Desert Aire GreenAire Manuale utente

Indoor Air Quality
Aura™ (QS)
TotalAire™ (QS)
VerticalAire™ (QV)
• Climate control
systems that provide
cooling, dehumidifi-
cation, and optional
auxiliary heating for
Controlled Environ-
mental Agriculture in a
single, highly efficient
package.
• The GrowAire®GA
Series climate control
system offers a
all-in-one packaged
rooftop configuration.
• The GrowAire®GS
Series climate control
system is available in
a wide range of indoor
and outdoor configura-
tions and sizes to
match the application
requirements.
• The GrowAire®GV
Series climate control
system is a high-quality
cost-effective system
designed for tight
spaces
GreenAireTM
Climate Control Systems
Installation and Operation Manual
• Water system for use
with chilled/hot water
• CEA specic controls
• Unique control over
internal water ow
and temperature
• Internal chilled water
recirculation pump
• Internal chilled water
and hot water valves
Indoor Air Quality
Aura™ (QS)
TotalAire™ (QS)
VerticalAire™ (QV)
Installation and Operation Manual
• Climate control
systems that provide
cooling, dehumidifi-
cation, and optional
auxiliary heating for
Controlled Environ-
mental Agriculture in a
single, highly efficient
package.
• The GrowAire®GA
Series climate control
system offers a
all-in-one packaged
rooftop configuration.
• The GrowAire®GS
Series climate control
system is available in
a wide range of indoor
and outdoor configura-
tions and sizes to
match the application
requirements.
• The GrowAire®GV
Series climate control
system is a high-quality
cost-effective system
designed for tight
spaces
GS Series™
GV Series™
GA Series™

2

3
DANGER
ONLY TRAINED, QUALIFIED PERSONNEL SHOULD INSTALL AND/OR SERVICE
DESERT AIRE EQUIPMENT. SERIOUS INJURY, DEATH AND PROPERTY DAMAGE CAN
RESULT FROM IMPROPER INSTALLATION/SERVICE OF THIS EQUIPMENT. HIGH VOLTAGE
ELECTRICAL COMPONENTS AND REFRIGERANT UNDER PRESSURE ARE PRESENT.
For any unit labeled Class 1, Group D, Division 2, all wiring must be in accordance to
Class 1, Group D, Division 2 requirements. Insure that all local, state, national and any
other applicable codes are adhered to when connecting any device to this equipment.
All electrical connections to units labeled Class 1, Group D, Division 2 must be done
with a conduit seal.
Desert Aire
Climate Control Equipment Standard Limited Warranty
Desert Aire warrants the climate control unit to be free from defects in materials and workmanship subject to the
terms, conditions and limitations stated herein.
TERMS
Desert Aire warrants all components (except as noted) for a period of two (2) years from the date of shipment. This
warranty shall be limited to the supply of new or rebuilt parts for the part which has failed because of
defects in workmanship or material, and does not include the cost for labor, transportation or other costs not herein
provided for. Replaced parts are warranted only for the remaining portion of the original warranty period.
CONDITIONS
The warranty is subject to the following conditions:
1. The unit must be properly installed and maintained in accordance with the Desert Aire
“Installation and Operation Manual” provided with each unit and/or other documentation provided.
2. The Start-Up Report must be completed and returned to Desert Aire Service for evaluation. If no
decienciesareidentiedaWarrantyValidationLetterwillbeissuedthatprovidesallwarrantydates
andcoverage.Ifinstallationorstart-updecienciesarepresent,thesemustbecorrectedand
communicated to Desert Aire in order to activate warranty.
3. This warranty shall not apply to any part that has been tampered with, or has been subject to
misuse, negligence or accident. A warranty can be obtained for altered equipment but only with
written consent from Desert Aire.
4. The following parts and components are excluded from the warranty: belts, lters, driers, fuses.
Desert Aire - GreenAire™ Manual

4
5. Coils or other components that corrode due to corrosive air quality will not be warranted.
6. All replacements or repairs will be FOB Germantown, WI.
7. This warranty shall be null and void if defects or damages result from
tampering with factory set controls,
or operating outside the original design conditions.
8. Desert Aire shall not be liable for labor costs incurred in diagnosing the problem, or the removal
or replacement of the part or parts being repaired.
9. Desert Aire must preauthorize all warranty coverage described herein.
Extended Warranty:
Your Desert Aire unit may have extended warranties beyond this Standard Limited Warranty document.
Extended warranties are only available at the time of the purchase of the original equipment. These extended
warranties are covered under a separate document and their terms and conditions are separate from this
document. It is mentioned in this document for informational purposes only. Any Extended Warranties will be
identied on the Warranty Validation letter.
Any and all incidental or consequential damages are expressly excluded from this warranty. Some states do not allow
the exclusion of incidental or consequential damages for personal injury, so the above limitations may not apply to you
for certain damages. This warranty gives you specic legal rights, and you may also have other rights, which vary
from state to state. No person or representative is authorized to make any warranty or assume any liability not strictly
in accordance with the aforementioned.
Inquiries regarding warranty matters should be addressed to:
Desert Aire Corp c/o Service Manager
N120 W18485 Freistadt Road • Germantown, WI 53022 USA
Additional copies of this manual can be purchased for a nominal fee from Desert Aire. Submit requests to the contact
information listed above.
Desert Aire - GreenAire™ Manual

