Crestron GLA-LDL-PC-0-10-WL Manuale utente

GLA-LDL-PC-0-10-WL
Dual-Loop Photosensor
Product Manual
Crestron Electronics, Inc.

Original Instructions
The U.S. English version of this document is the original instructions.
All other languages are a translation of the original instructions.
Regulatory Model:
Crestron product development software is licensed to Crestron dealers and Crestron Service Providers (CSPs) under a
limited nonexclusive, nontransferable Software Development Tools License Agreement. Crestron product operating
system software is licensed to Crestron dealers, CSPs, and end-users under a separate End-User License Agreement.
Both of these Agreements can be found on the Crestron website at www.crestron.com/legal/software_license_
agreement.
The product warranty can be found at www.crestron.com/warranty.
The specific patents that cover Crestron products are listed at www.crestron.com/legal/patents.
Certain Crestron products contain open source software. For specific information, visit www.crestron.com/opensource.
Crestron, the Crestron logo, Cresnet, and Zūm are either trademarks or registered trademarks of Crestron Electronics,
Inc. in the United States and/or other countries. UL is either a trademark or registered trademark of Underwriters
Laboratories, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade
names may be used in this document to refer to either the entities claiming the marks and names or their products.
Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in
typography or photography.
©2022 Crestron Electronics, Inc.

Contents
Overview 5
Physical Description 6
Coverage 7
Light Level Settings 7
Specifications 8
Dimension Drawing 10
Installation 11
Determine the Mounting Location 11
Window Application 11
Skylight Application 12
Desk Level Application 12
Mount the Sensor 13
Flush Mount with Nipple 14
Surface Mount with Screws and Concealed Wires 15
Surface Mount with Screws and Surfaced Wires 16
Wire the Sensor 17
Resources 18
Crestron Support and Training 18
Product Certificates 18
Product Manual — Doc. 9267A Contents • iii

iv • Contents Product Manual — Doc. 9267A

Product Manual — Doc. 9267A GLA-LDL-PC-0-10-WL • 5
Overview
The GLA-LDL-PC-0-10-WL is a dual-loop photosensor that continually measures ambient light
in order to achieve the optimal balance of natural and artificial lighting in daylight harvesting
applications. By harnessing natural daylight from windows and skylights, electrical lighting can
be dimmed, reducing energy usage while maintaining a consistent light level for a more efficient
and comfortable work or living space. With an IP54 rating, the GLA-LDL-PC-0-10-WL is suitable
for indoor, outdoor and wet location applications.
In closed-loop type daylight harvesting applications, the GLA-LDL-PC-0-10-WL is installed on
the ceiling directly above the primary work area. It measures all light within a 60° cone, which
consists predominately of reflected light, acquiring the most natural approximation of perceived
changes in ambient light levels.
In open-loop type daylight harvesting applications, the GLA-LDL-PC-0-10-WL is installed on the
ceiling near a window or in the light well of a skylight, directed toward the incoming daylight and
away from any electrical lighting fixtures. The system estimates the total amount of ambient
lighting in the room according to the light level measured by the photocell.
The GLA-LDL-PC-0-10-WL includes hardware to facilitate flush or surface mounting to a
drywall or drop-tile surface. Its simple 3-wire interface allows for direct connection to a
Crestron® control system via a single Versiport I/O or analog input port, with 24 V power taken
from the Cresnet® network control bus.
NOTE: Cresnet communications requires a GLS-SIM or ZUMMESH-JBOX-SIM (both are sold
separately). Power may be taken from Cresnet bus regardless of interface method.
Connects to a GLS-SIM, ZUMMESH-JBOX-SIM, Versiport I/O, or Analog Input control port
on any Crestron control system.
Using an optional sensor integration module (GLS-SIM or ZUMMESH-JBOX-SIM for a Zūm® J-
Box, both sold separately), the GLA-LDL-PC-0-10-WL becomes a full-featured Cresnet device,
streamlining the total lighting system. Cresnet provides a simple solution for configuring and
wiring sensors as part of any complete Crestron system. The Cresnet bus is the communications
backbone for many Crestron keypads, lighting controllers, shade motors, sensors, and other
devices.

6 • GLA-LDL-PC-0-10-WL Product Manual — Doc. 9267A
Physical Description
This section provides a breakdown of the physical components of the device.
① Photo Cell 0-10V
② Wires including WAGOconnectors
③ Back plate
④ Screws
⑤ Dowels
⑥ Washer
⑦ Lock nut
⑧ 1/2 in. threaded chase nipple

Product Manual — Doc. 9267A GLA-LDL-PC-0-10-WL • 7
Coverage
Depending on the application, the sensor has two possible fields of view. This is set by installing
jumpers as described in the Light Level Settings section below.
① Sensor field of view when using Open Loop Control (OL)
② Sensor field of view when using Closed Loop Control (CL)
Light Level Settings
Jumpers are used to set the light level range and sensor field of view.
The following options can be set by installing jumpers in the specified locations:
A. OL: 3-300 fc (factory default)
B. OL: 30-3000 fc
C. OL: 60-6000 fc
D. CL: 3-300 fc

Product Manual — Doc. 9267A GLA-LDL-PC-0-10-WL • 8
Specifications
Sensing
Field of view 60° cone
Light sensitivity CL: 3-300 fc
OL: 3-6000 fc
Center axis CL: 90°
OL: 45°
Controls and Connections
Light sensitivity settings OL: 3-300 fc (factory setting);
OL: 30-3000 fc;
OL: 60-6000 fc;
CL: 3-300 fc
NOTE: Field of view and light sensitivity are set by installing jumpers on the
device.
Flying leads (1) Red Input flying lead; 24VDC power input;
(1) Black Ground flying lead;
(1) Orange Output flying lead;
Recommend wire size:18AWG;
Light level control signal output;
Provides 0-10V analog control signal proportionate to the ambient light level;
Connects to a Crestron® sensor integration module (GLS-SIM or
ZUMMESH-JBOX-SIM, sold separately) or to a Versiport I/O or Analog Input
control port on any Crestron control system
Power Requirements
Current Consumption 2mA class 2 at 24VDC
Cresnet Power Usage ~.1 W;
Cresnet communications requires a GLS-SIM or ZUMMESH-JBOX-SIM (both
are sold separately). Power may be taken from Cresnet bus regardless of
interface method. Connects to a GLS-SIM, ZUMMESH-JBOX-SIM, Versiport
I/O, or Analog Input control port on any Crestron control system.
Environmental
Temperature -40° to 158°F (-40° to 70°C)
For indoor or outdoor use
IPRating IP54

9 • GLA-LDL-PC-0-10-WL Product Manual — Doc. 9267A
Housing
Construction High-impact injection-molded plastic
Mounting Surface or flush ceiling mount directly to drywall or drop-tile
Dimensions
Height 1.06 in. (27 mm)
Diameter 2.01 in. (51 mm)
Weight
.011 lb (.05 kg)
Compliance
UL® Listed

Product Manual — Doc. 9267A GLA-LDL-PC-0-10-WL • 10
Dimension Drawing
Indice