HBM PAD4001A Manuale utente

Operating Manual | Bedienungsanleitung |
Manuel d'emploi
English Deutsch Français
PAD4001A/4003A

Hottinger Baldwin Messtechnik GmbH
Im Tiefen See 45
D-64239 Darmstadt
Tel. +49 6151 803-0
Fax +49 6151 803-9100
www.hbm.com
Mat.: 7-1001.4238
DVS: A4238-1.0 HBM: public
10.2015
EHottinger Baldwin Messtechnik GmbH.
Subject to modifications.
All product descriptions are for general information only.
They are not to be understood as a guarantee of quality or
durability.
Änderungen vorbehalten.
Alle Angaben beschreiben unsere Produkte in allgemeiner
Form. Sie stellen keine Beschaffenheits- oder Haltbarkeits
garantie dar.
Sous réserve de modifications.
Les caractéristiques indiquées ne décrivent nos produits
que sous une forme générale. Elles n'impliquent aucune
garantie de qualité ou de durablilité.

Operating Manual | Bedienungsanleitung |
Manuel d'emploi
English Deutsch Français
PAD4001A/4003A
Digital transducer electronics

2A4238-1.0 HBM: public PAD4001A/4003A
English
1 Safety instructions 3........................................
2 Markings used 7............................................
2.1 Symbols on the device 7......................................
2.2 The markings used in this document 7..........................
3 Structure and mode of operation 9...........................
3.1 Structure of the electronics 10..................................
3.2 Signal conditioning 11.........................................
3.3 Adaptive interference suppression 12............................
3.4 Inputs and outputs 13.........................................
3.4.1 Trigger function 13............................................
3.4.2 Filling and dosing 14..........................................
3.4.3 Limit value function 14.........................................
3.4.4 Extreme value functions 14....................................
4 Conditions on site 15........................................
5 Mechanical installation 16....................................
5.1 Important precautions during installation 16......................
5.2 Dimensions 17...............................................
6 Electrical connection 18......................................
6.1 Cable laying 18...............................................
6.2 Pin assignment 18............................................
6.3 Supply voltage 21.............................................
7 Interfaces 23................................................
7.1 RS‐485 4‐wire interfaces (UART) 23............................
7.2 CANopen interface 25.........................................
8 Operation via software 27....................................
9 Waste disposal and environmental protection 27..............

Safety instructions
PAD4001A/4003A A4238-1.0 HBM: public 3
1 Safety instructions
Appropriate use
PAD digital transducer electronics are to be used exclus
ively for measurement tasks and directly related control
tasks within the application limits detailed in the specifica
tions. Any other use is not appropriate.
Any person instructed to carry out installation, commis
sioning or operation of the device must have read and
understood the Operating Manual and in particular the
technical safety instructions.
In the interests of safety, the device should only be oper
ated by qualified personnel and as described in the Oper
ating Manual. It is also essential to comply with the legal
and safety requirements for the application concerned
during use. The same applies to the use of accessories.
PAD is not intended for use as a safety component.
Please also refer to the "Additional safety precautions"
section. Proper and safe operation requires proper trans
portation, correct storage, siting and mounting, and care
ful operation.
Operating conditions
SPlease observe the allowed maximum values stated
in the specifications for:
- Max. supply voltage
- Max. voltage for inputs and outputs
- Max current of outputs
- Temperature limits
SMake sure that the max. current for plugs and sockets
is adhered to in bus mode.

Safety instructions
4A4238-1.0 HBM: public PAD4001A/4003A
SThe device must not be modified from the design or
safety engineering point of view except with our ex
press agreement. In particular, any repair or soldering
work on motherboards (exchanging components) is
prohibited.
SThe device is delivered from the factory with a fixed
hardware and software configuration. Changes can
only be made within the possibilities listed in the cor
responding documentation.
SThe device is maintenance free.
SPlease note the following points when cleaning the
housing:
- Disconnect the device from all current and voltage
supplies before cleaning it.
- Clean the housing with a soft, slightly damp cloth.
Never use solvent, as this could damage the label
or the housing.
- When cleaning, ensure that no liquid gets into the
device or connections.
SIn accordance with national and local environmental
protection and material recovery and recycling regula
tions, old equipment that can no longer be used must
be disposed of separately and not with normal house
hold garbage, see Chapter9 on page27.
Qualified personnel
Qualified persons means persons entrusted with the in
stallation, fitting, commissioning and operation of the
product who possess the appropriate qualifications for
their function.
This includes people who meet at least one of the three
following requirements:

