ETS-Lindgren EMCenter Manuale utente

EMCenter™
Modular RF Platform
User Manual

ii www.ets-lindgren.com
ETS-Lindgren Inc. reserves the right to make changes to any product described
herein in order to improve function, design, or for any other reason. Nothing
contained herein shall constitute ETS-Lindgren Inc. assuming any liability
whatsoever arising out of the application or use of any product or circuit
described herein. ETS-Lindgren Inc. does not convey any license under its
patent rights or the rights of others.
© Copyright 2013–2016 by ETS-Lindgren Inc. All Rights Reserved. No part
of this document may be copied by any means without written permission
from ETS-Lindgren Inc.
Trademarks used in this document: The ETS-Lindgren logo is a registered
trademark, and EMCenter, EMSwitch, EMPower, EMControl, EMSense, EMLink,
TILE!, and EMQuest are trademarks of ETS-Lindgren Inc.
Revision Record | MANUAL, EMCenter | Part #399342, Rev. C
Revision Description Date
A Initial Release July, 2013
B Updated EMCenter models June, 2014
C Updated USB Driver installation
instructions
November, 2016

www.ets-lindgren.com iii
Table of Contents
Notes, Cautions, and Warnings ............................................... vi
1.0 Introduction .......................................................................... 7
EMCenter Plug-In Cards (Optional) ............................................................................... 8
EMSwitch RF Switch Plug-In Card ........................................................ 8
EMPower Plug-In Card and EMPower Sensors .................................... 9
EMControl Positioner Control Plug-In Card ......................................... 10
EMSense EMF Probe Plug-In Card ..................................................... 10
EMGen RF Signal Generator Plug-In Card ......................................... 11
Standard Configuration ................................................................................................ 11
ETS-Lindgren Product Information Bulletin .................................................................. 12
2.0 Maintenance ....................................................................... 13
Maintenance of Fiber Optics ........................................................................................ 14
Service Procedures ...................................................................................................... 14
3.0 Specifications ..................................................................... 15
Performance Specifications ......................................................................................... 15
Physical Specifications ................................................................................................ 15
Environmental Specifications ....................................................................................... 15
Power Specifications .................................................................................................... 16
Interface and Cable Specifications .............................................................................. 16
4.0 Laser Safety ........................................................................ 17
Safety Precautions ....................................................................................................... 17
Safety Features ............................................................................................................ 18
5.0 EMCenter Controls and Connectors ................................ 19
Front Panel .................................................................................................................. 1 9

iv www.ets-lindgren.com
Status Indicators .................................................................................. 19
Back Panel ................................................................................................................... 2 0
6.0 Installation .......................................................................... 23
Plug-In Card Installation ............................................................................................... 23
7.0 Manual Control of the EMCenter ...................................... 25
Common Control Buttons ............................................................................................. 25
Powering On and Off ................................................................................................... 26
Power On ............................................................................................. 26
Power Off ............................................................................................. 27
Information Screen ....................................................................................................... 28
Home Screen ............................................................................................................... 29
Card Slot Numbers .............................................................................. 29
Status Box ........................................................................................... 30
Control Buttons .................................................................................... 30
Local Mode .......................................................................................... 30
Configuration Screen ................................................................................................... 31
8.0 Remote Control of the EMCenter ..................................... 33
First Character: Identifier ............................................................................................. 33
Second Character: Device ID Number ......................................................................... 34
Command Examples .................................................................................................... 35
Example 1: Request Device Identification ........................................... 35
Example 2: Request an E-Field Reading ............................................ 35
Example 3: Request a Power Value .................................................... 35
Command Set and Error Codes ................................................................................... 36
Command Set ...................................................................................... 36
Error Codes ......................................................................................... 36
Using the USB Interface .............................................................................................. 37

www.ets-lindgren.com v
Download USB Drivers ........................................................................ 38
If Your Computer is Installed with Windows 7, 8, or 10 ....................... 38
To Change the COM Port Assignment ................................................ 39
Appendix A: Warranty ............................................................. 41
Appendix B: EC Declaration of Conformity .......................... 43

vi www.ets-lindgren.com
Notes, Cautions, and Warnings
Note: Denotes helpful information intended to
provide tips for better use of the product.
Caution: Denotes a hazard. Failure to follow
instructions could result in minor personal injury
and/or property damage. Included text gives proper
procedures.
Warning: Denotes a hazard. Failure to follow
instructions could result in SEVERE personal injury
and/or property damage. Included text gives proper
procedures.
See Laser Safety on page 17 for detailed laser safety precautions and
operational features.
See the ETS-Lindgren Product Information Bulletin for safety,
regulatory, and other product marking information.

