TABLE OF CONTENTS
WBECS COMPONENT DIAGRAM....................................2
WBECS DIAGRAM REFERENCE TABLE........................3
WARRANTY INFORMATION.............................................4
WBECS SYSTEM OVERVIEW...........................................5
WBECS KIT CONTENTS ..................................................5
TOOLS/SUPPLIES REQUIRED FOR INSTALLATION....5
INSTALLATION REQUIREMENTS...................................6
GAS INSTALLATION REQUIREMENTS ........................6
GAS TYPE....................................................................6
GAS PRESSURE.........................................................6
GAS LINE SIZING........................................................6
GAS CONNECTION.....................................................6
GAS ORIFICE SIZING .................................................6
ELECTRICAL INSTALLATION REQUIREMENTS.........7
POWER SUPPLY REQUIREMENTS...........................7
POWER TRANSFORMER REQUIREMENTS.............7
WIRE SIZE REQUIREMENTS.....................................7
ELECTRICAL CONNECTIONS....................................8
WIRING OF MULTIPLE WBECS UNITS .....................8
PHYSICAL INSTALLATON REQUIREMENTS...............9
CLEARANCE REQUIREMENTS .................................9
PILOT INSTALLATION REQUIREMENTS.................. 9
MEDIA REQUIREMENTS.......................................... 10
VENTILATION REQUIREMENTS................................. 10
DETAILED INSTALLATION INSTRUCTIONS ............... 11
ELECTRICAL CONNECTIONS................................. 11
GAS CONNECTIONS...........................................11-12
ELECTRONIC IGNITION CONTROL TESTING ....... 13
WBECS OPERATION..................................................... 14
GENERAL OPERATION............................................ 14
BULLETED GENERAL OPERATION........................ 14
FIRE FEATURE START UP...................................... 14
FIRE FEATURE SHUTDOWN................................... 14
DESCRIPTION OF IGNITION & TIMINGS................ 15
MAINTENANCE .............................................................. 15
TROUBLESHOOTING................................................15-18
Electrical Current:....................................................... 16
LED Diagnostic Codes............................................... 16
TROUBLESHOOTING FLOW DIAGRAM ............18-20
PARTS LIST & ACCESSORIES...................................... 21
WARRANTY INFORMATION
Flame-tec warrants the Weather Beater Electronic Control
System (WBECS) to be free of manufacturing defects in materials
or workmanship when properly installed and operated for
residential use for a period of two (2) years from date of
installation. If installed in a commercial setting, this warranty
period is for one (1) year. Date of installation must be
documented, or the date of manufacture as shown on the
example label at right. The date of manufacture is shown above
the CSA logo with a two-digit year followed by a two-digit week shall be considered the warranty commencement date.
During the warranty period, Flame-tec will repair or replace any components, that in its sole discretion are considered
defective. This warranty covers parts only and does not cover costs of removal, reinstallation, shipping or inspection of said
parts.
Damage to the WBECS caused by installation error, accident, misuse, or abuse is not covered under this warranty. Any
modification to the WBECS or any of its components as supplied by the factory will void the warranty. Under no
circumstances will Flame-tec be responsible for incidental or consequential damages. Limitations to incidental and
consequential damages vary from state to state so some limitations may not apply to you.
To file a warranty claim, owner must contact Flame-tec or authorized dealer with:
Name, Address, Telephone Number, Date and Proof of Purchase, Date and Proof of Installation, and Model
Name/Part number
Please explain installation particulars and defect noted. Pictures of installation may be required.
Flame-tec reserves the right to inspect components and may require part(s) to be returned to the factory for inspection.
If in its sole discretion Flame-tec finds a component or system to be defective, it will repair or replace said components with
new or remanufactured parts as it deems appropriate. Transportation charges to and from Flame-tec are the responsibility
of the owner.
For questions or help in diagnosis or installation please call Flame-tec support at 844-352-6383 or visit the website at
www.flame-tec.com.