Hardy Barth eCB1-LR Guida rapida

Smartmeter
eCB1-LR
Configuraon instrucons
Configuration instructions eCB1
smartmeter
Version: 1.2.3
1
English

Table of contents
Contact data...............................................................................................................3
General infomaon about the eCB1............................................................................4
Note.................................................................................................................................................4
Meaning of the LED states...............................................................................................................4
Reset funkon..................................................................................................................................4
Setup of direct LAN connecon to the eCB1...............................................................4
Connecng the BUS connecon between wallbox and eCB1......................................7
Configuraon of the eCB1 LR MP+ (metering point)...................................................8
Open the Webinterface...................................................................................................................8
Language und region.......................................................................................................................9
Date und e..................................................................................................................................9
Network se"ngs............................................................................................................................10
Internal...........................................................................................................................................11
Charge connector 1........................................................................................................................12
Finish setup....................................................................................................................................12
Explanaon of the web interface (PV load control)...................................................14
Configuraon of the eCB1 LR PV (PV load control)....................................................15
Language und region.....................................................................................................................15
Date und e................................................................................................................................16
Network se"ngs............................................................................................................................17
House connecon..........................................................................................................................18
Charge connector 1........................................................................................................................20
Setup co pleon...........................................................................................................................22
Fir ware update............................................................................................................................23
I portant se"ngs for operaon...................................................................................................23
Charge-Log.....................................................................................................................................26
Warranty / Guarantee...............................................................................................28
Guarantee specificaons and warranty.........................................................................................28
Notes........................................................................................................................30
Configuration instructions eCB1
smartmeter
Version: 1.2.3
2

Contact data
manufacturer: eCHARGE Hardy Barth GmbH
Leinbergstraße 14
92262 Birgland-Schwend
telephone: +49 9666 188 13 0
telefax: +49 9666 188 13 1
web: www.echarge.de
mail: support@echarge.de
Configuration instructions eCB1
smartmeter
Version: 1.2.3
3

General infomation about the eCB1
Note
To prevent confusion between the different models, please refer to the version of the
device marked on the packeging. The installation and configuration should be carried
out in the specified order.
Meaning of the LED states
Status-LED
•
permanent green The eCB1 is ready for operation.
•
Slowly flashing in green The device starts.
•
Quickly flashing in green A firmware update is running.
•
glowing or flashing in red or An error occured.
orange
Network-LED
•
Off no connection
•
permanent green connection active
•
green flashing network activity
Bus-LED
•
Off device is not configured
•
green connection is ok
•
orange no device detected
•
red BUS error
Reset funktion
You can reset the eCB1 to network settings or simply restart the device by pressing the
reset button. The time period of pressure applied is important.
Reset to factory settings
With a pointy ob ect, press the reset button for 4 to 10 seconds.
Restart the eCB1
To restart, use a pointy ob ect to press the reset button for 1 to 3 seconds.
Setup of direct LAN connection to the eCB1
Configuration instructions eCB1
smartmeter
Version 1.2.3
4

Step 1: Install the eCB1 and connect it to the power supply.
Step 2: Connect the eCB1 to your network, a PC or laptop using a LAN cable see
diagram).
Please note: Make sure that only one unconfigured eCB1 is connected in your network to
avoid name collisions.
1. Start your browser
2. Type in the following URL „http://ecb1.local“ see image below).
→ The user interface of the eCB1 opens.
If the user interface does not open, please check the following points:
1. Name resolution does not work
Configuration instructions eCB1
smartmeter
Version: 1.2.3
5
Connect the eCB1 to your
network using a LAN cable
and insert it into the LAN
port of the eCB1.
Connect your PC/laptop with
your network/router by
inserting the LAN cable into
the LAN port.