5
Safety Labels are used throughout this manual. They comply with the ANSI Z535.4 Standard.
Pleasebefamiliarwiththefollowinglabelsandtheirdenitions.
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow this
symbol to avoid possible death or injury.
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, could result in minor or moderate injury.
Caution used without the safety alert symbol indicates a
potentially hazardous situation which, if not avoided, could
result in property damage.
Product Warning for the State of California
Desert Aire - GreenAire™ Manual

6
TABLE OF CONTENTS
1 Introduction ................................................................................................................................. 9
1.1 Inspection ...................................................................................................................... 9
1.2 Freight Damage Claims ............................................................................................... 9
1.3 Rigging .......................................................................................................................... 9
1.3.1 Rigging the Unit ................................................................................................. 9
2 Installation
..................................................................................................................................
12
2.1 Location and Access ...................................................................................................... 12
2.2 Duct Installation ............................................................................................................ 13
2.3 Condensate Drain Piping .............................................................................................. 14
2.4 Unit Door Access and Lock ........................................................................................... 16
2.5 Water Piping Installation ................................................................................................ 18
2.6 High Voltage Wiring
......................................................................................................
21
2.6.1 High Voltage Connections ................................................................................. 21
2.6.2 Wire and Fuse Sizing ........................................................................................ 22
2.7 Controls and Sensors
...................................................................................................
22
2.7.1 Zone Sensor ...................................................................................................... 23
2.7.2 Photo Sensor ..................................................................................................... 24
2.7.3 Remote Display Terminal (Optional) .................................................................... 25
2.7.4 CO2 Sensors (Optional) ........................................................................................ 26
3. Start-Up Procedure ................................................................................................................... 29
3.1 Preliminary Inspection ................................................................................................... 29
3.2 Principle of Operation .................................................................................................... 29
3.3 Airow Balancing ........................................................................................................... 30
3.3.1 Blower Adjustment Procedure ........................................................................ 31
3.4 System Testing .............................................................................................................. 31
3.4.1 Dehumidication / Cooling Mode .................................................................... 32
3.5 General Testing
............................................................................................................
32
3.6 Routine Maintenance Schedule
...................................................................................
33
3.6.1 Service Every Month ........................................................................................ 33
3.6.2 Service Every Six Months ..................................................................
..............
34
3.6.3 Service Every Year .............................................................
..............................
34
4 Troubleshooting
........................................................................................................
..................
35
4.1 The Fan Does Not Run .................................................................................................. 35
4.2 The Pump Does Not Run ............................................................................................... 35
5 Appendix
......................................................................
................................................................
37
5.1 Recommended Duct Design ...
........................................................................................
37
5.2 Recommended Controller Settings
................................................................................
38
5.3 GreenAire™ Sequence of Operation
.............................................................................
38
5.3.1 Basic Sequence
......................................................................................................
38
5.4 Component Replacement, Drain & Leak Instructions
....................................................
41
5.5 System Rating Plate ...................................................................................................... 42
5.6 Start-Up Suppervision Supplemental Information
.........................................................
43
Desert Aire - GreenAire™ Manual

7
5.7 System Start-Up Report
..................................................................
..............................
44
Start-Up Request Form ................................................................................................ 45
GR Series Start-Up Report
.............................................................................
..............
47
Desert Aire - GreenAire™ Manual

8Desert Aire - GreenAire™ Manual

9
1. Introduction
Desert Aire climate control units are designed to provide years of reliable service when installed
properly. Read these instructions carefully before you install the unit.
1.1. Inspection
Desert Aire inspects and tests each climate control unit before it leaves the factory so that you
receive a quality piece of equipment. Unfortunately, equipment may become damaged in
transit. Inspect the unit carefully before signing the receiving papers. Check for both visible and
concealed damage. Remove crating and inspect the exterior cabinet for damage. Dented
panels, broken crating or any uid leaking from the unit should be documented upon delivery.
1.2. Freight Damage Claims
Freight is shipped FOB, if damage is noted, the BOL must be marked damaged to process a
claim - Failure to do so will void any future claims
If the unit has been damaged, document the extent of the damage. Take pictures if possible.
Next, obtain a claim form from the carrier. Promptly ll out and return the form. Carriers may
deny claims that you have not lled out within a week of delivery. Notify Desert Aire of any
damage. Damaged units must have signed documents at the time of delivery to be eligible
for a freight claim.
1.3. Rigging
1. Failure to observe rigging instructions may lead to equipment damage, personal
injury, or death.
2. Lifting method and procedure must comply with all local and national codes and
regulations.
3. The use of safety slings in addition to lifting lugs is required.
4. Do not lift the dehumidifier in high winds or above people.
Desert Aire equipment is solidly built and can be very heavy. Avoid personal injury and damaging
the equipment by planning the installation carefully. Use moving equipment whenever possible.
1.3.1. Rigging the Unit
Depending upon the unit type, various rigging methods are used to best lift the
equipment. Please reference the applicable sections below:
Desert Aire - GreenAire™ Manual

10
• GreenAire™ Products (GR)
-Vertical Cabinet Models (GRAV,GRBV,GRCV,GRDV)
Personnel should avoid stepping on the top of the unit. Desert Aire
air handlers are not designed to support the weight of a person on all
portions of the roof. Damage incurred through caved or distorted top
panels will not be covered under warranty. If you must walk on the top
panels, carefully walk on the edges where structural integrity is
greatest.
Figure 1 - Fork Pocket Locations
Desert Aire - GreenAire™ Manual
Indice