www.ets-lindgren.com Introduction 7
1.0 Introduction
For flexible configuration of an EMC test facility and fully-automated testing, the
ETS-Lindgren EMCenter™ Modular RF Platform provides space for up to
seven plug-in cards in a 3U, 19-inch rack mount enclosure. The EMCenter can
also be used as a desktop unit.
The EMCenter is available in the following configurations:
Model 7000-001: 7-slot EMCenter Modular RF Platform
Model 7000-010: 7-slot EMCenter Modular RF Platform with GPIB
Model 7000-011: 2-slot EMCenter Modular RF Platform with GPIB
The slots can contain a user-defined combination of these ETS-Lindgren cards:
EMSwitch™, EMPower™, EMControl™, and EMSense™. When installed, each
card is automatically recognized, initialized, and ready for use. For more
information on the cards, see EMCenter Plug-In Cards (Optional) on page 8.
The EMCenter is configured and controlled using the 7-in widescreen color
thin-film transistor (TFT) touchscreen on the front panel. Additionally, the
EMCenter may be controlled from a computer using these software products:
ETS-Lindgren TILE!™ (Totally Integrated Laboratory Environment)
ETS-Lindgren EMQuest™ Data Acquisition and Analysis Software
Other test automation software

8Introduction www.ets-lindgren.com
The EMCenter contains a Vortex-embedded main processor to control all cards
and to interface with the user and/or an external computer. The operating system
is Linux-based, providing a stable operating environment, fast startup time, and
high performance. All embedded software is stored in flash, making it easy to
upgrade to new versions and future functionality.
EMCenter Plug-In Cards (Optional)
EMS
WITCH
RF S
WITCH
P
LUG
-I
N
C
ARD
EMSwitch is a general purpose multi-channel switch matrix used to switch the RF
path of equipment for RF measurement applications, including immunity,
emissions, and wireless measurements. EMSwitch is available with two SPDT
coaxial relays, four SPDT coaxial relays, or two SP6T coaxial relays; a 40 GHz
option is also available. EMSwitch cards switch RF signals from DC–18 GHz,
with powers up to 240 W.
Model 7001-001 Model 7001-003 Model 7001-002
(not all models shown)

www.ets-lindgren.com Introduction 9
EMP
OWER
P
LUG
-I
N
C
ARD AND
EMP
OWER
S
ENSORS
The EMPower Meter Plug-in Card occupies one slot in the EMCenter and
includes four USB ports, accommodating any combination of up to four EMPower
USB RF Power Sensors.
Two versions of the EMPower sensors are available:
Model 7002-002 and Model 7002-004: Support RMS measurements
for CW signals.
Model 7002-003 and Model 7002-005: Measure RF bursts as short as
a few microseconds.
The 7002-002 and 7002-003 sensors cover the 9 kHz to 6 GHz range, and the
7002-004 and 7002-005 sensors cover the 80 MHz to 18 GHz.

10 Introduction www.ets-lindgren.com
EMC
ONTROL
P
OSITIONER
C
ONTROL
P
LUG
-I
N
C
ARD
EMControl is a versatile positioner controller
which enables you to synchronize the
simultaneous movements of up to two
ETS-Lindgren positioning devices
(for example, towers or turntables) and the
on/off operation of an additional auxiliary
device, such as a LISN or EUT.
EMS
ENSE
EMF P
ROBE
P
LUG
-I
N
C
ARD
The EMSense card provides an interface for
ETS-Lindgren battery-powered EMC field
probes. Each EMSense card can support
one probe.
Indice
Altri manuali ETS-Lindgren Strumento di misura

ETS-Lindgren
ETS-Lindgren HI-1801 Manuale utente

ETS-Lindgren
ETS-Lindgren HI-1501 Manuale utente

ETS-Lindgren
ETS-Lindgren HI-4433 Manuale utente

ETS-Lindgren
ETS-Lindgren HI-3627 Manuale utente

ETS-Lindgren
ETS-Lindgren HI-3604 Manuale utente

ETS-Lindgren
ETS-Lindgren HI-6122 Manuale utente

ETS-Lindgren
ETS-Lindgren HI-1501 Manuale utente

ETS-Lindgren
ETS-Lindgren OMS Manuale utente

ETS-Lindgren
ETS-Lindgren HI-3638 Manuale utente

ETS-Lindgren
ETS-Lindgren HI-2200 Manuale utente