Gira One 5062 00 Manuale utente

Switching actuator 2-gang / blind actuator, 1-gang 16 A with binary input, 3-gang
Table of Contents
1 Safety instructions.............................................................................................................3
2 Device components...........................................................................................................4
3 Function ............................................................................................................................5
4 Information for electrically skilled persons ........................................................................7
4.1 Mounting and electrical connection........................................................................ 7
4.2 Commissioning .................................................................................................... 10
5 Technical data.................................................................................................................11
6 Accessories.....................................................................................................................12
7 Parameter list ..................................................................................................................13
8 Warranty..........................................................................................................................17
2 / 17
82404232 29.11.2022

1 Safety instructions
Electrical devices may only be mounted and connected by electrically skilled
persons.
Serious injuries, fire or property damage possible. Please read and follow manual
fully.
Danger of electric shock. Device is not suitable for disconnection from supply
voltage.
Danger of electric shock. Make sure during the installation that there is always suffi-
cient insulation between the mains voltage and the bus. A minimum distance of at
least 4 mm must be maintained between bus conductors and mains voltage cores.
Danger of electric shock on the installation. Do not connect any external voltage to
the inputs. The device might be damaged, and the SELV potential on the bus line will
no longer be available.
For parallel connection of several motors to an output it is essential to observe the
corresponding instructions of the manufacturers, and to use a cut-off relay if neces-
sary. The motors may be destroyed.
Use only Venetian blind motors with mechanical or electronic limit switches. Check
the limit switches for correct adjustment. Observe the specifications of the motor
manufacturers. Device can be damaged.
This manual is an integral part of the product, and must remain with the end cus-
tomer.
3 / 17
82404232 29.11.2022
Switching actuator 2-gang / blind actuator, 1-gang 16 A with binary input, 3-gang

2 Device components
Image1: Device components
(1) Programming LED
(2) Programming button
(3) Control cable (bus connection and extension inputs)
(4) Connection of load (relay outputs)
Image2: Connection assignment of control cable (example)
red (RD) KNX / One +
black (BK) KNX / One -
green (GN) Input 1 (push-button, switch, contact, condensation/leakage sensor)
yellow (YE) Input 2 (push-button, switch, contact, condensation/leakage sensor)
white (WH) Input 3 (push-button, switch, contact, condensation/leakage sensor,
NTC temperature sensor)
brown (BN) COM inputs 1...3
4 / 17
82404232 29.11.2022
Switching actuator 2-gang / blind actuator, 1-gang 16 A with binary input, 3-gang

3 Function
System information
This device is a product for the Gira One Smart Home system. The Gira One system
is commissioned easily and in a time-saving manner using the Gira Project Assistant.
The Gira One Smart Home system enables the control and automation of lighting,
heating and shading, as well as connection to various third-party systems and much
more. It can be operated via Gira One switches, by app from home or securely from a
remote location. Electrically skilled persons can maintain the Gira One project re-
motely free of charge.
Data transmission between the Gira One devices is encrypted. This provides protec-
tion against third-party access and manipulation.
Commissioning is carried out with the free Gira Project Assistant (GPA), version 5 or
higher. Free function and security updates are also transferred to the Gira One
devices with the GPA.
The Gira One system is based on the globally proven KNX smart home standard.
Intended use
– Operation in Gira One system
– Switching electrical loads via relay contacts with common reference potential
– Switching of electrically-driven Venetian blinds, roller shutters, awnings and
similar hangings
– Reading in switching states of installation switches or push-buttons and other
potential-free contacts at inputs 1...3
– Signal evaluation of condensation and leakage sensors at inputs 1...3 (see ac-
cessory).
– Acquisition of temperature values via NTC temperature sensor at input 3 (see
accessories)
– Mounting in appliance box with dimensions according to DIN 49073
Product characteristics
– Output can be operated via the Gira One system or extension inputs
– Three extension inputs for connecting potential-free contacts or dew/leakage
sensors. NTC temperature sensor can be connected to input 3.
– Supply via the bus, no additional supply voltage necessary
– Programming and commissioning with the Gira Project Assistant (GPA), ver-
sion 5 or higher
– Updating via the Gira Project Assistant (GPA)
– Encrypted data transmission between the Gira One devices
5 / 17
82404232 29.11.2022
Switching actuator 2-gang / blind actuator, 1-gang 16 A with binary input, 3-gang