Access the user interface using the current IP address of the eCB1.
„(http://<IP>/)“
To do this, ca up the router´s user interface and read the IP address of the eCB1 (see
manua of your router).
If you have Windows XP/7/8: insta App e Bonjour® . You can find the donw oad ink on
www.app e.com. Then enter the URL again.
Note: App e Bonjour® is a so inc uded in App e iTunes®.
A ternative y contact the network administrator.
2. The status LED does not glow
If the status LED of the eCB1 does not g ow, it means that
the smartmeter is not provided with any power.
P ease make sure that at east one of the phase conductos
L1 and the neutra conductor N are connected to the eCB1.
3. The status LED glows or blinks red
If the status LED g ows or b inks red, an error has occured.
P ease restart the eCB1 by pressing the reset button
with a pointy objet for about to 3
seconds.
4. The Network-LED does not glow
If the network-LED does not g ow, the network cab e is not proper y/correct y connected to
the network port. P ease make sure that you have inserted both ends of the cab e proper y
and correct y.
5. eCB could not be found in the network
In this case the eCB1 is not ocated in the same oca network. P ease connect the
eCB1 with the same Router/Switch as the one of your PC’s/ aptop’s.
If that does not so ve your prob em, p ease reset the eCB1 to its factory settings by
pressing the reset button with a pointy object for about 4 to 0 seconds.
Configuration instructions eCB
smartmeter
Version: 1.2.3
6

Connecting the BUS-connection between wallbox
and eCB1
Image 1: shows the BUS-clamps of the cPµ1.
Image 2: shows the BUS-clamps of the eCB1.
(Please note the green marks in Image )
hese have to be connected as follows:
- Plug the brown wire (second slot on the eCB1) in
„1“ (shown in Image 1).
- Plug the black wire (third slot on the eCB1) in
„2“.
- Last step you plug the blue wire (first slot on the
eCB1) in „3“.
Configuration instructions eCB1
smartmeter
Version: 1.2.3
7
1
2
1

Configuration of the eCB1 LR MP+ (metering
point)
Open the Webinterface
Open the Webinterface of the eCB1 MP+ (metering point at the house connection) by
entering its IP address in your webbrowser
Prior to that, it has to be integrated into the network of the house Then through the
interface of the router, you can find the IP address of all eCB1, including this one
If therer is no other configured eCB1 in your Network you can contact the eCB1 MP+ with
http://ecb1 local for first configuration
If the Domane Name System does not work you can find the IP adress through the
Webinterface of your router
The following page should open up:
Please click “proceed” to get to the following section:
Configuration instructions eCB1
smartmeter
Version: 1.2.3
8

Language und region
Here you can set:
–the language
–the country in which you are installing the charging station and
–the time zone
Date und time
Click “proceed” to get the following screen:
Here you can set the time and date manually or automatically.
Configuration instructions eCB1
smartmeter
Version: 1.2.3
9

Manual setting
Click on the date button and select the desired date from the calendar. Then click the
time button and enter the current time.
Please separate the hours, minutes and seconds with colons.
To complete the settings, press “Set time” and the settings will be saved.
Automatic setting
In this case “Date” and “Time” do not need an entries.
There are pre-set internet pages in section “NTP Server 1” and “NTP Server 2”. These will
connect ou automaticall with a time server.
Click on “Set time by ntp” to save our settings.
If ou want to connect with a different, or our own time server, please enter the internet
address manuall .
B clicking “automatic synchronise at boot”, the time will be s nchronised automaticall
after ever outage (power, network, etc.).
After completion of the time and date settings, click on “proceed” to get to the next
section.
Network settings
If ou choose “DHCP” as protocol:
Your DHCP-Server (e. g. router) will do
further settings automaticall and fill the
remaining blank spaces.
There are no other settings to be made in
the section except selecting a hostname.
Please select a distinct host name.
The device should respond to the given
hostnamen (givenname.local). Upon deliver
the hostname given is „ecb1 local“.
Configuration instructions eCB1
smartmeter
Version: 1.2.3
10
Altri manuali per eCB1-LR
1
Indice
Altri manuali Hardy Barth Strumento di misura