Exhausto VEX370H Manuale utente

VEX370H
Mechanical Assembly - EXact2 control system
Product information............................................................... Chapter 1 + 6
Mechanical assembly............................................................ Chapter 2 + 3
Electrical installation.............................................................. Chapter 4
Maintenance.......................................................................... Chapter 5
Original brugsanvisning
3004793-2023-04-18
EXHAUSTO A/S
Odensevej 76
5550 Langeskov, Denmark
Tel.: +45 65 66 12 34
Fax: +45 65 66 11 10
www.exhausto.dk

1. Product information
1.1. Designations used in these instructions..............................................................................................5
Model overview............................................................................................................................... 5
1.1.1. Designations used in these instructions..........................................................................................6
1.2. Application.............................................................................................................................................. 7
1.3. Location requirements........................................................................................................................... 7
1.3.1. Space requirements........................................................................................................................8
1.3.2. Requirements for underlying surface.............................................................................................. 8
1.3.3. Outlet............................................................................................................................................. 8
1.3.4. Requirements for duct system........................................................................................................ 8
1.4. Description.............................................................................................................................................. 9
1.4.1. Design.............................................................................................................................................9
1.5. Main aim.................................................................................................................................................11
1.5.1. Dimensional drawing.....................................................................................................................11
2. Handling
2.1. Unpacking............................................................................................................................................. 14
2.1.1. Once the VEX has arrived ........................................................................................................... 14
2.1.2. Weight...........................................................................................................................................14
2.1.3. Weight...........................................................................................................................................14
2.2. Transport............................................................................................................................................... 15
2.2.1. Passage through openings ......................................................................................................... 15
2.2.2. Internal transport with reduced weight.......................................................................................... 16
2.2.3. Disassembly of integrated heating coil, HCW370I .......................................................................19
3. Mechanical assembly
3.1. Installing the unit.................................................................................................................................. 20
3.1.1. Assembly instructions................................................................................................................... 20
3.1.2. Step 1–4........................................................................................................................................22
3.2. Condensation drain.............................................................................................................................. 27
3.2.1. Establishment of condensation outlet........................................................................................... 27
3.3. Integrated water heating coil............................................................................................................... 28
3.3.1. Principles for connecting the water heating coil............................................................................28
3.3.2. Bleeding of coils............................................................................................................................29
3.3.3. MVM valve.................................................................................................................................... 30
4. Electrical installation
4.1. Electrical installation............................................................................................................................32
5. Maintenance
5.1. Operating readings via the HMI panel................................................................................................ 33
5.2. Maintenance Schedule......................................................................................................................... 33
5.3. Hygiene..................................................................................................................................................34
5.4. Service................................................................................................................................................... 34
5.4.1. Filter change................................................................................................................................. 34
5.4.2. Removing the counter flow heat exchangers...............................................................................34
5.4.3. Servicing and cleaning..................................................................................................................37
6. Technical data
6.1. Weight, corrosion class, temperature ranges, etc.............................................................................39
6.2. Compact filters......................................................................................................................................40
6.3. Bag filters.............................................................................................................................................. 41
6.4. Ingenerated water heating coil HCWi................................................................................................. 41
6.4.1. MVM motor valve ......................................................................................................................... 42
6.5. Capacity diagram via EXselectPro......................................................................................................42
6.6. Ordering spare parts............................................................................................................................ 43
3004793-2023-04-18
2/44

Symbols, terms and warnings
Prohibition symbol Failure to observe instructions marked with a prohibition symbol may result in
serious or fatal injury.
Danger symbol Failure to observe instructions marked with a danger symbol may result in per-
sonal injury and/or damage to the unit.
Scope This instruction manual is for use with EXHAUSTO VEX-type air handling units. Please refer to the
product instructions regarding accessories and extra equipment.
The instructions must be fully observed to ensure personal safety and to protect the equipment and
ensure its correct operation. EXHAUSTO A/S accepts no liability for accidents caused by equipment
not used in accordance with the manual’s instructions and recommendations.
Supply air/extract
air
These instructions use the following terms as given in DS447-2013:
● Supply air (air blown in)
● Extract air (air removed)
● Outdoor air
● Exhaust air
Left/Right The term R for Right, indicates the supply air is to the right of the cooling unit, as seen from the operat-
ing side. The term L for Left, indicates the supply air is to the left.
Front page: Acces-
sories
The front page of the instruction manual contains a checklist, detailing the accessories delivered with
the VEX unit.
NB When retrofitting EXHAUSTO accessories, please update the checklist on the front page.
Warnings
Opening the air
handling unit
Do not open the service doors until the supply voltage has been disconnected at
the isolation switch and the fans have stopped. The isolation switch is positioned
on the left side of the connection box on top of the unit.
RD13497-01
ON OFF
No duct connection If one or more of the spigots is not connected to a duct: Fit a protective net to the
spigots with a maximum mesh width of 20 mm (in accordance with EN294).
3004793-2023-04-18
3/44

