CommScope SYSTIMAX 360 PATCHMAX Manuale utente

860584432
Issue 1, February 2015
www.commscope.com
SYSTIMAX 360™PATCHMAX®Modular Panel
Instructions
© 2015 CommScope, Inc.
All rights reserved
This product is covered by one or more U.S.
patents or their foreign equivalents. For patents, see
www.commscope.com/ProductPatent/ProductPatent.aspx
Page 1 of 12
For RoHS Inquiries:
CommScope Inc.
Corke Abbey, Bray
Co. Dublin, Ireland
Attn: Legal Department
General
The SYSTIMAX 360™PATCHMAXmodular panel can be used for both EIA-T568A or EIA-T568B wiring
applications and is an approved component for use in SYSTIMAXGigaSPEED®, and GigaSPEED X1OD
systems. The panel mounts in a standard 19-inch equipment rack and includes integrated front cord
management, removable rear cable management, and termination manager kit.
Ordering information is listed below.
Material ID
Part No.
Description
760102244
360-PM-GS3-2U
360 PATCHMAX 2U 24-port panel with GS3-DM 6-pack modules
760102251
360-PM-GS6-2U-24
360 PATCHMAX 2U 24-port panel with GS6-DM 6-pack modules
760108993
360-PM-KIT-2U-24
360 PATCHMAX 2U 24-port panel without modules
760117366
360-PM-GS3-2U-48P
360 PATCHMAX 2U 48-port panel with GS3-DM 12-pack modules
760128207
360-PM-GS6-2U-48
360 PATCHMAX 2U 48-port panel with GS6-DM 12-pack modules
760117408
360-PM-KIT-2U-48
360 PATCHMAX 2U 48-port panel without modules
SYSTIMAX 360™PATCHMAXModular Panel, 24-Port and 48-Port
How to Contact Us
To find out more about CommScope® products, visit us on the web at www.commscope.com/
For technical assistance:
- Within the United States, contact your local account representative or technical support at
1-800-344-0223. Outside the United States, contact your local account representative or
PartnerPRO™Network Partner.
- Within the United States, report any missing/damaged parts or any other issues to
CommScope Customer Claims at 1-866-539-2795 or email to [email protected].
Outside the United States, contact your local account representative or PartnerPRO Network
Partner.

860584432
Instruction Sheet
www.commscope.com
Page 2 of 12
Specifications
Wire Termination
Wire Size:
22-24 AWG (0.64 - 0.51 mm) Solid Copper
22-24 AWG (0.64 - 0.51 mm) Seven Stranded Copper
Insulation Size:
0.042 inch maximum DOD
Insulation Types:
Polyethylene, Polypropylene and FEP
IDC Reterminations:
20 minimum
Modular Jack Mating Cycles:
750 minimum
Environmental Data
Temperature Range:
-40°F (-40°C) to 158°F (70°C) (Storage)
14°F (-10°C) to 140°F (60°C) (Operational)
Humidity:
95% Noncondensing
Tools Required
Phillips head screwdriver
Cable jacket scoring tool
D-914 punch tool with M110 blade
Parts List
Verify parts against parts list below:
Quantity
Description
24-Port
48-Port
1
1
Panel supplied with either GS3-DM or GS6-DM distribution modules
1
1
Rear cable manager
4
8
Rear labels
4
4
Hook-and-loop straps
4
4
Mounting screws, 12-24 x 1/2”
1
1
Front cord management
1
1
Front bezel
1 kit
2 kits
Termination managers
1
2
Front label card (4 labels per card)
1
2
Label cover card (4 label covers per card)
1
1
Instruction sheet

www.commscope.com
860584432
Instruction Sheet
Page 3 of 12
Separately Orderable Items
Material ID
Description
760102269
360 PATCHMAX GS3-DM 6-pack distribution module
760102277
360 PATCHMAX GS6-DM 6-pack distribution module
760117382
360 PATCHMAX GS3-DM 12-pack distribution module
760128215
360 PATCHMAX GS6-DM 12-pack distribution module
760199760
Spare termination manager kit
WARNING –Important Safety Instructions
When using this product, the following basic safety precautions should be followed to reduce the risk of fire,
electric shock, and injury to persons:
1. Never install communications wiring in wet locations unless it is designed for wet locations.
2. Never install this product during a lightning storm. There is a remote risk of electric shock.
3. Never touch uninsulated communication wiring or terminals unless the communication circuit has been
disconnected at the network interface.
CAUTION: All wiring that connects to this equipment must meet applicable local and national building codes
and network wiring standards for communication cable.
Step 1 –Mount Panel to Rack
Single Panel Mounting Multiple Panel Mounting
1. Mount panel(s) to rack or cabinet using the four mounting screws provided.

