Frico 74684 Manuale utente

Control system FC
Quick Guide
FCDA - FC Direct, FCSA - FC Smart
FCPA - FC Pro, FCBA - FC Building
EN

FCBC
FCSC
FCDC FCWTAFCTXRF
FCLAP
FCSC10
FCRTX
FCSC10
FCOTX
FCBC10
FCBC05FCDCFCCF
FCPA - FC Pro FCBA - FC Building
FCBC10FCDCFCCF FCLAP
FCBC10FCDCFCCF FCLAP FCTXRF FCBC10FCDCFCCF FCBAP
FCCF control panel
2
FC Frico Control - Quick guide
74684
FCDA
89x89x26 mm (FCCF)
74685
FCSA
89x89x26 mm (FCCF)
74686
FCPA
89x89x26 mm (FCCF)
74687
FCBA
89x89x26 mm (FCCF)
FCDA - FC Direct FCSA - FC Smart
74694
FCRTX
39x39x23 mm
74695
FCOTX
39x39x23 mm
74699
FCLAP
89x89x26 mm
74718
FCBC05 5 m
74719
FCBC10 10 m
74720
FCBC25 25 m
74721
FCSC10 10 m
74722
FCSC25 25 m
17495
FCDC
74703
FCTXRF*
89x89x26 mm
74702 FCWTA
FCBAP 149x149x43 mm
EN
FC Control system
External room temperature sensor
Outdoor temperature sensor
Local access point for extra sensors and extended range
Extra communication cable, 5 m
Extra communication cable, 10 m
Extra communication cable, 25 m
Extra sensor cable, 10 m
Extra sensor cable, 25 m
Door contact
Indoor/outdoor wireless sensor (for FC Smart, FC Pro)
Return water temperature sensor
Building access point
Item
number
Type Description Dimensions
*The wireless sensor can be set up as outdoor or indoor sensor by a switch inside the sensor.
Control system content and accessories
The air curtain must be supplemented with a control system.
FC Direct, rst level control system
FC Smart, second level control system
FC Pro, third level control system
FC Building, BMS system
FC Control system helps to create many smart and energy saving features. In addition to our
four packages, components can be added to expand and customize the system.
Item
number
Type Description Dimensions

FC Frico Control - Quick guide
3
FC Direct - FCDA
PC Board
inside air
curtain
A1 A2 B1 B2
GND
GND
GND
GND
HI
HI
LO
LO
+12V
+12V
BUS 1 BUS 2
PELN
230V~
G12
Sensor
GND
HI
LO
+12V
BUS 1 BUS 2
GND
HI
LO
+12V
Control
Panel
Sensor
FCRTX
FCOTX
D1 D2
WTA
Actuator
24V
E1 E2 -+
Com NONC
BLK
GRY
RED
G12
Sensor
FCDC
SDM
(VPFC/VMFC)
PC Board inside
air curtain
230V~
FCRTX
Control Panel
FCDC
SDM
(VPFC/VMFC)
FCOTX

FC Frico Control - Quick guide
4
FC Smart - FCSA
PC Board
inside air
curtain
A1 A2 B1 B2
GND
GND
GND
GND
HI
HI
LO
LO
+12V
+12V
BUS 1 BUS 2
PELN
230V~
G12
Sensor
GND
HI
LO
+12V
BUS 1 BUS 2
GND
HI
LO
+12V
Control
Panel
Sensor
FCRTX
FCOTX
D1 D2
WTA
Actuator
24V
E1 E2 -+
Com NONC
BLK
GRY
RED
GND
HI
LO
+12V
BUS 1 BUS 2
GND
HI
LO
+12V
FCLAP
*
Set up in
Setup Guide
FCDC
SDM
(VPFC/VMFC)
FCWTA
Config
input*
PC Board
inside air
curtain
A1 A2 B1 B2
GND
GND
GND
GND
HI
HI
LO
LO
+12V
+12V
BUS 1 BUS 2
PELN
230V~
G12
Sensor
GND
HI
LO
+12V
BUS 1 BUS 2
GND
HI
LO
+12V
Control
Panel
Sensor
FCRTX
FCOTX
D1 D2
WTA
Actuator
24V
E1 E2 -+
Com NONC
BLK
GRY
RED
GND
HI
LO
+12V
BUS 1 BUS 2
GND
HI
LO
+12V
FCLAP
*
Set up in
Setup Guide
FCDC
SDM
(VPFC/VMFC)
FCWTA
Config
input*
PC Board inside
air curtain
230V~
Sensor
FCDC
SDM
(VPFC/VMFC)
*
Set up in
Setup Guide
Control Panel
FCWTA
FCLAP
Config
input*

FC Frico Control - Quick guide
5
FC Pro - FCPA
PC Board
inside air
curtain
A1 A2 B1 B2
GND
GND
GND
GND
HI
HI
LO
LO
+12V
+12V
BUS 1 BUS 2
PELN
230V~
G12
Sensor
GND
HI
LO
+12V
BUS 1 BUS 2
GND
HI
LO
+12V
Control
Panel
Sensor
FCRTX
FCOTX
D1 D2
WTA
Actuator
24V
E1 E2 -+
FCDC
Com NONC
FCWTA
BLK
GRY
RED
SDM
(VPFC/VMFC)
GND
HI
LO
+12V
BUS 1 BUS 2
GND
HI
LO
+12V
FCLAP
Config
input*
*
Set up in
Setup Guide
FCTXRF*
PC Board inside
air curtain
230V~
Sensor
FCDC
SDM
(VPFC/VMFC)
Config
input*
*
Set up in
Setup Guide
Control Panel
FCWTA
FCLAP FCTXRF*

