Hal Technology HFX205 Guida rapida

Page 1 of 24 V2.0
HAL-HFX205
Handheld Formaldehyde
Meter/Monitor
Operational Manual
7970 Cherry Avenue, Suite 303
Fontana, CA 92336 USA
Phone: (855) 438-4258 (toll-free)
Fax: (866) 402-9190 (toll-free)
http://haltechnologies.com

Page 2 of 24 V2.0
This Page intentionally left as blank

Page 3 of 24 V2.0
Table of Contents
Version Table .................................................................................4
Important Messages......................................................................5
I. Introduction ..............................................................................7
1.1 Features...............................................................................8
1.2 Specifications .......................................................................8
1.3 Sensor cross sensitivity data ................................................9
II. Basic Operation.......................................................................10
2.1 Measuring Screen ..............................................................10
2.1.1 Detailed Screen Description...................................................................................11
2.2 Browsing Screen ................................................................13
2.3 Setting Screen....................................................................15
2.3.1 Modifying Parameters (Settings) ...........................................................................15
2.4 Calibration..........................................................................19
III. Warranty..................................................................................21
User Registration Form...............................................................24

Page 4 of 24 V2.0
Version Table
Date
Version
Comment
May 22, 2015
2.0
User Interface Redesigned
February 1, 2014
1.2
Window 7/8 Compatible Upgrade
May 3, 2012
1.1
Final Release
May 18, 2010
1.0
Initial Release

Page 5 of 24 V2.0
Important Messages
The information in this manual is believed to be accurate to date. However, Hal
Technology assumes no responsibility for any inaccuracies that may be contained in this
manual. In no event will Hal Technology be liable for direct, indirect, special, incidental, or
consequential damages resulting from any defect or omission in this manual, even if
advised of the possibility of such damages. In the interest of continued product
development, Hal Technology reserves the right to make improvements or changes in this
manual and the products it describes at any time, without notice or obligation.
Published in the United States of America
Copyright © 2015 by Hal Technology
All rights reserved. No part of the contents of this manual may be reproduced, transmitted,
stored, or translated into any other language in any form by any means without the written
permission of Hal Technology.
Quality Assurance
•This product has met the product specifications. All the test instruments and
standard materials used for calibration are traceable.
•This certification is for new production only and not valid for used one or ones for
an exhibition purpose.
Commonly used symbols in this manual
Following symbols are used throughout this manual:
The action could lead to harmful damage to the instrument.
Bring you attention about the features of the instrument.

Page 6 of 24 V2.0
Unpacking and Inspection
•Inspect the receiving package and notify the shipper immediately if there appears
to be susceptible damage during shipping.
•Please verify that the enclosed items match with the shipping package list.
This Instrument also contains static sensitive components that may be damaged by improper
handling. The warranty is void for any unauthorized opening of the instrument.
Environmental Requirements
To avoid any accident or damage to the instrument, please avoid using in the following
situations:
•DO NOT expose to combustible, explosive environments.
•DO NOT expose to environments where rust or radioactivity are present.
•DO NOT expose to an environment exceeding the specified limits.
Technical Support and Warrantee
Within a year from the date purchased, the manufacturer will provide free technical support
and software upgrade if applicable. For additional help, please contact
info@haltechnologies.com
It is strongly recommended that the instrument should be calibrated semi-annually or
annually at most. Please contact Hal Technology to schedule your calibration or any
services needed. The HAL-HFX205 can only be serviced at Hal Technology or by Hal
Technology’s authorized and trained professionals.

Page 7 of 24 V2.0
I. Introduction
Formaldehyde (HCHO) is one of the most common, poisonous substances found in daily
life and industry. The HAL-HFX205 handheld Formaldehyde meter is a compact personal
monitor that can provide a rapid indication of hazardous airborne formaldehyde levels at the
touch of a button.
The HAL-HFX205, based on reliable electrochemical sensing technology, features directly
display of the formaldehyde concentration in ppm, and is easy to use. A short, low-
resistance diffusion pathway with a built-in pump enables a rapid reaction time.
Low power design allows long operation time. Exceptional linearity and stability allow easy
and very long intervals between calibration checks. The external digital temperature and
humidity sensors or pressure sensor, if applicable, allows compensation or correction for
accurate measurement. A USB port provides capability of downloading stored data and
possibly continuous, real-time monitoring of the environment remotely.
The HAL-HFX205 Formaldehyde Monitor is designed for use in a wide variety of
applications such asfurniture, floor boards, wall papers, paint,gardening, indoor decoration,
construction, dye stuffs, paper manufacture, hospitals, pharmaceutical, medical, food,
cleaning, synthetic resins, textile treatment, horticulture, and cosmetics.