Characteristics switch operation
– Operation as NO or NC contacts
– Setting of a switch-on or switch-off delay
– Staircase function for which a pre-warning time can additionally be set.
– Configuration as a switching function, e.g. for a light or sockets, as a garage
door function or door opener function, and as a switching contact for transmis-
sion of the heat requirement to a heat pump.
– Garage door function: The time for closing the relay can be configured.
– Door opener function: The time for closing the relay can be configured.
Characteristics blinds operation
– Control of blinds with slats, shutters, awnings, roof windows or roof domes.
– Travelling times can optionally be set.
– Sun protection function with blind or slat positions at the beginning and at the
end of the function can be set separately for each output.
– Setting of the delay time at the beginning or end of sunshine.
– Fabric stretching for awnings.
– If a wind alarm is active, e.g. with a conventional weather station with poten-
tial-free relay outputs for wind alarm, the Venetian blinds are raised and auto-
matically locked. The status of the binary input is monitored cyclically.
– If a rain alarm is active, e.g. with a conventional weather station with potential-
free relay outputs for rain alarm, roof windows or roof domes are closed and
automatically locked. The status of the binary input is monitored cyclically.
– If a frost alarm is active, e.g. with a conventional weather station with potential-
free relay outputs for frost alarm, active notions of shutters are stopped and
disabled to protect the shutter motor. The status of the binary input is mon-
itored cyclically.
– Door contact polling and visualisation in the Smart Home app: An open door
leads to the Venetian blind or shutters being raised and locked.
Extension input characteristics
– Single or dual-area operation can be configured for rockers.
– Connection of rockers that are configured with the function for switching, dim-
ming, shading & ventilation, scene recall, staircase (motion detector), floor call
with Gira G1, garage door and door opener.
– Connection of motion and presence detectors with potential-free relay outputs.
– Convenient group control of switching, dimming, shading and ventilation loads.
– Switching contact evaluation of wind, frost, brightness or rain sensors with po-
tential-free relay outputs possible in order to protect shading and ventilation
loads against environmental influences.
6 / 17
82404232 29.11.2022
Switching actuator 2-gang / blind actuator, 1-gang 16 A with binary input, 3-gang

– Window contact polling and visualisation in the Smart Home app: An open
window leads to the frost protection heating mode after a configured time has
elapsed.
– Door contact polling and visualisation in the Smart Home app: An open door
leads to the Venetian blind or shutters being raised and locked.
– Polling of a switch-over between heating/cooling at a heat pump in order to be
able to forward the current operating mode (heating or cooling) to a heating
controller.
– Switching contact indicator for displaying a contact state in the Smart Home
app.
– Configurable switching inputs that can be parameterised independently.
– Acquisition and calibration of temperature values via remote sensors (see ac-
cessories) at input 3.
4 Information for electrically skilled persons
DANGER!
Mortal danger of electric shock.
Disconnect the device. Cover up live parts.
4.1 Mounting and electrical connection
DANGER!
When connecting the bus/extensions and mains voltage wires in a shared appliance
box, the bus line may come into contact with the mains voltage.
This endangers the safety of the entire installation. People at remote devices may
also receive an electric shock.
Do not place bus/extensions and mains voltage terminals in a shared connection
compartment. Use an appliance box with a fixed partition wall or separate appliance
boxes.
Connecting and fitting the device
– Enter or scan the device certificate and add it to the project. A high resolution
camera should be used to scan the QR code.
– The device certificate should be removed from the device during mounting.
– Document all passwords and keep them safe.
Mounting in suitable appliance box (recommendation: electronic device box with par-
tition). Observe cable routing and spacing (see figure 3)!
7 / 17
82404232 29.11.2022
Switching actuator 2-gang / blind actuator, 1-gang 16 A with binary input, 3-gang

