InWin IW-RS216-07 Manuale utente

2U NVMe Hybrid Storage Server User Manual
IW-RS216-07

2
PREFACE
Thank you for choosing the InWin IW-RS216-07 storage server. This manual is written for system technicians who
are responsible for installation, managing and repairing this server chassis. This document provides an overview of
all the features of the chassis, a list of accessories or other components you may need to finish the installation and
instructions on adding and removing components in the InWin IW-RS216-07. For the latest version of this manual, you
may visit InWin’s server website.
SAFETY INFORMATION
To ensure a safe and smooth operation of your InWin IW-RS216-07, it is essential that you choose an appropriate
location for the system, provide an appropriate operating environment and supply an adequate amount of power for
all components of the system. As you plan for installation, follow the guidelines below to ensure that the system and its
environment are safely and appropriately positioned for efficient operation and service. Your system should be installed
and serviced only by a qualified technician.
Environment Selection:
The system is designed to operate in a typical office environment:
• The location should be clean, dry and free of airborne particles.
• It should be placed in a well-ventilated room, and away from sources of heat including direct sunlight and radiators.
• It should be kept away from sources of vibration or physical shock.
• The space should be accommodated with a properly grounded wall outlet, and with sufficient space to access the
power supply cords.
• The operating environment temperature should be around 0°C to 40°C (32°F to 104°F).
Heed Safety Instructions:
Before working with InWin IPC/storage/SMB server products, we strongly recommend you use this guide as a reference
and follow the safety instructions. The instructions in this manual will help you ensure and maintain compliance with
existing product certifications and approvals. Follow the described, regulated components mentioned in this manual.
Use of non-UL listing products or other regulators may not comply with product regulations in the region(s) in which
the product is sold.
System Power On/Off:
The power button DOES NOT totally turn off the system AC power. To remove the power of the system, you must
unplug the AC power cord from the outlet or the system’s power supply units. Make sure the power cord is unplugged
before you open the chassis, add or remove any components.

3
Hazardous Conditions, Devices and Cables:
Hazardous electrical conditions can be present on/in power supply units and their cables. Disconnect the power cord
and any other devices attached to the server before opening the case. Failing to follow safety procedures will increase
the risk of personal injury or equipment damage.
Electrostatic Discharge (ESD) and ESD Protection:
In most cases, ESD may damage disk drives, electronic boards and other parts. We recommend that you conduct
installation only at an ESD free space. If not possible, perform ESD protection protocol by wearing anti-static wrist
straps attached to the ground on any unpainted metal surface on your server during operation.
Installing or Removing Jumpers:
A jumper is a short length conductor used to close, open or bypass part of an electronic circuit. Jumpers on InWin
backplanes have a small tab on top that you can pick up with your fingertips. Grip the jumper carefully and plug the
jumper to cover the jumper pins on the backplane. Once you need to remove the jumper, grip the jumper and carefully
pull without squeezing.
CAUTION
To avoid damage and maintain your safety, please read the following terms listed below:
1. Do not populate hard drives and turn on the power until the system has stabilized. Make sure hard drives and other
components are properly connected before turning on the system.
2. Tighten or loosen all screws with a screwdriver.
3. Apply the correct screws packed in the accessories box.
4. For your safety, please have at least two people lift and install the unit in its designated area.
5. Before mounting the unit to the cabinet, make sure the rail is installed correctly.
6. When installing and removing any module or part, please use the handles.

4
When you open the IW-RS216-07 box, the contents should include following:
1.1 Box Contents
1 Product Introduction

1 2 3
4 5 6
5
1.2 Accessories Box
No. Item
1Hexagon Head Screws x 12
Motherboard Stand-off Sockets x 12
22.5" HDD Screws x 24
3Power LED 3-pin to 2-pin Adapter x 1
No. Item
4Backplane Jumper x 2
5Cables Ties and Mounts x 5
6HDD Tray Mark Label x 1

83.5"/2.5" (15mm) hot-swap drives x 8
9Pull tab
10 Slide rail mounting area
11 ATX, CEB, EEB M/B mounting area
12 Low-profile PCI slots x 7
13 Rear I/O shield mounting area
14 Rear 2.5" hot-swap SSD trays x 2
15 80 PLUS Platinum CRPS (including PDB)
1Top cover
2Top cover screwless open button
380 x 38mm PWM hot-swap fans x 4
4Bottom layer backplane
*5 Top layer backplane cage kits mounting area
5a Top layer type 1 backplane cage kits
5b Top layer type 2 backplane cage kits and
metal frames for installation
6Server rack cabinet mounting ears
7Front controls and indicator
6
When you open the chassis, it should reflect the diagram’s image.
1.3 General Information
1
1
2
3
4
*
7
or
8
6
6
5
5a
5b
13
14
15
12
11
10
9
•5a(1pc): top layer type 1 OCuLink backplane and 2.5" 15mm HDD trays x 2
•5b(1pc): top layer type 2 OCuLink backplane and 2.5" 7mm HDD trays x 4
*Backplane Cage Kit (pre-installed x 2pcs):
* 5a(1pc) and 5b(1pc) are exchangeable for each other.