FC Frico Control - Quick guide
6
FC Building - FCBA
PC Board inside
air curtain
230V~
FCRTX
Control Panel
FCDC
SDM
(VPFC/VMFC)
FCOTX
FCWTA
FCBAP
PC Board
inside air
curtain
A1 A2 B1 B2
GND
GND
GND
GND
HI
HI
LO
LO
+12V
+12V
BUS 1 BUS 2
PELN
230V~
G12
Sensor
GND
HI
LO
+12V
BUS 1 BUS 2
GND
HI
LO
+12V
Control
Panel
Sensor
FCRTX
FCOTX
D1 D2
WTA
Actuator
24V
E1 E2 -+
Com NONC
BLK
GRY
RED
S
G12
Sensor
GND
HI
LO
+12V
BUS 1 BUS 2
GND
HI
LO
+12V
FCBAP
OUTPUT
Modbus
E1 E2 -+
RunInd
E1 E2
OFF
E1 E2
R.Temp
E1 E2
S.Temp
E1 E2
FanSpd
E1 E2
Alarm RS485
INPUT
FCWTA
SDM
(VPFC/VMFC)

FC Frico Control - Quick guide
7
GND
GND
HI
HI
LO
LO
+12V
+12V
BUS 1 BUS 2
GND
GND
HI
HI
LO
LO
+12V
+12V
BUS 1 BUS 2
GND
GND
HI
HI
LO
LO
+12V
+12V
BUS 1BUS 2
Termination at PC Board
To reduce the risk of interference, the communication BUS should be terminated at each end, i.e. in the units
that are located at the start and at the end of the BUS respectively. On delivery, all buses are pre-connected
with a 120 Ohm resistor between terminals HI and LO on BUS2. When making further connections, remove the
resistor. As an alternative to resistance, the termination switch on the board can be set to the "ON" position.

FC Frico Control - Quick guide
8
EN
Start up
1.Check that all components and accessories are
enclosed.
2.Assemble and connect system, consult wiring
diagrams.
3.Power-up the system.
4.The system automatically identifies all components,
even when they are added at a later stage.
5.Connecting a new product must always be made
with the power off.
System solution
A system consists of a control panel, FCCF, as well as an
optional number (1-63) of units (air curtains, access points
or control panels) and sensors. The set-point temperature
and the fan settings for the system are selected on the
control panel.
The control panel houses a built-in temperature sensor
which can be used, alternatively the products or zones are
fitted with external room temperature sensors that have
better sensor positioning for local temperature control.
Heating blocked dependent on outdoor temperature
With outdoor temperature information (FCOTX / FCTXRF
/ outdoor temperature signal in FCBAP), heating is
automatically blocked when the outdoor temperature
exceeds 15 °C. The set point can be changed and this
function can be deactivated, see Settings.
C. System with several products with
external room sensors connected to each
product
External room temperature sensors
control each product, together with the
inlet sensor in each product.
D. System with several products, of which,
at least two products have external room
sensors and at least one product does not
have an external room sensor
External room temperature sensors control
each product it is connected to together with
the inlet sensor in each product. Products
without sensors are controlled by the control
panel's temperature sensor together with the
inlet sensor in each product.
A. System without external room sensors
The control panel's temperature sensor is
controlling together with the inlet sensor in
each product.
B. System with one external room sensor
One external room temperature sensor in
the system controls all products, together
with the inlet sensor in each product.

3
4
FC Frico Control - Quick guide
9
EN
Overview
Control panel
5
1
2
6
8
7
+
Press and hold (2 sec) Quick command
Display lock on/off
Display lock
Colour (LED)
White
OFF
Red flashing
Purple
Indicator Status (right-hand LED)
Heat on
Heat off
Alarm
Heating blocking
Colour (LED)
Indicator Operating Mode (left-hand LED)
During start-up, the text Inlt appears on
screen, then the current room temperature is
displayed.
When the screen is in standby mode, the light
intensity is reduced. Pressing any button will
simply display the set point temperature.
The FC control is delivered with preset values.
The preset set point temperature is 21 °C
and can be easily adjusted using the up/down
arrows.
Normal mode
Comfort mode
Comfort mode - temporary
Reduced (night mode)
Reduced (night mode) - temporary
Timer (activated in app)
Saving mode (activated in app)
Presence mode (activated in app)
OFF
White
White flashing
Green
Green flashing
Orange
Purple
Cyan
Keypad
1 Increase
2 Decrease
3 Menu / OK / Confirm
4 Fan
5 Cancel / Back
4 and 5 appear after pressing twice on menu
button.
Screen
6 Current room temperature (standby mode) /
Set point temperature (active mode)
Ambient air curtain: Fan setting
Indicators
7 Operating mode
8 Status
Status
Operating mode

FC Frico Control - Quick guide
10
EN
Fan speed when door is open
Press twice to activate keypad and hidden
buttons.
Press to set fan speed
Set the fan speed: 0-100-Auto / 0-3-Auto.
Auto requires outdoor temperature
information (FCOTX / FCTXRF / outdoor
temperature signal in FCBAP).
Fan menu
Browse between the menu options.
Confirm
Home screen
Press twice to activate keypad and hidden
buttons.
Exit without saving
or
Press and hold for 2 seconds.
See the table on the following page for the possible
choices.
Questo manuale è adatto per i seguenti modelli
12
Indice