Image3: Mounting example in electronic appliance box with partition wall, series
push-button and NTC temperature sensor
(5) Appliance box
(6) Partition
(7) potential-free contacts (e.g. series push-button)
(8) NTC temperature sensor (optional)
Image4: Cable spacing
Minimum spacing between the mains voltage and bus/extension wires: 4 mm
(see figure 4)
8 / 17
82404232 29.11.2022
Switching actuator 2-gang / blind actuator, 1-gang 16 A with binary input, 3-gang

Image5: Connection of load
Observe ambient temperature. Ensure adequate cooling.
■ Connect bus line, observing the correct polarity.
■ Connect load as shown in the connection example (see figure 5).
■ If required, connect potential-free contacts or condensation/leakage sensors to
inputs 1...3, or NTC temperature sensors to input 3 (see figure 2).
■ Install the device in the appliance box.
The COM reference potential must not be connected together with COM con-
nections of other devices!
9 / 17
82404232 29.11.2022
Switching actuator 2-gang / blind actuator, 1-gang 16 A with binary input, 3-gang

4.2 Commissioning
Commissioning the device
NOTICE!
Incorrect load control due to undefined relay state at delivery.
Risk of destruction of connected drive motors.
During commissioning, before switching on the load, ensure that all relay contacts
are open by applying the bus voltage. Observe commissioning sequence!
■ Switch on the bus voltage.
■ Wait about 10 s.
■ Connect the load circuit.
Delivery state: The output is set as a Venetian blind output. Operation of the
blind output possible via input 1 (UP) and input 2 (DOWN). Input 3 has no
function.
Function of Inputs in the as-delivered state
Input Push-button (NO con-
tact)
Function
1 Press briefly (< 0.4 s) Stop
1 Press briefly (< 0.9 s) Adjusting the slats UP
1 Press for a long time (>
0.9 s)
Raise
2 Press briefly (< 0.4 s) Stop
2 Press briefly (< 0.9 s) Adjusting the slats DOWN
2 Press for a long time (>
0.9 s)
Lower
3 --- ---
The device is commissioned with the Gira Project Assistant (GPA) version 5 or
higher.
Safe-state mode
The safe-state mode stops the execution of the program.
Only the system software of the device is still functional. Diagnosis functions and pro-
gramming of the device are possible.
Activating safe-state mode
■ Switch off the bus voltage or disconnect the device from the bus.
■ Wait about 10 s.
■ Press and hold down the programming button.
10 / 17
82404232 29.11.2022
Switching actuator 2-gang / blind actuator, 1-gang 16 A with binary input, 3-gang
Indice
Altri manuali Gira Controllori

Gira
Gira 0570 00 Manuale utente

Gira
Gira System 3000 Manuale utente

Gira
Gira 5431 00 Manuale utente

Gira
Gira 0388 00 Manuale utente

Gira
Gira 0399 00 Manuale utente

Gira
Gira 0566 Series Manuale utente

Gira
Gira 1289 00 Manuale utente

Gira
Gira 2114 00 Manuale utente

Gira
Gira 2100 Series Manuale utente

Gira
Gira Powernet Switchactuator 2fold Manuale utente

Gira
Gira KNX 5061 00 Manuale utente

Gira
Gira 1039 00 Manuale utente

Gira
Gira 0309 00 Manuale utente

Gira
Gira G1 Manuale utente

Gira
Gira One 5061 00 Manuale utente

Gira
Gira KNX 213900 Manuale utente

Gira
Gira One Manuale utente

Gira
Gira 0425 00 Manuale utente

Gira
Gira 5023 00 Manuale utente

Gira
Gira 2101 Series Manuale utente