Datacolor ELREPHO Manuale utente

Datacolor
Datacolor ELREPHO
User’s Guide

Datacolor ELREPHO User’s Guide (August, 2005) Part No. 4230-0398M Rev 1
All efforts have een made to ensure the accuracy of the information presented in this format.
However, should any errors e detected, Datacolor appreciates your efforts to notify us of
these oversights.
Changes are periodically made to this information and are incorporated into forthcoming versions.
Datacolor reserves the right to make improvements and/or changes in the product(s) and/or program(s)
descri ed in this material at any time.
Copyright © 2005 Datacolor. ALL RIGHTS RESERVED. This material may not e reproduced or
duplicated, in whole or in part, without the express written permission of Datacolor.
Microsoft®, MS-DOS®, and Microsoft Windows® are registered trademarks of Microsoft Corporation.
All other registered trademarks are the property of their respective owners.
Support Questions?
If you need help with a Datacolor product, please contact one of our top-rated technical support teams
located around the world for your convenience. You can find contact information elow for the
Datacolor office in your area.
Americas
+1.609.895.7465
+1.800.982.6496 (toll-free)
+1.609.895.7404 (fax)
Europe
+41.44.835.3740
+41.44.835.3749 (fax)
Asia Pacific
+852.2420.8606
+852.2420.8320 (fax)
Or Contact our Local Representative
Datacolor has representatives in over 60 countries. For a complete list, visit
www.datacolor.com/locations.
Manufactured by Datacolor
288 Shengpu Road, Suzhou Industrial Park, Suzhou, China
+86 512 625 80338

ELREPHO User's Guide Contents • i
Contents
Datacolor ELREPHO ......................................................................................... 1
A out the Datacolor ELREPHO ....................................................................................1
Feature Summary .........................................................................................................2
Accessories ..................................................................................................................2
Calibration Tiles ....................................................................................................2
Aperture Plates .....................................................................................................3
Ultra-Violet (UV) Filters.................................................................................................3
Electrical/Environmental Requirements ........................................................................3
Cable Installation .............................................................................................. 5
Overview ......................................................................................................................5
Power Ca le Installation ...............................................................................................5
Serial Ca le Installation ................................................................................................6
USB Ca le Installation..................................................................................................6
Cable Installation ...................................................................................................7
Driver Installation...................................................................................................7
Viewing/Changing Syste Port Assign ent .........................................................9
Changing the COM Port Assign ent in Datacolor Progra s .............................. 13
Installing Calibration Data ................................................................................... 13
Controls and Indicators .................................................................................. 15
Identification of Controls/Indicators ............................................................................ 15
Status Panel ............................................................................................................... 15
Powering Up ............................................................................................................... 16
Instrument Calibration ................................................................................... 17
Overview .................................................................................................................... 17
Installing Calibration Data ................................................................................... 17
Reflectance Cali ration .............................................................................................. 18
Reflectance Calibration Procedure ...................................................................... 19
UV Filter Calibration ............................................................................................ 19
Sample Presentation/Measurement ............................................................... 21
A out Sample Presentation/Management .................................................................. 21
Sample Presentation .................................................................................................. 22
Sample Viewing Port .................................................................................................. 22
Changing Aperture Plates .......................................................................................... 23
Tile Maintenance............................................................................................. 25
A out Tile Maintenance .............................................................................................. 25
Handling Tiles ............................................................................................................. 25
Cleaning Tiles ............................................................................................................. 25
Tile Storage ................................................................................................................ 26
Cleaning the Black Trap ............................................................................................. 26
Appendix ......................................................................................................... 27
Optical Block Diagram ................................................................................................ 27
Datacolor Elrepho Optical Block Diagram .................... Error! Bookmark not defined.
Instrument Specifications ........................................................................................... 28
Miscellaneous Technical Information ......................................................................... 29
RS-232C Connector Pin Assign ents ................................................................ 29
Compliance Statements ............................................................................................. 29
FCC Co pliance State ent ................................................................................ 29
Canadian Co pliance State ent ........................................................................ 29
Index ............................................................................................................... 31


ELREPHO User's Guide Datacolor ELREPHO • 1
Datacolor ELREPHO
About the Datacolor ELREPHO
The Datacolor ELREPHO is a color-measuring instrument designed specifically for use y the paper
industry. It incorporates the state-of-the-art CMOS integrated circuit technology used in other Datacolor
instruments, and employs a vertical mount design. It is intended for use as a device for measuring,
specifying and evaluating color in oth la oratory and production settings.
Below is a summary of the standard and optional features included with the Datacolor ELREPHO.
Standard features include the following:
• Pulsed xenon light source
• Multiple aperture sizes to accommodate samples of different sizes
• Automated zoom lens
• Automated, adjusta le ultra-violet filter used to control the UV component in the light source
• Automated UV cut-off filters for three wavelengths
Please refer to Appendix, Instru ent Specifications for co plete instru ent specifications.

