CYP CPHD-V4 Manuale utente

CPHD-V4
4K UHD+ HDMI Signal Generator & Analyzer
Operation Manual
Operation Manual


DISCLAIMERS
The information in this manual has been carefully checked and
is believed to be accurate. Cypress Technology assumes no
responsibility for any infringements of patents or other rights of third
parties which may result from its use.
Cypress Technology assumes no responsibility for any inaccuracies
that may be contained in this document. Cypress also makes no
commitment to update or to keep current the information contained
in this document.
Cypress Technology reserves the right to make improvements to this
document and/or product at any time and without notice.
COPYRIGHT NOTICE
No part of this document may be reproduced, transmitted,
transcribed, stored in a retrieval system, or any of its part translated
into any language or computer le, in any form or by any means—
electronic, mechanical, magnetic, optical, chemical, manual, or
otherwise—without express written permission and consent from
Cypress Technology.
© Copyright 2015 by Cypress Technology.
All Rights Reserved.
TRADEMARK ACKNOWLEDGMENTS
All products or service names mentioned in this document may be
trademarks of the companies with which they are associated.

SAFETY PRECAUTIONS
Please read all instructions before attempting to unpack, install or
operate this equipment and before connecting the power supply.
Please keep the following in mind as you unpack and install this
equipment:
• Always follow basic safety precautions to reduce the risk of re,
electrical shock and injury to persons.
• To prevent re or shock hazard, do not expose the unit to rain,
moisture or install this product near water.
• Never spill liquid of any kind on or into this product.
• Never push an object of any kind into this product through any
openings or empty slots in the unit, as you may damage parts
inside the unit.
• Do not attach the power supply cabling to building surfaces.
• Use only the supplied power supply unit (PSU). Do not use the PSU
if it is damaged.
• Do not allow anything to rest on the power cabling or allow any
weight to be placed upon it or any person walk on it.
• To protect the unit from overheating, do not block any vents or
openings in the unit housing that provide ventilation and allow for
sufcient space for air to circulate around the unit.
REVISION HISTORY
VERSION NO. DATE (DD/MM/YY) SUMMARY OF CHANGE
RDV1 30/07/15 Preliminary release
RDV2 03/08/16 Draft manual
RDV3 07/09/16 Updated texts and images
RDV4 01/08/17 Updated sections 6.7 & 6.9

CONTENTS
1. Introduction............................................ 1
2. Applications........................................... 1
3. Package Contents ................................ 1
4. System Requirements............................ 2
5. Features.................................................. 2
6. Operation Controls and Functions....... 3
6.1 Front Panel ........................................3
6.2 Top Panel ..........................................6
6.3 Bottom Panel ....................................7
6.4 Left Panel ..........................................7
6.5 Right Panel........................................7
6.6 Remote Control................................8
6.7 OSD Menu.......................................10
6.7.1 Analyzer Mode......................10
6.7.2 Pattern Mode ........................16
6.7.3 Test Timings ............................21
6.7.4 Test Patterns...........................25
6.8 RS-232 Protocol...............................42
6.9 RS-232 and Telnet Commands .....42
6.10 Telnet Control ...............................60
7. Connection Diagram .......................... 61
8. Specications ...................................... 62
8.1 Technical Specications ...............62
8.2 Supported Color Formats..............63
8.3 Supported Audio Formats .............63
9. Acronyms ............................................. 64

