www.event-lighting.com.au
4. Mode. Set the trigger mode. Press Up/Down to select between the available modes, and
press Enter to confirm. The available modes are:
a. NO_TR: Normally Open. The trigger will be activated when the circuit is closed.
The show will be played in a loop until the circuit is opened again, upon which it
will stop when the current playback is complete.
b. NC_TR: Normally Closed. The trigger will be activated when the circuit is opened.
The show will be played in a loop until the circuit is closed again, upon which it
will stop when the current playback is complete.
c. NCBK_TR: Same as NC_TR, but when the trigger is activated, it will prevent
button input and other triggers from being activated until the playback is
complete.
d. NOBK_TR: Same as NO_TR, but when the trigger is activated, it will prevent
button input and other triggers from being activated until the playback is
complete.
e. TOGGLE_TR: The first trigger activation will start the show and play it in a loop.
A second trigger activation will stop the show, and a subsequent trigger activation
will start the show again.
f. Auto_TR: The trigger will be activated automatically when the device is started.
5. Delay. Set the delay time before the event starts after the trigger is activated. Press
Up/Down to select the delay time, between 0 and 120 seconds.
After configuring the parameters, use Up/Down to scroll to the bottom and select Confirm and
Save to save the configuration or Cancel and Return to discard changes.
Stop TR Event
Activate or deactivate trigger events.
Press Up/Down to select a trigger and press Enter to activate or deactivate the selected trigger.
Device Settings
View and edit device settings. Press Up/Down to select between the following settings and press
Enter to edit it.
Device Label. The visible name of the device. Press Up/Down key to select a character, Enter to
select that character, and Up/Down to change that character. Once the desired character is
displayed, press Enter to confirm. Once the desired name is inputted, select Enter and press
Enter to save.
• DMX Port Option. Press Up/Down to select between the following options:
o Single: Only the last triggered show will be displayed.
o HTP (Highest takes precedence): all triggered shows are played simultaneously.
The DMX value of each channel is merged into the DMX output, which contains
the highest value of each DMX channel.
Press Enter to confirm.
• Display Option. Press Up/Down to select between the following options, and press Enter
to modify the selected option:
o Mode:
§ Normal: Display is in it’s normal configuration.
§ Inverse: Display is flipped vertically. The order of Menu/Up/Down/Enter
will also become reversed.
o GoBack(s): The time in seconds after which the display will return to the start
screen if no button input is received. Range: 5-60 seconds, in increments of 5
seconds, or Never.
o Backlight(s): The time in seconds after which the display will turn off if no button
input is received. Range: 5-60 seconds, in increments of 5 seconds, or ON (the
display will always remain on).