Introduction
The handheld optical power meter is a fiber optic tester with compact size and
friendly operation interface. It has a wide range of power measurements and high
accuracy. When combining with a light source, it offers a quick and accurate
testing solution. The figures below display the product images of the two optical
power meters.
FOPM-203/FOPM-204
Accessories
FOPM-203/FOPM-204
USB Cable x1ST Adapter x1SC Adapter x1 FC Adapter x1
AC Adapter x1 CD x1
>2s PERM
>2s SAVE
>2sT WIN
OPTICAL POWER METER
>2s SET
REF
dBm/
dB/mw
ON
OFF
LOAD
DELETE
λ

EN
2
ON
OFF
LOAD
Button Description
Power Button
Wavelength Shift Button
Unit Shift Button
Value Storage Button
REF Setting Button
Backlight Control Button
λ
REF
dBm/
dB/mw
Function Introductions
>2s PERM
>2s SAVE
>2s TWIN
OPTICAL POWER METER
>2s SET
REF
dBm/
dB/mw
ON
OFF
LOAD
DELETE
λ

EN
3
Installing
2. Install FC fiber cable.
1. Remove dust cap.
Inserting FC Cables

EN
4
Inserting ST Cables
1. Install ST connector.
2. Install ST fiber cable.

EN
5
2. Install SC fiber cable.
1. Install SC connector.
Inserting SC Cables

2. Set Wavelength and Activate Auto-wavelength Recognition (TWIN)
Press the button repeatedly until the desired wavelength is displayed. You
can select from six possible wavelengths: 850nm, 1300nm, 1310nm, 1490nm,
1550nm, 1625nm.The instrument defaults to the wavelength which the user set
in the last test. When used with the FOLS-203 and FOLS-204 optical light source,
the wavelength will shift automatically according to the output wavelength of the
light source. Long press the button to activate the auto-wavelength
recognition and the "TWIN" will show on the LCD. Short press the button to
close the "TWIN".
3. Switch Measurement Mode
There are 3 measurement modes you can choose from by pressing the button
repeatedly, dB, dBm and mW.
4. Set Reference Level
(1) Press the button to display the stored reference level for the current
wavelength and a sign of“REF”will be displayed on the screen to indicate that it is
a reference value. The displayed value only lasts 1 second.
(2) Press and hold the button over 2 seconds to store the presently
1. Power On/Off and Auto-off Function
Press the button briefly. The instrument powers on, and the backlight
switches on. Press the button briefly again. The instrument powers off, and
backlight switches off.
EN
6
Operation Instructions
ON
OFF
ON
OFF
λ
NOTE: Auto-off function
(1) The instrument will power off automatically if 10 minutes
without any operation.
(2) While in the power-on state, press the button for about 2
seconds to turn off the“Auto-off”function.
ON
OFF
REF
REF
λ
λ
dBm/
dB/mw

2. Set Wavelength and Activate Auto-wavelength Recognition (TWIN)
Press the button repeatedly until the desired wavelength is displayed. You
can select from six possible wavelengths: 850nm, 1300nm, 1310nm, 1490nm,
1550nm, 1625nm.The instrument defaults to the wavelength which the user set
in the last test. When used with the FOLS-203 and FOLS-204 optical light source,
the wavelength will shift automatically according to the output wavelength of the
light source. Long press the button to activate the auto-wavelength
recognition and the "TWIN" will show on the LCD. Short press the button to
close the "TWIN".
3. Switch Measurement Mode
There are 3 measurement modes you can choose from by pressing the button
repeatedly, dB, dBm and mW.
4. Set Reference Level
(1) Press the button to display the stored reference level for the current
wavelength and a sign of“REF”will be displayed on the screen to indicate that it is
a reference value. The displayed value only lasts 1 second.
(2) Press and hold the button over 2 seconds to store the presently
EN
7
measured value as the new reference level for the current wavelength. During the
process, the“REF”sign flashes twice on the screen and buzzer sound is heard.
Once the new reference level is set, the instrument switches to the dB measure-
ment mode. The displayed value only lasts 1 second.
5. Switch Backlight of LCD On/ Off
Press the button . The backlight switches on.
Press the button again. The backlight switches off.
6. Frequency Detecting
If the tested wavelength is carrying a tone of 270Hz, 1kHz, or 2kHz, the respective
frequency indicates on the screen.
7. Overflow of Measured Power Value
If the measured power value is too high, the LCD screen will display“HI”.
If the measured power value is too low, the LCD screen will display “LO”.
8. Storage of Current Test Value
Press the button over 2 seconds, the “SAVE” flashes on the screen once with
the sounds of the buzzer. It indicates the setting is finished. It will display the
stored value and the serial number of the storage. Then, the power meter will
return to the test state automatically.
9. Check the Storage Records
Press the button , it will display the latest record.
Press the button , it will browse the forward records.
Press the button , it will browse the afterward records.
Press the button and , it will delete all the records.
LOAD
LOAD
λ
REF
REF

EN
8
Maintenance
(1) The interface is sensitive, please carefully plugin and pull out the adapter.
(2) Please cover the dust-proof cap when it is not in operation.
(3) Choose the correct fiber connector before testing.
(4) Take out the batteries when not in use.
(5) Please disconnect the AC adapter/charger once you finish using.
(6) Please keep all optical connectors and surface free from oil, dirt or other
contamination to ensure proper operation.
(7) Keep regular cleanings on the optical port of an optical power meter with
cotton swabs.
(8) To ensure the measurement accuracy, please send the instrument to FS for
calibration once a year.
Warranty: All Optical Power Meters enjoy 1 year limited warranty
against defect in materials or workmanship. For more details about
warranty, please check at https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can
be found at https://www.fs.com/policies/day_return_policy.html
1
Product Warranty
FS ensures our customers that any damage or faulty items due to our workman-
ship, we will offer a free return within 30 Days from the day you receive your goods.
Online Resources
Download
Support
Contact Us
https://www.fs.com/products_support.html
https://www.fs.com/service/fs_support.html
https://www.fs.com/contact_us.html

DE
9
Einführung
Dieser tragbare optische Leistungsmesser ist ein Glasfasertester mit kompakter
Größe und benutzerfreundlicher Bedienoberfläche. Er hat einen weiten Bereich
von Leistungsmessungen und eine hohe Genauigkeit. In Kombination mit einer
Lichtquelle bietet er eine schnelle und genaue Testlösung. Die Abbildungen
unten zeigen die Produktbilder der beiden optischen Leistungsmesser.
FOPM-203/FOPM-204
Zubehör
FOPM-203/FOPM-204
USB-Kabel x1ST-Adapter x1SC-Adapter x1 FC-Adapter x1
AC-Adapter x1 CD x1
>2s PERM
>2s SAVE
>2sT WIN
OPTICAL POWER METER
>2s SET
REF
dBm/
dB/mw
ON
OFF
LOAD
DELETE
λ
Questo manuale è adatto per i seguenti modelli
1
Indice
Lingue:
Altri manuali FS Strumento di misura