B - Aug 2018
The entire block of splice trays can be removed
for splicing by loosening the thumb screw in the
top left corner and lifting the block of splice trays.
After splicing, the splice trays can be secured into
place using the included velcro strap.
Thumb Screw Velcro
An example of a spliced up FEC, transitioning
from outside to inside plant cable, is shown here.

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
10
FieldSmart®Fiber Entrance Cabinet (FEC)
Installation Manual _________________________________________________________
Manual 019612 REV B - Aug 2018
FECs can be ganged together, in modular fashion, allowing scalability up to 864 ber splices and beyond if vertical real
estate is available. Below is an example of multiple FEC’s ganged together.
Grounding
FEC Cabinets are easily grounded using the integrated ground bar. Ground per your local rules and practices.
Indice
Altri manuali Clearfield Decoder via cavo
Manuali Decoder via cavo popolari di altre marche

StarTech.com
StarTech.com BOX4CABLE Manuale utente

Commercial Electric
Commercial Electric 5053-WH Manuale utente

Motorola
Motorola DCT6412 DUAL-TUNER DVR AND HD SET-TOP - MICROSOFT... Istruzioni per il montaggio

Renkforce
Renkforce 1395556 Manuale utente

Huawei
Huawei FAT9102SD-32G Manuale utente

VISSEM Electronics
VISSEM Electronics Opticube VSOF-OTB-E Manuale utente