Imation Matchprint Professional Server Manuale

Hardware Installation and Startup Guide
Imation Matchprint™ Professional Server
Version 2.0
Contents
PRODUCT SAFETY AND COMPLIANCE..............................................................................2
SPECIFICATIONS.......................................................................................................................4
UNPACKING................................................................................................................................5
CART ASSEMBLY......................................................................................................................6
SERVER INSTALLATION AND CABLING.............................................................................7
PRINTER SETUP......................................................................................................................11
PRINTER CALIBRATION ........................................................................................................12
SPECTROCAM TIPS AND TROUBLESHOOTING.............................................................18
SYSTEM TROUBLESHOOTING............................................................................................19
HOW TO REPLACE THE BATTERY.....................................................................................20

Hardware Installation and Startup Procedure
252-0001-4320-7, Rev. B Imation Corp. 2001
Product Safety and Compliance
Warning
Do not modify or use any AC power cord other than the one included with shipping.
In some cases, the supplied power cord may not be compatible with the AC wall outlet in your
region. If this is true, you must obtain a suitable power cord that meets the following criteria:
•The cord must be rated for use at the AC voltage available, with a current rating that is at least
125% of the current rating of the product.
•The AC plug end must be terminated in a grounding-type male plug designed for use in your
region. The plug ends must be labeled or marked to indicate they have been certified by an
agency acceptable in your region.
•The connector at the product end must be an IEC 320, sheet C13, female connector (or the
equivalent EN 60 320 connector.)
•The cord must be less than 14.8 feet (4.5 meters) long and, for use in Europe, be created with
<HAR> (harmonized) or VDE certified cordage.
Warning
1. The user must never remove chassis covers. Some system circuitry retains voltage even when
the system is turned off. Only qualified service technicians should remove chassis covers.
2. There are no user-serviceable components in the Imation server. Refer all systemrepair to a
qualifiedservicetechnician.
Warning
The power supply voltage standby circuit is active when the computer is turned off. Ensure that the
computer is disconnected from its power source and from all telecommunication links, networks, or
modem lines whenever the chassis cover is removed. Do not operate the computer with the cover
removed. Only qualified service technicians should remove chassis covers if repair or component
replacement is required.
Warning
Danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent
type recommended by the equipment manufacturer. Discard used batteries according to
manufacturer’s instructions.

Hardware Installation and Startup Procedure
Imation Corp. 2001 52-0001-4320-7, Rev. B 3
Agency Approvals
U.S. FCC Class B
UL 1950 standard testing
Canada Canadian EMI Class A
CSA 950
Europe CISPR 22 Class B
CE Mark
EN 60950 LUD
The radiated and conducted emissions are per EN 55022 class B limits.
The radiated and conducted immunity are per EN 55024 class B limits.
The ImationMatchprint™ Professional Server fulfills the following European Directives and their current
amendments:
73/23/EEC, Low Voltage Directive (LVD) and
89/336 ECC Electromagnetic Compatibility Directive.
Dieses Produkt "IMPS" erfuellt dieAnforderungen der folgenden europaeischen Richtlinien und deren
derzeit gueltigen Ergaenzungen:
73/23/EWG Niederspannungsrichtlinie
89/336/EWG Richtlinie ueber elektromagnetische Vertraeglichkeit
Radio Frequency Interference Notice (USA)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and the receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to
operate the equipment. The customer is responsible for ensuring compliance of the modified product. Only
peripherals (computer input/output devices, terminals, printers, etc.) that comply with FCC class B limits may be
attached to this computer product. Operation with non-compliant peripherals is likely to result in interference to radio
and TV reception.
All cables used to connect peripherals must be shielded and grounded. Operation with cables, connected to
peripherals, that are not shielded and grounded may result in interference to radio and TV reception.
If a Class A device is installed within this system, then the system is considered a Class A system. In this
configuration, operation of this equipment in a residential area is likely to cause harmful interference.
Radio Frequency Interference Notice (CDN)
This Class B digital apparatus complies with Canadian ICES-003.