1
1. INTRODUCTION
The HDMI Signal Generator & Analyzer is an advanced and handy
tool for generating, testing and verifying the signal path within your
18Gbps HDMI ecosystem. With 87 built-in resolutions, 56 test patterns
and over a dozen types of A/V analysis functions, this unit provides
an enormous range of testing options. HDMI data packet, EDID and
HDCP analysis is supported along with EDID upload and emulation.
Additionally the Status and Control Data Channel (SCDC) can be
monitored, allowing HDMI 18Gbps signal detection and analysis. Up to
8 channels of LPCM audio test tones can be generated with a wide
range of frequencies. This unit also supports the ability to upload up
to 2 user-generated graphic les which can be used as additional
test patterns. The use of multi-function and multi-color backlit buttons
allows for easy operation of the unit’s wide variety of functions and a
clear OLED display provides a way to quickly view the current signal
status information. In addition to the front panel buttons, the unit can
also be controlled via RS-232, Telnet, and IR providing a complete
range of control options.
2. APPLICATIONS
• Installer/Integrator multi-function test tool
• HDMI source and sink testing
• UHD system/SCDC error identication
• Third-party equipment setup
• Source and sink EDID reading, writing and saving
• HDCP compliance verication
• Production testing
• R&D design and testing
3. PACKAGE CONTENTS
• 1×HDMI Signal Generator & Analyzer
• 1×Remote Control (CR-174)
• 1×DC to USB Type-A Power Cable
• 1×5V/2.6A Power Adaptor
• 1×Operation Manual

2
4. SYSTEM REQUIREMENTS
• HDMI/VGA receiving equipment such as an HDTV, monitor or audio
amplier and/or HDMI source equipment such as a media player,
video game console or set-top box.
• Analog audio source equipment such as a PC or media player
and/or analog audio receiving equipment such as headphones, an
audio amplier or powered speakers.
• RS-232 or Ethernet control device such as PC/Laptop. (Optional)
• USB enabled device for uploading user test patterns.
5. FEATURES
• HDMI 2.0 (up to 4K@60Hz 4:4:4) and DVI 1.0 compliant
• HDCP 1.4 and 2.2 compliant
• Analysis of source and sink data paths up to 18Gbps HDMI signals
• Analysis of HDMI data packets
• Analysis and control of HDCP v1.4 and v2.2
• Analysis and emulation of EDID data, including SCDC
• Analysis of input audio signals
• HDR bypass and analysis support
• Generate HDMI timings up to 18Gbps (4096×2160@60Hz 4:4:4, 8-bit)
• Generate HDMI and VGA signal outputs
• VGA output supports 350p, 480p, 576p, 720p, 1080i, 1080p, 640×480,
800×600, 1024×768, 1280×1024, 1366×768, 1400×1050, 1440×900,
1600×900 (RB), 1600×1200, 1680×1050, 1920×1200 (RB), 2048×1080p
• HDMI output supports 350p, 480p, 576p, 720p, 1080i, 1080p, 640×480,
800×600, 1024×768, 1280×1024, 1366×768, 1400×1050, 1440×900,
1600×900 (RB), 1600×1200, 1680×1050, 1920×1200 (RB), 3G4K, 6G4K
• 2 custom user test pattern resolutions - 640×480 & 1920×1080
• External stereo audio input and output
• Generation of LPCM sinewave audio on up to 8 channels
• Front-panel, RS-232, Telnet, and IR Remote controls
• OLED display with rapid updates of current status information

3
• Detailed OSD for settings and informational displays
• Supports USB rmware and pattern update
• Small and portable unit
6. OPERATION CONTROLS AND FUNCTIONS
6.1 Front Panel
FACTORY
RESET
MENU ENTER
OPTION
COLOR
SPACE TIMING PATTERN
HDCP
PATTERN
EDID
PATTERN
DEEP
COLOR
OUTPUT
FORMAT
ANALYSER
/ PATTERN
HDCP
ON/OFF
AUDIO
LPCM
-
+
HDCP2.2
No Signal
5V=0 CKDT=0 SCDT=0
1
8
5
6
7
4
2
1512
10 1413119
3
1OLED Screen: Displays the current signal analysis information or
test pattern mode selection details including input and/or output
resolution timing. The screen layout changes depending on the
unit’s mode.
Analyzer Mode (ANALYZER/PATTERN button is RED): In Analyzer
mode, if there is no live video source detected on the input port,
the OLED will display any voltage, TMDS or sync that might be
present. Once a live video signal is detected, the unit will display
that signal’s current timing, format, HDCP version, AV Mute status,
color space, color depth and audio format.