Safety instructions
PAD4001A/4003A A4238-1.0 HBM: public 5
SKnowledge of the safety concepts of measurement
and automation technology is a requirement and as
project personnel, they must be familiar with these
concepts.
SAs measurement or automation plant operating per
sonnel, they been instructed how to handle the ma
chinery. They are familiar with the operation of the
equipment and technologies described in this docu
mentation.
SAs commissioning engineers or service engineers,
they have successfully completed the training to qual
ify them to repair the automation systems. They are
also authorized to activate, ground and label circuits
and equipment in accordance with safety engineering
standards.
Working safely
SThe device must not be directly connected to the
power supply system. The supply voltage must be
between 12 and 30VDC.
SError messages should only be acknowledged once
the cause of the error is removed and no further
danger exists.
SAutomation equipment and devices must be designed
in such a way that adequate protection or locking
against unintentional actuation is provided (e.g. ac
cess checks, password protection, etc.).
SFor those devices operating in networks, safety pre
cautions must be taken both in terms of hardware and
software, so that a line break or other interruptions to
signal transmission do not cause undefined states or
loss of data in the automation device.

Safety instructions
6A4238-1.0 HBM: public PAD4001A/4003A
SAfter making settings and carrying out activities that
are password-protected, ensure that any controls that
may be connected remain in a safe condition until the
switching performance of the device has been tested.
Additional safety precautions
Additional safety precautions to meet the requirements of
the relevant national and local accident prevention regu
lations must be taken in plants where malfunctions could
cause major damage, loss of data or even personal in
jury.
The scope of supply and performance of the device cov
ers only a small area of measurement technology. Before
starting up the device in a system, a project planning and
risk analysis must first be implemented, taking into ac
count all the safety aspects of measurement and auto
mation technology so that residual risks are minimized.
This particularly concerns personal and machine protec
tion. In the event of a fault, the relevant precautions must
establish safe operating conditions.
General dangers of failing to follow the safety
instructions
The device is state of the art and failsafe. The device
may give rise to residual dangers if it is inappropriately
installed or operated.

Markings used
PAD4001A/4003A A4238-1.0 HBM: public 7
2 Markings used
2.1 Symbols on the device
CE mark
The CE mark enables the manufacturer to guarantee that
the product complies with the requirements of the relev
ant EC directives (the Declaration of Conformity can be
found on the HBM website (www.hbm.com) under HBM
doc).
Statutory waste disposal mark
In accordance with national and local environmental pro
tection and material recovery and recycling regulations,
old devices that can no longer be used must be disposed
of separately and not with normal household garbage.
Also see Chapter9 on page27.
2.2 The markings used in this document
Important instructions for your safety are specifically
identified. It is essential to follow these instructions in or
der to prevent accidents and damage to property.
Symbol Significance
Notice This marking draws your attention to a situation in
which failure to comply with safety requirements can
lead to damage to property.
Important
This marking draws your attention to important in
formation about the product or about handling the
product.

Markings used
8A4238-1.0 HBM: public PAD4001A/4003A
SignificanceSymbol
Information
This marking draws your attention to information
about the product or about handling the product.
Emphasis
See …
Italics are used to emphasize and highlight text and
identify references to sections, diagrams, or external
documents and files.
Altri manuali per PAD4001A
1
Questo manuale è adatto per i seguenti modelli
1
Indice
Lingue:
Altri manuali HBM Amplificatore

HBM
HBM ME30 Manuale utente

HBM
HBM CMD600 Istruzioni per l'installazione

HBM
HBM PACEline CMD Series Manuale utente

HBM
HBM ME50S6 Manuale utente

HBM
HBM MVD2510 Manuale utente

HBM
HBM PMX Istruzioni per l'installazione

HBM
HBM MVD2555 Manuale utente

HBM
HBM MX840B Manuale utente

HBM
HBM VKIA405 Manuale utente

HBM
HBM ME30 Manuale utente































