5
© Dinel, s.r.o. CLM–36
• CLM–36_–10 Non-insulated rod electrode, for measuring the level of electrically non-
conductive liquids (oil, diesel, gasoline) and bulk solid materials (our, sand,
cement, plastic granules, etc.).
Electrode length from 0.2 m to 5 m (for materials with low permittivity εr <10,
the minimum electrode length is 0.5 m).
• CLM–36_–11 Insulated rod electrode (PFA), suitable for measuring the level of water and
other electrically conductive liquids. Also suitable for contaminated liquids in
metal tanks, concrete pits, etc.
Electrode length from 0.2 m to 3 m.
• CLM–36_–12 Insulated rod electrode (FEP), suitable for measuring the level of water and
other electrically conductive liquids. Also suitable for contaminated liquids in
metal tanks, concrete pits, etc.
Electrode length from 0.2 m to 3 m.
• CLM–36_–20 Non-insulated rod electrode with reference tube, to measure the level of
unpolluted and electrically non-conductive liquids (oil, diesel, gasoline).
Electrode length from 0.2 m to 3 m.
• CLM–36_–22 Insulated rod electrode with reference tube, for measuring the level of
clean electrically conductive liquids (e.g. in plastic and glass tanks) and for
greater demands on measurement accuracy. Electrode insulation made of
FEP material. Electrode length from 0.2 m to 3 m.
• CLM–36_–30 Non-insulated stainless steel rope electrode and weights, for measuring
the level of loose materials (sand, our, cement, etc.) Possibility of shortening
the rope. Electrode length from 1 m to 20 m.
• CLM–36_–31 Non-insulated stainless steel rope electrode and insulated dynamic
anchorage, to measure the level of bulk materials in higher silos.
Electrode length from 1 m to 20 m.
• CLM–36_–32 Insulated rope electrode (FEP) with insulated weight (FEP), designed to
measure the level of electrically conductive and non-conductive liquids.
Electrode length from 1 m to 15 m.