Flomotion Systems LT260 Manuale utente

LT260
Ultrasonic Level Transmitter
Operation and Maintenance Manual

2

3
TABLE OF CONTENTS
1. SYSTEM INTRODUCTION ................................................................................................. 4
1. Receiving and Inspection of Product and Packaging.......................................................... 4
2. Safety and Operation........................................................................................................... 4
3. Warranty ............................................................................................................................. 4
2. TECHNICAL SPECIFICATIONS ....................................................................................... 5
3. INSTALLATION.................................................................................................................... 6
1. General................................................................................................................................ 6
4. WIRING & POWER .............................................................................................................. 8
5. INITIAL START-UP & DISPLAY....................................................................................... 9
6. PROGRAMMING ................................................................................................................ 10
PROGRAMMING MODE ..................................................................................................... 12
[P01] Measurement Type.................................................................................................. 12
[P02] Unit of Measure ...................................................................................................... 12
[P03] Display Measurement Value................................................................................... 12
[P04] Empty Distance ....................................................................................................... 12
[P05] Dead Zone ............................................................................................................... 13
[P06] 4mA Set Point ......................................................................................................... 13
[P07] 20mA Set Point ....................................................................................................... 13
[P08] mA Fail-Safe Value ................................................................................................ 13
[P09] mA Fail-Safe Time.................................................................................................. 13
[P10] Dampening .............................................................................................................. 14
[P11] Detection Threshold Voltage .................................................................................. 14
[P12] Output Power .......................................................................................................... 14
[P13] Sound Velocity........................................................................................................ 15
[P14] Vapor Temperature Compensation ......................................................................... 15
[P15] Detection Algorithm ............................................................................................... 15
[P16] Detection Target...................................................................................................... 15
[P17] Current Output Simulation...................................................................................... 16
[P18] Password ................................................................................................................. 16
7. MAINTENANCE.................................................................................................................. 16

4
1. SYSTEM INTRODUCTION
1. Receiving and Inspection of Product and Packaging
When opening the LT260 packaging, inspect all cartons for damage that may have
occurred during shipping. Carefully unpack equipment and inspect thoroughly for
damage or shortage. Report any damage to carrier and/or shortages to supplier. DO
NOT discard any boxes or packaging if damage has occurred.
2. Safety and Operation
In the interest of safety, the installation and operation of the LT260 shall be
performed by licensed or qualified professionals. Before powering the LT260, please
read his manual thoroughly. Flomotion Systems is not responsible for accidents
caused by misuse or modification of the product.
3. Warranty
Flomotion Systems, Inc. warrants the LT260 Series to be free of defects in material
and workmanship for a period of one year from date of sale. Under normal use, if the
LT260 becomes defective within the stated warranty time period, contact Flomotion
Systems, Inc. for return authorization prior to returning any product. Flomotion
Systems, Inc. reserves the right to make the final determination as to the validity of a
warranty claim, and sole obligation is to repair or replace only components, which
have been rendered defective due to faulty material or workmanship. No warranty
claim will be accepted for components which have been damaged due to mishandling,
improper installation, unauthorized repair and/or alteration of the product, operation
in excess of design specifications or other misuse, or improper maintenance.
Flomotion Systems, Inc. makes no warranty that its products are compatible with any
other equipment, or to any specific application, to which it may be applied and shall
not be held liable for any other consequential damage or injury arising from the use of
its products. This warranty is in lieu of all other warranties, expressed or implied.
No other person, firm or corporation is authorized to assume, for Flomotion Systems,
Inc., any other liability in connection with the demonstration or sale of its products.

5
2. TECHNICAL SPECIFICATIONS
Dimensions 7.4d x 11.2h in. (188d x 284h mm)
Process Connection 3” NPT or Flanged
Housing Material Aluminum Alloy
Sensor Material PVDF
Weight 6.2 lbs (2.8 Kg)
NEMA Rating NEMA 6
Temperature -4°F to 158°F (-20°C to 70°C)
Measurement Range 26ft. (8m)
Accuracy 0.2% of F.S.
Display Resolution 0.04 in (1mm)
Beam Angle 8° at -3dB
Damping Rate Adjustable
Temperature Compensation Built-in
Analog Output 4-20mA, 550Ωat 24VDC
Display 5 Digit Numeric LCD
Power Supply 20 to 30VDC
Supply Current 0.022A
Certification CE

6
3. INSTALLATION
1. General
•Remove any obstacles between the sensor and measurement point.
•The bottom of the sensor should be perpendicular to the measurement point.
•Avoid mounting the sensor too close to a wall.
•Avoid setting a maximum level into the Dead Zone range.
•Avoid the exposure to direct sunlight.
•Avoid high voltage or high current lines.
•Install on solid, non-vibrating surface.
•LT260 shall be used in accordance with manufacturer’s specifications.
The bottom of the sensor should be
perpendicular to the surface of water.
When mounting the sensor, keep the distance
to the tank wall into consideration.

7
Installation with mounting bracket
Installation with threaded flange
NOTE: Do not exceed maximum nozzle length for recommended nozzle diameter. Nozzle
material must be seamless.
Nozzle Diameter (D) Maximum Nozzle Length (L)
3” (80mm) 9” (240mm)
4” (100mm) 12” (300mm)
6” (150mm) 17” (430mm)
8” (200mm) 22” (570mm)

8
4. WIRING & POWER
When powering the LT260 use 20-30Vdc. Wiring and power diagram for proper installation
below.
16A Connector
Cable
Terminal
block
1/2” Nipple
-
(+24V)
+

9
5. INITIAL START-UP & DISPLAY
The LT260 has two display modes; a measurement mode for displaying level and a programming
mode for application set-up.
Measure Mode:
In measurement mode, 4 LED’s are seen on the front panel of the LT260, shown below. A
Flashing “0” on the display is shown when it is in fault condition (Lost Echo).
LED Condition Function
Detect & Level Flashing together Indicates Normal Operation
Mode selected = Level
Detect & Distance Flashing together Indicates Normal Operation
Mode selected = Distance
Detect & Space Flashing together Indicates Normal Operation
Mode selected = Space
Level or
Distance or
Space
Flashing alone
Indicates that LT260 is detecting an
echo but checking if the value is
correct.
None All Off
Display indicates “E-Err”
Indicates that LT260 has gone into Fail
condition.
Reasons:
- There is no reflected echo received.
- Transducer and electronic part are
disconnected

10
6. PROGRAMMING
The “MENU” button is used to enter the programming mode. It is located below the LED
function on the display. In programming mode, a program number is shown on the LCD such as
P01, P02.
Programming Buttons
To enter the Program Mode simply press the “MENU” button >1 sec. Once in Program Mode,
The Level, Distance, and Space LED’s turn off. The software version will display and the Menu
P01 will appear. Use the Up/Down buttons to access each parameter.
Enter Program Mode
Enter specific parameter mode
Exit from programming mode and put into operating mode.
Accepts parameter settings when in programming mode.
Changes parameter option.
Increase a specific parameter setting.
Changes parameter option.
Decrease a specific parameter setting.