iNels Connection server Manuale utente

Version02‐039/2011Rev.:091013
Connection Server Installation Manual

Verze02‐039/2011Rev.:091013 Stránka2z31
Connection Server Installation Manual
Contents
Contents.............................................................................................................................................................................. 2
1.Getting started ......................................................................................................................................................... 3
1.1.Putting Connection Server in run................................................................................................................. 3
1.2.Basic settings................................................................................................................................................ 4
1.2.1.Change of password................................................................................................................................ 4
1.2.2.System restart and shutdown.................................................................................................................. 4
1.2.3.Setting static Connection Server IP address ........................................................................................... 5
2.Configuration in iMM Control Center..................................................................................................................... 6
2.1.iMM CC setting............................................................................................................................................ 6
2.1.1.Bookmark Server.................................................................................................................................... 6
2.1.2.Bookmark Configuration........................................................................................................................ 6
2.1.3.Bookmark A/C........................................................................................................................................ 8
2.1.4.Bookmark Rooms................................................................................................................................... 9
2.1.5.Bookmark Cameras .............................................................................................................................. 10
2.1.6.Calling between individual devices and sound..................................................................................... 11
2.1.7.Phone settings....................................................................................................................................... 12
2.1.8.IP sound ............................................................................................................................................... 14
2.1.9.Bookmark Energy................................................................................................................................. 15
2.1.10.Bookmark Audit.............................................................................................................................. 19
2.2.Heating....................................................................................................................................................... 20
2.3.Connection of Miele household appliances................................................................................................ 21
3.Supplements .......................................................................................................................................................... 23
3.1.Export of configuration file to iMM........................................................................................................... 23
3.2.Third parties' devices ................................................................................................................................ 24
3.2.1.Supported Miele appliances.................................................................................................................. 24
3.2.2.Air conditioning unit CoolMaster......................................................................................................... 26
3.2.3.Connection of air conditioning units .................................................................................................... 29

Verze02‐039/2011Rev.:091013 Stránka3z31
Connection Server Installation Manual
1. Getting started
Commands are given in purple, e.g.: sudo reboot
Paths and links are given in red: imm/Pictures
Notices are given in orange: No characters display when writing a password in
terminal
Tips and tricks are given in green: You do not want to run configuration via iMM CC at
every server separately; as long as they are more, iMM CC can be enabled from any
PC connected to local network…
Commands are in italic
Important configuration commands in Linux:
Ifconfig - finding IP address of station/server, similar to IPCONFIG in Windows
mount – command for connection of certain device CD-ROM, network drive, etc.)
umount - command for disconnection of certain device
1.1. Putting Connection Server in run
a) Once you unpack Connection server, let the device stabilize at room temperature.
b) Insert attached SD card in the slot.
c) Connect the cabling (do not connect the supply yet):
Display HDMI device
LAN cable for ethernet port!
Keyboard to USB port.
d) After connecting the power supply (adapter with micro USB connector), Connection
Server will start automatically.
e) When starting the system you can watch opening of individual services on the
screen. Some services do not open, and display FAILD in red; in majority of cases it
is not a problem; and has no influence whatsoever on the run of Connection Server.
f) When start of services is completed, only one line requiring login name will appear on
the screen.
Alarmpi login: imm
Password: imm123
No characters display when writing a password in terminal

Verze02‐039/2011Rev.:091013 Stránka4z31
Connection Server Installation Manual
g) To find IP address after signup use command ifconfig
h) Further settings are performed via web interface iMM Control Center. And display
device or keyboard need not be connected for the rest of time. Power supply, SD card
with system and application and connection to network is sufficient to run Connection
Server.
1.2. Basic settings
Setting in this chapter need not be carried out; it serves for potential problem solution and
general assistance in the Linux system orientation. Majority of these settings is done already in
the production but one should get familiarized with them and go back to them if a problem
occurs.
1.2.1. Change of password
a) Enter sudo passwd and confirm by Enter.
b) You will be asked to enter the original password (default is “imm123“), and confirm by
Enter.
c) Then enter a new password, confirm by Enter; repeat the new password and confirm by
Enter.
No characters display when writing a password in terminal.
1.2.2. System restart and shutdown
If you already know the IP address of Connection Server, the best way to restart or switch off is via
iMMCC or remote access. By means of SSH e.g. in Putty software (free downloadable on internet).
Sign up with the same data:
Login: imm
Password: imm123
Command for restart: sudo reboot
Command for switching off: sudo shutdown
If you begin with sudo command, Linux should always ask to enter the password.