4
No Signal
5V=0 CKDT=0 SCDT=0
TMDS clock
detection
+5V pin
detection
Sync signal
detection
1920x1080p24 3D HDMI
HDCP1 M Y444 12B LPCM
Resolution
HDCP
1.4/2.2
Color
depth
Color
space
General control
package
Audio
HDMI/DVI3D
Pattern Mode (ANALYZER/PATTERN button is BLUE): In Pattern
mode, when the output isn’t connected to a sink, the unit will
display the current output timing, RxSense, and Hot-plug detection
status. Once an active sink has been connected, the lower portion
of the display will change to indicate the current test pattern
number and name.
T62 1080p59
Sink RSEN=0 HPD=0
Hot plug
detection
RxSense
detection
Sink
T62 1080p59
P06 Colorbar S.
Test pattern
Test timing
2IR Window: Accepts IR signals from the included IR remote for
control of this unit only.
3MENU: Press to enter the OSD menu, or to back out from menu
items.
4ENTER/OPTION: Press to conrm a selection or to go deeper into a
menu item. When the selected function has optional selections,
the associated button’s LED will illuminate along with the ▼/▲ (-/+)
buttons.
5 +/- & ▲/▼: Press to move up and down or adjust selections within
menus. These buttons will illuminate when the selected function
has values that can be adjusted up or down.

5
6PATTERN: Within Pattern mode, press to enable selection of the
test pattern used. The ▼/▲ buttons will illuminate and are used
to select the new pattern. The new test pattern will automatically
become active after selecting it and pausing for 2 seconds.
Additional variations (if available) are selected by pressing the
PATTERN button additional times. Within Analyzer mode, press to
turn on/off a “title-safe/action-safe” overlay.
7TIMING: Press to enable selection of the output timing and
resolution used. The ▼/▲ buttons will illuminate and are used to
select the new timing. The currently selected timing will be shown
on the OLED display. The new timing will automatically become
active after selecting it and pausing for 2 seconds.
Note: In Analyzer mode, please select the “Bypass” timing if you
do not wish for your source’s output signal to be scaled by the unit
before being sent to the display. The TIMING button’s LED will blink
Red when the timing is set to Bypass.
8ANALYZER/PATTERN: Press to switch the unit between Analyzer
Mode (LED=Red) and Pattern Mode (LED=Blue). When in Analyzer
Mode, press and hold the button for 2 seconds to force an RX
hot-plug. When in Pattern Mode, press and hold the button for
2 seconds to turn on/off the AVMute bit within the output’s GCP
(General Control Packet).
FACTORY RESET: Press and hold this button while powering the unit
on to perform a factory reset of the unit.
9EDID PATTERN: Press to enable selection of the EDID to use on the
HDMI input port. The ▼/▲ buttons will illuminate and are used to
select the new EDID. The currently selected EDID will be shown on
the OLED display. The new EDID will automatically become active
after selecting it and pausing for 5 seconds.
10 AUDIO LPCM: Within Analyzer mode, press to select which digital
audio source pair (0~3) is routed to the primary stereo channel
(LPCM 2.0 and headphone output) for monitoring. The LED color
indicates the selection (Off=SD0, Red=SD1, Blue=SD2, Purple=SD3).
Within Pattern mode, press to switch between LPCM 2.0
(LED=Red), 5.1 (LED=Blue) and 7.1 (LED=Purple) channel test tone
output formats. Press and hold this button for 2 seconds to allow
adjustment of the output volume.
11 HDCP PATTERN: Press to enable/disable the OSD display of the
Altri manuali per CPHD-V4
2
Indice
Altri manuali CYP Strumento di misura