1
3
5
2
4
6
9
8
8
77
7
The IW-RS216-07 supports 3.5"/2.5"(15mm) SAS/SATA/NVMe disk bays x 8 pair optional
2.5"(15mm) SAS/SATA/NVMe or 2.5"(7mm) SAS/SATA/NVMe disk bays. Maximum supports U.2
NVMe disk bays x 16. The control panel, USB I/O ports and indicators are located on the handles.
1.3.1 Front Panel Controls and Indicators
No. Name Color Status Description
1System Reset Button N/A Press the button to activate system reset.
2NMI Button N/A Press the button to activate user-defined function.
3Power On/Off Button
with LED
Green Solid on System is powered on.
N/A Off System is off.
4Chassis ID Button
with LED Blue Solid on Press the button to activate system identification.
5Hard Disk LED Amber Blinking System HDD accessing.
6System Fail LED
Amber Solid on System Status ( - , + ).
Green Solid on System Status ( + , - ).
7
LAN LED (From top to
bottom ranked LAN1-
LAN4)
Green Blinking Link between system and network.
N/A Off No data transmission or receiving is occurring.
8USB 3.0 Connector N/A USB devices connections.
9Maximum supports NVMe x 16 disk bays for faster hybrid storage performance.
3.5"/2.5"(15mm) disk bays x 8 pair 2.5"(15mm) disk bays x 4
3.5"/2.5"(15mm) disk bays x 8 pair 2.5"(7mm) disk bays x 8

1
2
3
4
5
No. Name Description
1Power Module 1 Default primary power supply module.
2Power Module 2 Backup power supply module.
3OS HDD
This slot is for InWin OS disk backup module (optional),
which supports two 2.5" 12G SSDs and features hot-swap
function.
4System I/O
(Depends on M/B Specifications)
The I/O shield should come with the motherboard or is
provided by motherboard vendors.
5Low-profile PCIe slots x 7 The slots support low-profile cards. The bracket should be
removed before using.
8
1.3.2 Rear Panel Conguration

9
Before installing the motherboard, please find the I/O shield from your motherboard package
and install it into the system I/O window. If you cannot find the I/O shield, please check with your
motherboard vendor, or contact InWin for I/O shield OEM service.
2 Hardware Installation
For a quick installation video, please visit 07 Series Motherboard & Expansion Card.
2.1 Motherboard & Expansion Card Installation
The IW-RS216-07 features tool-less trays. Users no longer need to use screws to mount disks, and
can swap drives faster.
For a quick installation video, please visit 07 Series HDD Tray Installation.
2.2 HDD Tray Installation
The IW-RS216-07’s built-in fan modules feature a tool-less design, which makes it easy to maintain.
For a quick installation video, please visit 07 Series Fan Installation.
2.3 Fan Installation
The IW-RS216-07 has a built-in redundant power supply unit. With this function, the system is
capable of operating if one of the modules fails. To replace it, users only need to release the failed
module, and then insert a functional module.
For a quick installation video, please visit 07 Series Power Supply Installation.
2.4 Power Supply Installation

10
● 2.4.1 Power Supply Cable Information
Length Unit: mm
24 Pin Main Motherboard
340mm
8 Pin CPU
250mm
8 Pin CPU
380mm
8 Pin BP
450mm
6 Pin BP
430mm
4 Pin 2.5" 15mm HDD BP
280mm
Altri manuali per IW-RS216-07
2
Indice
Altri manuali InWin Server

InWin
InWin IW-RS424-04 Manuale utente

InWin
InWin IW-RN316-04 Manuale utente

InWin
InWin IW-PL070 Manuale utente

InWin
InWin IW-RS208-04 Manuale utente

InWin
InWin IW-PLG Tower Manuale utente

InWin
InWin IW-RS112-08 Manuale utente

InWin
InWin IW-RS208-07 Manuale utente

InWin
InWin IW-RN424-04 Manuale utente

InWin
InWin IW-MS08-A Manuale utente

InWin
InWin IW-RS448-05 Manuale utente