2 • Datacolor ELREPHO ELREPHO User's Guide
Feature Summary
The Datacolor ELREPHO employs state-of-the-art features including the spectrometer, integrating
sphere, light source, and optics. Below is a summary of those features:
FEATURE DESCRIPTION PURPOSE/BENEFIT
Integrating sphere Barium coated sphere.
Industry standard.
Measurement
Geometry
Diffuse illumination, 0º
viewing
Conforms to the instrument specification
found in ISO 2469 standard.
SP2000 Spectral
Analyzer
Proprietary dual-
channel holographic
grating. 256-
photodiode linear
arrays used for oth
the reference and
sample channels.
Dual channel design provides continuous
monitoring of sample illumination and
compensates for changes. 256-photodiode
array enhances the precision of the
measurement.
Light source Pulsed xenon flash
lamp
Filtered to provide D65 illumination
including UV component.
Effective Bandwidth 10nm Reporting interval is 10nm. Maintains
consistency with reporting interval.
Accessories
The Datacolor ELREPHO comes with the following standard accessories:
Cables Calibration Accessories
• Six foot power ca le
• Serial ca le with connectors on either end
• USB ca le
• Black trap
• White tile
• Green tile
Calibration Tiles
A lack trap, white tile and green tile are provided with the instrument:
• The lack trap and white tile are used each time the instrument is cali rated.
• The green tile is used to perform an optional diagnostic test during instrument cali ration

ELREPHO User's Guide Datacolor ELREPHO • 3
Aperture Plates
Three aperture plates, with openings of different sizes, are included as standard accessories. The
identification is engraved on each plate.
Aperture Plates Designations
• Extra-Large Area View (XLAV)
• Small Area View (SAV)
• Ultra Small Area View (USAV)
Below are aperture plate specifications:
Aperture
Identification
Sample Area
Measured
Sample Area
Illuminated
XLAV 30mm 34.0 mm
SAV 5mm 9.0 mm
USAV 2.5mm 6.5 mm
NOTE
The area illuminated is always 4mm greater than the diameter measured, to reduce
translucency errors.
Tips for Aperture Selection
• Always use the largest possi le aperture size.
• Small (SAV) and ultra-small (USAV) plates should only e used for measurements of samples
that do not completely cover the opening of the larger aperture plates.
Ultra-Violet (UV) Filters
The Datacolor ELREPHO is fitted with an adjusta le UV filter to control the amount of ultra-violet light
present in the light source, and with UV cutoff filters used to cutoff specific wavelengths. Refer to the
Datacolor TOOLS User’s Guide Instrument Menu, UV Calibration and Advanced Options, UV
Calibration and Whiteness for detailed instructions on the cali ration and use of these filters.
Electrical/Environmental Requirements
Power 85 to 264 VAC, 47 to 63 Hz, 80 VA peak, 35 VA typical
Absolute Operating Environment 5º to 40º C, 20-85% RH, non-condensing
Interfaces Serial: RS232 9600/19200 aud
USB: 1.1

4 • Datacolor ELREPHO ELREPHO User's Guide
N O T E S

ELREPHO User's Guide Ca le Installation • 5
Cable Installation
Overview
WARNING
Read “Electrical and Environ ental Require ents” section before connecting your Datacolor
instru ent.
The Datacolor ELREPHO requires the use of two ca les, a power ca le and a communications ca le
(either serial or USB ca le) to connect the instrument to the computer.
The connections for these ca les are found on the ack of the instrument.
Power Cable Installation
Power is supplied to the ack of the unit via a 3-prong male connector. A six-foot power ca le is
provided with the instrument.
To connect the ca le:
1. Plug the female end of the power cord into the power receptacle on the rear panel of the
instrument.
2. Insert the plug into a standard AC outlet.
Serial cable
Power cable
USB cable

6 • Ca le Installation ELREPHO User's Guide
Serial Cable Installation
The serial ca le is shown elow:
1. Connect the 9-pin male connector on the serial ca le to the RS-232C female connector on the
rear panel of the instrument.
2. Connect the female connector on the serial ca le to a serial communications port on the ack
of the computer.
3. If there is more than one serial port on the computer, make a note of the port eing used. You
may need to enter this information into the program.
4. Tighten each connection securely to ensure proper signal.
See the Appendix for a description of the RS-232C connector pin assign ents.
USB Cable Installation
Instruments manufactured y Datacolor can now e connected to a USB port on a desktop system.
See Appendix, Syste Require ents for USB Cable Installation efore you attempt to connect to a
USB port.
Before ou Begin
• Close all programs currently running on the system.
• You will need the accessories listed elow to complete the installation:
− USB cable (provided y Datacolor)
− Datacolor CD ROM disk la eled USB Drivers and Docu entation (Datacolor Part
#2052-0330).
− Calibration diskette or CD included with the instrument (this is required only when
installing new instruments)
Indice
Altri manuali Datacolor Strumento di misura

Datacolor
Datacolor SpyderPRINT Manuale utente

Datacolor
Datacolor ColorReaderPRO DC10-1 Manuale utente

Datacolor
Datacolor Spyder3 Elite Guida di riferimento

Datacolor
Datacolor 45 Manuale di programmazione

Datacolor
Datacolor 20D Manuale utente

Datacolor
Datacolor 45 Manuale di programmazione

Datacolor
Datacolor ColorReader EZ Manuale utente

Datacolor
Datacolor SpyderPRINT Manuale utente

Datacolor
Datacolor 45 Manuale utente

Datacolor
Datacolor Elrepho 3000 Manuale utente