Verze02‐039/2011Rev.:091013 Stránka5z31
Connection Server Installation Manual
1.2.3. Setting static Connection Server IP address
In the System bookmark, you can reset parameters of network setting or restart, or use the
“Shutdown” button to turn off Connection Server completely.
IP address is usually set static to avoid its change in time.
Network interface setting
Button for complete shutdown
Restart button
IP address in sub-network
which iMM server is
connected to
Mask setting Default
gate a
DNS
server

Verze02‐039/2011Rev.:091013 Stránka6z31
Connection Server Installation Manual
2. Configuration in iMM Control Center
IMM Control Center (the “iMMCC” hereinafter) is web interface serving for Connection
Server setting. iMM CC is activated upon entering an address in your internet browser.
2.1.iMM CC setting
2.1.1.Bookmark Server
This bookmark contains control to virtual servers necessary for communication with CU,
applications and devices of third parties. Within diagnostics, the state of individual virtual
servers can be revealed (button “Status”), suspend their run (button "Stop"), or turn them on
(button "Start"). Servers are turned on automatically when Connection Server starts up.
Virtual server communicating
with central unit
Virtual server
communicating with Miele
Virtual server
communicating with iHC
applications

Verze02‐039/2011Rev.:091013 Stránka7z31
Connection Server Installation Manual
2.1.2.Bookmark Configuration
On this bookmark you can set IP address of central unit, IP address of server; in this case
local address of Connection Server by entering 127.0.0.1!
There you can also upload export.pub exported from central unit
Central unit IP
address
iMMserverIPadd
r
ess
Application licence
Update settings
Find file “export.pub“
Upload file “export.pub“
There are units,
events and
variables from
iNELS that are
imported to iMM
Save changes performed in the
extract from file export.pub

Verze02‐039/2011Rev.:091013 Stránka8z31
Connection Server Installation Manual
2.1.3.Bookmark A/C
Serves for definition of air conditioning units and their control by means of iHC application.
Supported communication card for air conditioning units is LG je PI485. See chapter Wiring of
Air Conditioning Units for connection.
Optional name
of inner unit Selection of communication interface
IP address of
RS485/Ethernet
t
t
Communication port of
RS485/Ethernet converter
Serves for entering
central air
conditioning address
Creates defined air conditioning unit
Seznam již definovaných
klimatizačních jednotek
Central air conditionin
g
unit
Selection of UID
same as you
selected for air
IP address of
RS232 converter
Unit name
(optional)
List of already defined air
conditioning units

Verze02‐039/2011Rev.:091013 Stránka9z31
Connection Server Installation Manual
2.1.4.Bookmark Rooms
Serves for configuration of file rooms.cfg which uploads iHC applications. Read more in the manual
for iHC application.
Name of new room
Control of room will be
protected by password
Editin
g
items in room
Removal of room
Password setting and change
for access to room

Verze02‐039/2011Rev.:091013 Stránka10z31
Connection Server Installation Manual
2.1.5.Bookmark Cameras
Serves for defining IP cameras you want to check by means of Application.
HTTP and RTSP ports are only entered if your IP cameras are configured for access from external
network.
All cameras by Axis manufacturer with V2 and V3 protocol are supported, further we support the below
listed types of cameras:
AirLive-WL2600, AirLive AirCam OD-600HD, AirLive AirCam OD-325HD, Planet ICA-M220, ACTi-
ACM, and the following types by company Vivotek: FD-8134, FD-7132, PZ-7132.
Select any camera name
Camera IP address
User name for access to camera
Access password for camera
Camera type
List of already defined cameras
RTSP port
HTTP port
Altri manuali per Connection server
1
Indice
Altri manuali iNels Server