Lock the air han-
dling unit during
operation
The VEX unit must always be locked during op-
eration:
● Use the cylinder lock in the handle. Re-
member to remove the key from the lock.
● Or use a padlock. Use the handle’s built-in
padlock fixture
Lås
Hængelåsbeslag
Rating plate The VEX unit rating plate shows:
● VEX model (1)
● Production order no. (2)
1
2
NB Always have the production number ready when contacting EXHAUSTO A/S.
3004793-2023-04-18
4/44

1. Product information
1.1 Designations used in these instructions
Model overview
Elements Explanation
RD12767-01
Fan
RD13531-01
Compact filter
RD12762-01
Bag filter
1,1,A or B Extract air spigot
NB: In cases where the unit has two spigots (extract air/
flue gases), the filter is always located by the extract air
spigot
1,2,A Exhaust air spigot
2,1,A Outdoor air spigot
2,2,A or B Supply air spigot
11
Air direction, extract air
22
Air direction, supply air
NB The sketch shows compact filters
Fan placement Air directions
LEFT
RD13532-01
1,1,A
2,1,A
2,2,A
1,2,A
1,1,B
2,2,B
1
2
3004793-2023-04-18 Product information
5/44

Fan placement Air directions
RIGHT
RD13533-01
1,1,A
2,1,A
2,2,A
1,2,A
1,1,B 2,2,B
1
2
NB Spigot location B option not available with outdoor models.
1.1.1 Designations used in these instructions
The simplified diagram shows a VEX unit with LEFT fan placement.
Component Function
BP1 Bypass damper extract air/exhaust air
BP2 Bypass damper outdoor air/supply air
BP3 Bypass shut-off dampers supply air
BT40/BT50 Fire thermostat, 40℃/50℃ (extract air)
BT70 Fire thermostat 70℃ (supply air)
MC1 Motor control, motor 1 (extract air)
MC2 Motor control, motor 2 (supply air)
HMI Control panel
HCWI Integrated water heating coil
LS Closing damper, outdoor air/exhaust air
M1 Extract air motor
M2 Supply air motor
MIO-CO2-DUCT CO2 sensor, duct
MIO-CO2-ROOM CO2 sensor, room
MIO-PIR PIR sensor
MIO-RH-ROOM Humidity sensor
3004793-2023-04-18 Product information
6/44

Component Function
MIO-TS-ROOM Temperature sensor, room
MIO-TS-DUCT Temperature sensor, extract air (external)
MPT1, P1 Airflow control, extract air
MPT1, P2 Filter monitor, extract air
MPT2, P1 Airflow control, supply air
MPT2, P2 Filter monitor, outdoor air
MPT3, P1 Ice detection
MPT-DUCT Pressure transmitter, constant pressure regulation
TE11 Temperature sensor, extract air
TE12 Temperature sensor, exhaust air
TE21 Temperature sensor, outdoor air
TE22 Temperature sensor, supply air
1.2 Application
Comfort ventilation EXHAUSTO VEX is used for comfort ventilation tasks. Operating temperature range for the unit – see
section "Technical data".
Prohibited uses The VEX unit is not to be used to transport solid particles or in areas where there is a risk of explosive
gases.
1.3 Location requirements
Positioning The air handling unit is designed for indoor fitting. The air handling unit can be ordered for outdoor in-
stallation (accessory Outdoor, OD).
3004793-2023-04-18 Product information
7/44

