INFICON Table of Contents
BM1000-Operating-Instructions-jiqb10en1-06-(1901) iii
Table of Contents
1 About these instructions ...................................................................................................................................4
1.1 Other associated documents ....................................................................................................................4
1.2 Target groups ...........................................................................................................................................4
2 Safety ...............................................................................................................................................................5
2.1 Owner requirements .................................................................................................................................5
2.2 Operator requirements..............................................................................................................................5
2.3 Warnings...................................................................................................................................................5
3 Shipment, Transport, Storage ..........................................................................................................................7
4 Description........................................................................................................................................................8
4.1 Construction of the bus module ................................................................................................................8
4.2 Function ....................................................................................................................................................8
4.3 Technical data ..........................................................................................................................................9
5 Installation and removal..................................................................................................................................10
5.1 Mount the bus module and the DIN-TS35 top hat rail ............................................................................10
5.2 Establish connections .............................................................................................................................10
5.3 Remove the bus module from the DIN-TS35 top hat rail........................................................................11
6 Decommissioning the measuring instrument..................................................................................................12
6.1 Disposing of the device...........................................................................................................................12
6.2 Sending in the device .............................................................................................................................12
7 Appendix.........................................................................................................................................................14
7.1 CE Declaration of Conformity .................................................................................................................14
7.2 RoHS ......................................................................................................................................................15

1 | About these instructions INFICON
4 / 20 BM1000-Operating-Instructions-jiqb10en1-06-(1901)
1 About these instructions
1.1 Other associated documents
• Operating instructions of the connected leak detector
• Protocol Descriptions, Document No. jira54
1.2 Target groups
This instruction manual is aimed at the operator of the device and at technically
qualified specialists, with experience in the field of leak testing technology.

INFICON Safety | 2
BM1000-Operating-Instructions-jiqb10en1-06-(1901) 5 / 20
2 Safety
2.1 Owner requirements
Safety conscious
operation
Operate and install the device only in technically perfect working order and as
specified, in a safety-conscious and hazard-conscious manner and in compliance with
these instructions.
► Fulfill and ensure compliance with the following regulations:
- Intended use
Universally valid safety and accident prevention regulations
- International, national and local standards and guidelines
- Additional device-related provisions and regulations
► Use only original parts or parts approved by the manufacturer.
► Keep this manual available at the operating site.
Personnel
qualifications
► All work must be performed only by technically qualified specialists who have been
trained on the device.
► Allow personnel in training to work on the device only under the supervision of
technically qualified specialists.
► Make sure that the authorized personnel have read and understood these
instructions and all other applicable documents (refer to "Other associated
documents"), especially the information on safety, maintenance and repairs, before
starting work.
► Define responsibilities, authorizations and supervision of personnel.
2.2 Operator requirements
► Read, observe and follow the information in these instructions and the working
instructions created by the owner, especially the safety instructions and warnings.
2.3 Warnings
DANGER
Imminent hazard resulting in death or serious injuries

2 | Safety INFICON
6 / 20 BM1000-Operating-Instructions-jiqb10en1-06-(1901)
WARNING
Hazardous situation resulting in potential death or serious injuries
CAUTION
Hazardous situation resulting in minor injuries
NOTICE
Hazardous situation resulting in damage to property or the environment

INFICON Shipment, Transport, Storage | 3
BM1000-Operating-Instructions-jiqb10en1-06-(1901) 7 / 20
3 Shipment, Transport, Storage
Scope of delivery Item Quantity
Bus module 1
Operating instructions 1
► Please check the scope of delivery of the product for completeness after receipt.
Transport
NOTICE
Damage due to unsuitable packaging material
Transport in unsuitable packaging material can damage the device.
Transport the device only in the original packaging.
Keep the original packaging.
Storage ► Store the device taking into consideration the technical data, refer to Chapter 4.3,
page 9.

4 | Description INFICON
8 / 20 BM1000-Operating-Instructions-jiqb10en1-06-(1901)
4 Description
4.1 Construction of the bus module
Fig.1:
Front view
1 Connection for the cable to the
leak detector (LD)
2 Status LED Lights up green when
the operating voltage is applied to
the bus module.
4.2 Function
The bus module is a device interface between e.g. the MSB box of the mass
spectrometer module LDS3000 and an external controller. The bus module BM1000 is
available from INFICON in the following versions:
• 560-315 BM1000 PROFIBUS
• 560-316 BM1000 PROFINET
• 560-317 BM1000 DeviceNet
• 560-318 BM1000 EtherNet/IP

INFICON Description | 4
BM1000-Operating-Instructions-jiqb10en1-06-(1901) 9 / 20
4.3 Technical data
Dimensions (L×W×H) 107.6 mm x 89.7 mm x 76.6 mm
Weight 0.5 kg (1.74 lb.)
Table1:
Mechanical data
Protection class IP20
Nominal voltage 24 V
Nominal frequency DC voltage
Nominal power <3 VA
Table2:
Electrical data
Max. height above sea level 2000 m
Max. relative humidity above 40 °C 50%
Max. relative humidity from 31 °C to 40
°C
80% to 50% (decreasing linearly)
Max. humidity up to 31 °C 80%
Max. storage temperature -20 °C … 60 °C
Permissible ambient temperature (during
operation)
5 °C … 50 °C
Pollution degree II
Table3:
Ambient conditions

5 | Installation and removal INFICON
10 / 20 BM1000-Operating-Instructions-jiqb10en1-06-(1901)
5 Installation and removal
NOTICE
Install the bus module so that you can always easily disconnect the cable to the leak
detector.
5.1 Mount the bus module and the DIN-TS35 top
hat rail
Fig.2:
Mounting of bus module
1. Hook device on top hat rail at bottom.
2. Press device onto top hat rail at top.
5.2 Establish connections
Connect the bus module with the leak detector
The bus module communicates via data cable with the leak detector and is supplied
with voltage by the data cable.
üThe device must be supplied with a circuit that meets the requirements of "Energy-
limited circuits" of DIN EN 61010-1 (VDE 0411-1).
üINFICON data cable
1
Connect the bus module (connection LD) via the data cable with the leak
detector.
Altri manuali per BM1000 Series
1
Questo manuale è adatto per i seguenti modelli
8
Indice
Altri manuali Inficon Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente