ITL MON-2697-COM Manuale utente

Toll Free: +1 (866) 624-8309 www.itl-llc.com
Monitoring
System
For
ILS-2600/3600

MON
-
2697
-
COM
DOC-2697-MNL Rev0.docx Copyright 2023 ITL, LLC Page 2 of
24
Front Matter
Copyright & Trademarks
Copyright © 2023 by ITL, LLC. All rights reserved. This document contains proprietary
information, photographs, graphics, and other material (collectively, "the Content")
protected by copyright, and this manual and all accompanying hardware, software and
documentation are copyrighted. No part of this document may be photocopied or
reproduced by mechanical, electronic, or other means in any form without written consent
of ITL, LLC.
“International Tower Lighting, LLC”, ”ITL, LLC”, MON-2680-COM, MON-2697-COM,
MON-800, MON-805, MON-830, MON-920-LAN, MON-930, MON-940, MON-G930, ITL-
2697-COM, ITL-920-LAN, ITL-0930, ITL-0940, ITL-0950, ITL-G930, ADP OnSite, ADP
Lite, ADP Standard, and ADP Enterprise, and the ITL logo are all trademarks of ITL, LLC.
All other trademarks and brand names are the property of their respective proprietors.
Limited Warranty and Disclaimer
ITL, LLC guarantees that every MON-2697-COM monitoring system is free from physical
defects of material and workmanship under normal use for one (1) year from the date of
purchase. If the product proves defective during this warranty period, please contact ITL,
LLC in order to obtain a Return Authorization Number, RMA.
In no event shall ITL, LLC’s liability exceed the price paid for the product from direct,
indirect, special, incidental, or consequential damages resulting from the use of the
product, its accompanying software, or its documentation. ITL, LLC makes no warranty
or representation, expressed, implied, or statutory, with respect to its products or the
contents or use of this documentation and all accompanying software, and specifically
disclaims its quality, performance, merchantability, or fitness for any particular purpose
unless otherwise stated.
The technical documentation is being delivered to you AS-IS. ITL, LLC makes no
warranty as to its accuracy or use. Any use of the technical documentation or the
information contained therein is at the risk of the user. Documentation may include
technical or other inaccuracies or typographical errors. ITL, LLC reserves the right to
revise or update its products, software, or documentation without obligation to notify any
individual or entity.

MON
-
2697
-
COM
DOC-2697-MNL Rev0.docx Copyright 2023 ITL, LLC Page 3 of
24
Safety Warning
This equipment uses lethal voltages which can cause serious injury and/or death. Do not
attempt to service this equipment with line power applied.
Never rely on just one switch to power down a high voltage supply.Measure for voltages
using a voltmeter to ensure that power is off and has been completely removed.
Do not wear any jewelry when servicing this equipment. Gold and silver are excellent
conductors of electricity.
Battery Warning and Disposal
There is danger of explosion if the included sealed lead-acid battery is replaced
incorrectly. Only replace the battery with the same or equivalent type recommended by
the battery manufacturer. Dispose of used batteries according to the battery
manufacturer's instructions.
Do not incinerate, disassemble, or puncture the battery.
For questions or details please contact The Battery Council International at (312) 664-
6610, or your local waste agency.

MON
-
2697
-
COM
DOC-2697-MNL Rev0.docx Copyright 2023 ITL, LLC Page 4 of
24
Table of Contents
Front Matter....................................................................................................................... 2
Copyright & Trademarks ................................................................................................ 2
Limited Warranty and Disclaimer ................................................................................... 2
Safety Warning .............................................................................................................. 3
Battery Warning and Disposal ....................................................................................... 3
List of Illustrations and Tables ........................................................................................... 5
Introduction........................................................................................................................ 6
Product Description ........................................................................................................... 6
Specifications .................................................................................................................... 6
Environment................................................................................................................... 7
Mechanical..................................................................................................................... 7
Electrical ........................................................................................................................ 7
Communication Module ................................................................................................. 7
Installation ......................................................................................................................... 8
Unpacking your Monitoring System ............................................................................... 9
Tools for Installation....................................................................................................... 9
Quick Installation Guide ................................................................................................. 9
1. Ethernet Connection ............................................................................................. 10
2. Modem Power and Battery Connections .................................................................. 10
3. Modem Power (5VDC) ............................................................................................. 11
Web Pages...................................................................................................................... 12
SNMP .............................................................................................................................. 14
1. Object Identifiers (OIDs) and Names ....................................................................... 14
System OIDs ............................................................................................................ 14
Product OIDs............................................................................................................ 15
Trap Setup OIDs ...................................................................................................... 16
MON-2697-COM Alarm OIDs................................................................................... 17
MON-2697-COM Configuration / Status OIDs.......................................................... 18
ILS-2600/2600 Beacon #1 … #4 OID Overview....................................................... 19
ILS-2600/2600 Beacon #1 Alarm OIDs .................................................................... 20
ILS-2600/2600 Beacon #1 Configuration OIDs ........................................................ 21
ILS-2600/2600 Beacon #1 Status OIDs ................................................................... 22
ILS-2600/2600 Beacon #1 Mode/PEC OIDs ............................................................ 23
Technical Support and Contact Info ................................................................................ 24
Contact Info ................................................................................................................. 24
RMA............................................................................................................................. 24

MON
-
2697
-
COM
DOC-2697-MNL Rev0.docx Copyright 2023 ITL, LLC Page 5 of
24
List of Illustrations and Tables
Figure 1: MON-2697-COM Circuit Board Assembly .......................................................... 8
Figure 2: MON-2697-COM Ethernet Connection............................................................. 10
Figure 3: Modem power (12VDC) shown in red box. Backup battery input shown in yellow
box. .......................................................................................................................... 10
Figure 4: 5VDC modem power output. ............................................................................ 11
Figure 5: MON-2697-COM Web Login ............................................................................ 12
Figure 6: MON-2697-COM Alarm Page........................................................................... 13
Figure 7: System OIDs .................................................................................................... 14
Figure 8: Product OIDs.................................................................................................... 15
Figure 9: Trap Setup OIDs .............................................................................................. 16
Figure 10: MON-2697-COM Alarm OIDs......................................................................... 17
Figure 11: MON-2697-COM Configuration OIDs............................................................. 18
Figure 12: ILS-2600/3600 Beacon #1Alarm OIDs ........................................................... 20
Figure 13: ILS-2600/3600 Beacon #1 Configuration OIDs .............................................. 21
Figure 14: ILS-2600/3600 Beacon #1 Status OIDs ......................................................... 22
Figure 15: ILS-2600/3600 Beacon #1 Mode/PEC OIDs .................................................. 23

MON
-
2697
-
COM
DOC-2697-MNL Rev0.docx Copyright 2023 ITL, LLC Page 6 of
24
Introduction
Congratulations, and thank you for choosing an ITL monitoring system.
We trust that ITL’s reputation for technical excellence, experience in product
development, commitment to our customers and testing will ensure your complete
satisfaction.
You have chosen one of the most technologically innovative monitoring systems for
monitoring tower lighting systems available on the market today. This product is the
result of many years of engineering with extensive input from field service personnel.
This manual covers MON-2697-COM monitoring system which can function as either
hardwired Ethernet or wireless monitoring system with the addition of a wireless modem.
Please consult ITL technical support for specific modem selections.
Please take the time to read and familiarize yourself with this manual. It contains the
information necessary to install, test and troubleshoot the MON-2697-COM monitoring
system or consult the Quick Installation Guide.
Product Description
ITL’s MON-2697-COM is designed to provide a complete monitoring solution for ILS-2600
and ILS-3600 LED tower lighting systems. The monitoring system’s rich set of features is
directly applicable to monitoring all aspects of these two LED lighting systems.
All MON-2697-COM controllers are SNMP enabled and support SNMP v1 and SNMP v2c
capabilities to allow for M2M communication. Additionally, the system has built-in web
pages to provide a more intuitive human interface and is supported by most web
browsers.
Both, hardwired Ethernet connection and wireless modem communication are also
supported.
Typical wireless applications include the use of a secure software tunnel provided by a
third party for communication between the MON-2697-COM (Agent) equipment and
network management system (NMS) or SNMP manager.
Specifications

MON
-
2697
-
COM
DOC-2697-MNL Rev0.docx Copyright 2023 ITL, LLC Page 7 of
24
Environment
Temperature -40ºC to +55ºC
Humidity less than 95% relative humidity (non-
condensing)
Mechanical
Board Assembly Dimensions Height: 9.00” (229mm)
Width: 7.50” (191mm)
Depth w/o Modem: 1.50” (38.1mm)
Depth w/Modem: 3.00” (76.2mm)
Weight w/o Modem 1.4 lbs (0.620Kg) max
Weight with Modem 2.4 lbs (1.075Kg) max
Electrical
Input Power 120/240VAC at 60Hz, 12VA (max.)
Suppression 45 Joule, 275V, Input Power
23 Joule, 275V, Spare Relay
Spare Output Relay 120/230 VAC, 1 Amp, Form-C
Communication Module
Digi IX10

MON
-
2697
-
COM
DOC-2697-MNL Rev0.docx Copyright 2023 ITL, LLC Page 8 of
24
Installation
The MON-2697-COM monitoring system installs directly on the interior door of the ILS-
2600 or ILS-3600 enclosure as indicated below.
Figure 1: MON-2697-COM Circuit Board Assembly

MON
-
2697
-
COM
DOC-2697-MNL Rev0.docx Copyright 2023 ITL, LLC Page 9 of
24
Unpacking your Monitoring System
Please examine the shipping containers and their content thoroughly upon receipt and
report any potential shipping damage to the carrier.
Tools for Installation
The following tools are suggested for mounting of the MON-2697-COM monitoring
system.
Nut Driver and 9mm Socket
Quick Installation Guide
The quick start guide shows how to install the MON-2697 series monitoring system. The
guide provides only basic instructions to personnel familiar with these types of
installations. For more details, refer to this document or contact ITL technical support
staff.
Install MON-2697-COM to interior of ILS-2600/3600 enclosure door
Connect
o3 pin Phoenix style power connector
oRibbon cable (RS485 communication)
oEthernet cable for hardwire connection or modem w/antenna
Apply power to unit and observe functioning LEDs
Open web browser with above IP number, use ‘admin/Admin2017’ for default
username/password
Configure SNMP and basic network settings as needed via webpages

MON
-
2697
-
COM
DOC-2697-MNL Rev0.docx Copyright 2023 ITL, LLC Page 10 of
24
Circuit Board
1. Ethernet Connection
2. Modem Power and Battery Connections
Observe polarity when connecting and disconnecting the battery. Note all battery
warnings in the Safety Warning section.
Observe polarity when connecting the modem power.
Figure 2: MON-2697-COM Ethernet Connection
Figure 3: Modem power (12VDC) shown in red box. Backup battery input shown in yellow
box.
Indice

