Hardware Installation and Startup Procedure
452-0001-4320-7, Rev. B Imation Corp. 2001
Specifications
The Imation Matchprint™ Professional Server comes in three boxes.
Shipping Carton Specifications
IMN part number Description Dimensions
L x W x H Weight
Lbs.
74-0401-9321-6 Imation Matchprint™
Professional Server 30” x 30” x 20” 50
74-0401-9539-3 Cart 32.75” x 29.5” x 37.75” 67
66-0000-1958-9 Monitor 19.25" x 9.75" x 20" 16
Equipment Specifications
Server Dimensions:
Height: 22” (558 mm)
Length: 19.5” (495 mm)
Width: 12” (305 mm)
Weight: 34 lbs. (16.5 kg)
Keyboard Dimensions:
Width: 18” (457 mm)
Length: 7” (178 mm)
Height: 1.75” (44.5 mm)
Weight: 1 lb. (0.45 kg)
Server Specifications:
Voltage: 115 – 230 VAC
Current: 10/5 Amps.
Frequency: 50/60 Hertz
Video Monitor – LCD
Width: 15.5” (394 mm)
Height: 16” (406 mm)
Length: 7” (178 mm)
Weight: 12 lbs. (5.45 kg)
Environment:
Temperature 68°- 90°F (16°- 32°C) Video Monitor Specifications:
Voltage: 100-240 VAC
Current: 1 Amp
Frequency: 50/60 Hertz
Monitor box not
shown.
Server and cables Cart (optional) Monitor

Hardware Installation and Startup Procedure
Imation Corp. 2001 52-0001-4320-7, Rev. B 5
Unpacking
Unpack the Imation Matchprint™ Professional Server. The following items are
included in your shipping box:
•Imation MatchprintProfessional Server
•Monitor
•Keyboard
•Mouse
•Print cable
•Scan cable
•Power cable
•Cart (not shown, optional)
Print and Scan
cables are
labeled.

Hardware Installation and Startup Procedure
652-0001-4320-7, Rev. B Imation Corp. 2001
Cart Assembly
Assemble the carttable-top, shelf and wheels as shown in the following graphic:

Hardware Installation and Startup Procedure
Imation Corp. 2001 52-0001-4320-7, Rev. B 7
Server Installation and Cabling
1. Position the system as shown in the following graphic.
The monitor and Imation Matchprint™ Professional Server should be located within
10 feet of the DC12 copier. The CPU should be placed in a location that provides
sufficient airflow clearance. The monitor should be positioned on a solid table or cart.
2. Connect the system cables to the back of the Imation Matchprint™ Professional
Server as follows:
üNote
All external peripheral cables are designed so the connector can only be
inserted in one orientation. Check the orientation of the connector if the
cable does not connect easily. Do not use excessive force to connect a
cable.
a) Connect the monitor cable to the location shown in the graphic. The cable with
the blue connector is the monitor cable. (Do notconnect the blue end of the
monitor cable to the blue connector location. Use the location shown in the
graphic on page 6.)
b) Connect the keyboard cable to the purple connector on the Imation server. The
keyboard cable has a corresponding purple connector.
c) Connect the mouse cable to the corresponding connector on the Imation server.
d) Connect the scan cable latched-end to the Imation server and the thumbscrew-
end to the Xerox DocuColor 12™ copier. The scan cable is identified by a label
on the connector.
e) Connect the print cable latched-end to the Imation server and the thumbscrew-
end to the Xerox DocuColor 12™ copier. The print cable is identified by a label
on the connector.

Hardware Installation and Startup Procedure
852-0001-4320-7, Rev. B Imation Corp. 2001
f) Connect the power cable to the Imation server and AC power outlet.
g) If your Xerox DocuColor 12 LP requires aSpectrocam external calibration
device, connect theSpectrocam to the COM 1 port.
Warning
Do not modify or use any AC power cord other than the one included with shipping.
* The Xerox DocuColor 12™ copier thumbscrew-end connections for both the print
and scan cables are shown in the following graphic.
a) Monitor cable
c) Mouse cable
b) Keyboard cable
(purple)
d) Scan cable*
e) Print cable*
f) Power cable
Print
cable Scan
cable
Do not use this
connection for the
monitor. This
connection will not
support an LCD
screen.
g) COM 1
Spectrocam
connection

Hardware Installation and Startup Procedure
Imation Corp. 2001 52-0001-4320-7, Rev. B 9
3. Power up the system by pressing the power switch located behind the front cover as
shown in the following graphic.
The Imation Matchprint™ Professional Server software comes preloaded.
System power up takes about 30 seconds. A screen prompt appears saying: “Please
select operating system to start.” Leave the default selection as Imation
Matchprint™ Professional Server. The system will automatically boot after 5
seconds.
4. When the following system prompt appears, press Ctrl + Alt + Delete to log on.
5. Enter log on information as follows:
User name: Administrator
Password: (No password is required.)
Domain: (No domain entry is required. Server is not connected to a network.)
Power on
button

Hardware Installation and Startup Procedure
10 52-0001-4320-7, Rev. B Imation Corp. 2001
6. After the log on information is entered, click OK.
7. To launch the program, double-click on the Imation Matchprint™ Professional
Server icon located on the desktop.
Indice