1.3.1 Space requirements
The drawing below indicates how much space is required to open the side-mounted doors for servicing,
replacing filters, cleaning, etc. The drawing shows compact filters.
2200
415
1366
RD13499-01
NB For servicing purposes, a free height of at least 200 mm is required above the unit’s connection box.
1.3.2 Requirements for underlying surface
When floor-mounting the unit, the surface must be:
● level (+/- 10 mm per metre)
● hard
● resistant to vibration
The VEX unit leg height can be adjusted: 55–110 mm.
1.3.3 Outlet
A condensation outlet must be installed in the immediate vicinity of the unit. See also “Mechanical fitting”
section.
1.3.4 Requirements for duct system
Silencers The duct system must be fitted with silencers specified by the Project Manager, which meet the re-
quirements of the operating area.
Bends A duct bend may be fitted immediately after the unit, because the airflow in the spigot has a uniformly
moderate speed profile, which results in negligible system pressure loss.
Insulation The duct system must be insulated against:
3004793-2023-04-18 Product information
8/44

● condensation
● sound leakage
● heating/cooling losses
Condensation Condensation in the ducts may occur when the exhaust/outdoor air has high humidity. EXHAUSTO
recommends a condensation outlet is also fitted at the lowest point in the ducts.
No duct connection If one or more of the spigots is not connected to a duct: Fit a protective net to the
spigots with a maximum mesh width of 20 mm.
1.4 Description
1.4.1 Design
Layout drawing,
Left model
The drawing below illustrates the construction of the unit, without doors:
The drawing shows compact filters.
1
3
45678910
12 13 15 1714 18 20
2,1,A 1,2,A
1,1,A
2,2,A
RD13500GB-01
2
11 16
1,1,B/ue gas
2,2,B
19
Layout drawing,
Right model
The drawing below illustrates the construction of the unit, without doors:
The drawing shows compact filters.
3004793-2023-04-18 Product information
9/44

13
1095 6 7 84
3
12
1
1517 141820
2,1,A
1,2,A
1,1,A
2,2,A
RD13501GB-01
2
1116
1,1,B/ue gas 2,2,B
19
Pos. no. Part Function
1 Spigot 1,1,A Extract air spigot The spigot can also be positioned on the top
of the unit (1,1,B). Does not apply to units designed for outdoor
fitting
2 Spigot 1,2,A Exhaust air spigot
3 Closing damper LS Closing damper, exhaust air, LSA (accessory).
4 Fan unit, exhaust air Removes "stale" air
5 Motor control, extract air
fan
Variably adjusts fan
6 MPT1 Measurement of pressure in extract air duct
7 Counterflow heat ex-
changer
6 counter flow heat exchangers made from aluminium, conduct
the heat from extract air to supply air
8 Outdoor air filter Filters outdoor air.
9 Spigot 2,1,A Outdoor air spigot
10 Closing damper LS Closing damper, outdoor air, LSF (accessory).
11 Integrated heating coil Heats supply air if heat recovery is insufficient (accessory).
12 Spigot 2,2,A Supply air spigot. The spigot can also be positioned in the top
of the unit (2,2,B). Does not apply to units designed for outdoor
fitting
13 Fan unit, supply air Blows air into the room
14 Motor control, supply air
fan
Variably adjusts fan
15 MPT2 Measures pressure in supply air duct
16 Connection box Connection box for supply voltage, external ventilation compo-
nents, HMI panel, BMS and Ethernet
17 Connection box Cover plate
18 HMI panel Operation of the control system
3004793-2023-04-18 Product information
10/44
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Exhausto Sistema di controllo

Exhausto
Exhausto VEX150CF H Manuale utente

Exhausto
Exhausto VEX260HX Manuale utente

Exhausto
Exhausto EXact2 HMI2-350-TOUCH Guida all'installazione

Exhausto
Exhausto VEX320C Manuale utente

Exhausto
Exhausto VEX200 series Guida all'installazione

Exhausto
Exhausto EBC11 Manuale utente

Exhausto
Exhausto EXact2 VEX240 series Guida all'installazione

Exhausto
Exhausto EXact2 HMI2-350-TOUCH Guida all'installazione

Exhausto
Exhausto EXact2 VEX240 series Guida all'installazione

Exhausto
Exhausto VEX160 Series Manuale utente