860584432
Instruction Sheet
www.commscope.com
Page 4 of 12
Step 2 –Module Termination
T568 Wiring Diagram Termination Manager
Note: The module comes with a T568B wiring designation label installed. If T568A wiring is desired, first
remove the "B" type label and then place the "A" type label. Do not place the "A" type label on top of the
"B" type label.
1. Prepare cable for IDC termination. Terminate conductors on the IDC terminals per the wiring diagram shown
above and utilizing the termination manager.
2. See pages 11 and 12 for correct procedure on using the termination managers.
Preparation of X10D 91B Series Cable, 95B Series Cordage, or Xpress 88 Series
Cable for Termination
Preparation of the SYSTIMAX GigaSPEED X10D 91B series cable, 95B series cordage, or Xpress®88
series cable is shown above. For complete instructions on preparing the GigaSPEED X10D 91B series cable,
95B series cordage, or Xpress®88 series cable for termination, see instruction sheet 860469402.
8 7 6 5
2 1 4 3
4 4
3
2
1
2
3
1
B A
1 2 3 4 5 6 7 8 BR BR
GR
GR
OR
OR
BL BL
W
WW
W
T568 Wiring Pairs
IDC Connector
Modular Jack
Front of Panel Back of Panel
Pull flute and tapes
off to one or more sides
Unwind separator tape
Pull off to the side so that it can
be trimmed close to the jacket
Locktab
(2 places)
Entry
holes
Fold slots
(4 places)
Entryholes

www.commscope.com
860584432
Instruction Sheet
Page 5 of 12
Front Termination Procedure

860584432
Instruction Sheet
www.commscope.com
Page 6 of 12
1. Preinstall rear cable manager as outlined in Step 3 and loosely secure the tie wraps so that cables can be
pulled out and pushed in during front termination.
2. Depress four tabs on a 6-pack module (two tabs on a 12-pack module) and remove module from panel
opening and rotate 180º so that rear of module is facing forward. Temporarily snap module backwards into
an adjacent empty panel opening for terminating as shown on previous figures.
Note: It is necessary to temporarily remove modules from opposite panel opening of module being
terminated to facilitate the front cabling procedure. If adjacent module is already terminated, pull module out
and push cables to one side to allow space to temporarily install module being terminated into opening.
3. Pull an adequate length of cables through panel opening for the terminated module and mark the jacket ring
points. Verify that the cables can be pushed back into final position without snagging.
4. Prepare cables and punch down to module using punch-down tool with M110 blade on HI setting and
termination managers per the instructions on page 4.
Note: Hold module with one hand to secure it from sliding during punch down.
5. After all cables are terminated, remove module and rotate 180º so that front of module is again facing
forward. Position module back into panel opening that cables were pulled through and snap into place.
6. After modules are terminated, check to verify proper cable positioning. If access to rear is available, proceed
to Step 3.
Rear Termination Procedure
Note: Do not remove module from panel opening.
1. Establish proper lengths of cables to the modules so they can be positioned in the rear cable troughs after
installation in Step 3 and mark the jacket ring points.
2. Prepare cables and punch down to module using the punch-down tool with M110 blade on HI setting and
the termination managers per the instructions on page 4.
3. After the modules are terminated, proceed to Step 3.

www.commscope.com
860584432
Instruction Sheet
Page 7 of 12
Step 3 –Assemble and Install Rear Cable Manager
1. Attach the four cable troughs onto bar as shown and insert four hook-and-loop straps into slots in cable
troughs.
2. Attach cable bar to rear of panel.
3. Lay cables evenly in cable troughs and secure using hook-and-loop straps as shown. For front termination
leave straps loose to allow for access of modules.
4. The following figure illustrates a typical completed installation.

860584432
Instruction Sheet
www.commscope.com
Page 8 of 12
Step 4 –Install Front Cord Management, Front Bezel, Labels and Label Covers
1. Position front cord management as shown and slide onto mounting arms until it is seated.
2. Position front bezel at an angle as shown and insert two bottom retention tabs into slots in cord
management.
3. Pivot top of bezel towards panel and insert three tabs on top of bezel into slots in panel until an audible click
is heard.

www.commscope.com
860584432
Instruction Sheet
Page 9 of 12
4. Print the port designations on the white label cards provided. Slide labels and label covers into the label
holders from either end. Each label holder will accommodate labels up to .265 inches (6.7mm) high x 3.50
inches (89mm) wide.
5. Blank, voice, and data icons can be ordered separately in a wide variety of colors and placed into the
pockets in the lower portion of the label holders.
Note: Product code M61K-XX (blank, voice, and data icons) to be ordered separately.
XX denotes the color abbreviation.
6. To print a designation label, go to http://www.commscope.com/Resources/Labeling-Templates and scroll
down to 360 Panels and Shelves. Select the proper label template:
360 Evolve-360 PATCHMAX UNP Label Sheet A4 (760186502)
360 Evolve 360 PATCHMAX UNP Label Sheet US LTR (760183244)
Note: Labeling website has two options for printing labels: letter size and A4 size.

860584432
Instruction Sheet
www.commscope.com
Page 10 of 12
Additional Front Termination Access Instructions
1. Remove two terminated or un-terminated modules (ports 1-6 and ports 7-12) from panel opening to free up
space for new termination sequence. Leave modules out of panel.
2. Remove module to be terminated (ports 13-18) from panel, rotate 180° and temporarily reinstall in adjacent
panel opening.
3. Pull termination manager off by squeezing lock tabs and re-terminate with a replacement termination
manager as previously described in Step 2.
4. Remove newly terminated module, rotate 180° so that front of module again faces forward and reinstall in
proper panel opening.
5. Replace modules removed for this sequence back into place in panel.
Indice