Page 8 of 24 V2.0
1.1 Features
•Easy to use - minimal operator training required
•Wide measuring range
•Rapid response time
•No warm-up time for sensor
•Direct real time readings allow immediate response to results
•Reliable electrochemical sensor
•Manual and auto save capability
•Auto back light (power saving)
•High-speed USB connectivity
•Simple and easy in-field calibration
•External digital pressure, temperature and humility sensor probe options.
•Temperature compensated reading option
•Live data streaming and TWA/STEL measurement capabilities through USB
•Excess limit warning (user defined)
•Window XP/7/8 compatible
•No less than 6 hours of continuous operation.
1.2 Specifications
•Target Gas: Formaldehyde (HCHO) in air
•Sensor Technology: Electrochemical sensor
•Sampling Method: Pump and pointing sampling
•Range: 0 ~ 10ppm (up to 100ppm available for custom order)
•Response Time: < 30 seconds (T90)
•Resolution: 0.01ppm
•Display Unit: ppm or mg/m3
•Long Term Draft: < ±10% per year (under ideal storage conditions)
•Repeatability: < 2%

Page 9 of 24 V2.0
•Position Sensitivity: None
•Expected Sensor Life: 5 years in non-corrosive environment.
•Display Unit: ppm (4 digit LCD) or mg/m3
•Memory: Up to 500 sets of data
•Interface: USB (Window XP/7/8 compatible)
•Power: Rechargeable Lithium ion battery (3.7V/1200mAh); AC charger 100~
240VAC to 5VDC/1A
•Dimension: 80 (W) 157 (H) 45 (D) mm
•Weight: Less than 240 grams
•Environmental Condition: Operating: 0 ~ 40C, 15% ~ 90%RH; Storage: -20 ~ 50C,
<90%RH
•Standard accessories: AC charger, USB cable, CD with data download software and
user manual
•Optional accessories: Digital pressure, temperature, and humidity sensor probe
1.3 Sensor cross sensitivity data
Chemicals
Cross Sensitivity
Ethanol (C2H6O)
45%
Sulfur Dioxide (SO2)
12%
Phenol (C6H6O)
7%
Carbon Monoxide (CO)
1%
Hydrogen Gas (H2)
0.1%
Chlorine Gas(Cl2)
-3%
Acetone (C3H6O), Ammonia (NH3), CO2, slow H2O vapor have no response;
C2H4, H2S, NO, and NO2 have no data.

Page 10 of 24 V2.0
II. Basic Operation
Six control keypads are used to operate the instrument: , RUN/STOP, ENTER, BACK,
, . Each button controls the following features:
•Power button : While the unit is off, press and hold the power button for
approximately 2 seconds to turn on the instrument. While the unit is on, press and
hold the power button for approximately 2 seconds to turn off the instrument. If the
instrument is not taking measurements it will automatically power off after 5 minutes
of inactivity.
•RUN/STOP: Start or stop measuring/sampling.
• : Move the cursor to select desired screen or item.
•ENTER: Confirm the current selection, enter a parameter, or save the current
sampling value.
•BACK: Change the concentration unit while the unit is measuring or return from the
current selection.
The side of the enclosure includes
•USB Interface: Connect the USB interface to a computer for data downloading or data
logging.
•POWER port: An AC adapter plug-in port: 5 VDC @ 1 A.
•Charge Status LED: LED flashes during charge cycle and becomes steady after the
charge cycle is finished.
2.1 Measuring Screen
The Measure screen, shown in Figure 1, is the main screen of the instrument as it is used
for sampling formaldehyde. The Indicator Display in the upper left corner shows immediate
information about the sample time, sound options, and alarm settings of the instrument. As
Indice