JensPrima innoCon 6800O Manuale utente

WALL MOUNTING JENSPRIMA INSTRUMENTS
Online Dissolved Oxygen Analyzer
Operating Instruction
innoCon 6800O
PRIMA_O2_3BC6051
NORMAL ATCREL WASH
4.88
mg/l
C
25.0
12
O
O2


Restore
innoCon 6800 Monitor Manual
www.jensprima.com
Contents
Safety 2
3
5
5
6
7
8
9
10
11
12
13
13
16
17
....................................................................
......................................................
...............................................................
.....................................................
Display ...................................................................
......................................................
.........................................................
Maintenance .............................................................
General ...............................................................
.................................................
....................................................
6
.........................................................
5
................................................
Analysis System .......................................................
14
14
14
15
Zero Calibraon
Concentraon Calibraon
........................................................
................................................
................................................................
Output ...............................................................
Interface ..............................................................
Diagnosis ..............................................................
(RS485)......................................
Page 1
jens

innoCon 6800 Monitor Manual
Page 2
Safety
Legal requirements
Sensor
Signs
√ This manual introduces all the risks that may arise during the use of this equipment,
√ Please make sure this manual is delivered to the third party along with innoCon 6800.
.
Please use sensors manufactured by jensprima; Damages to the instrument caused by
the use of sensors not manufactured by jensprima within the warranty period will not
be covered by the warranty.
Only technicians authorized by jensprima can modify and update the instrument.
jensprima is exempt from any damage to the instrument arising from modifica�on or
upda�ng by unauthorized personnel.
of corresponding regions and countries.
This sign is used to instruct the operator.
!
www.jensprima.com
jens

PRIMA_O2_3BC6051
NORMAL ATCREL WASH
4.88
mg/l
C
25.0
12
O
O2
innoCon 6800 Monitor Manual
The innoCon 6800O intelligent controller is designed for water treatment and industrial
process monitoring. The innoSens series DO electrode can measure dissolved oxygen
and temperature (ppb/ppm )in water, with automac temperature compensaon, a
variety of installaon methods, standard 4-20mA/RS485 output and a variety of control
funcon output. Both Chinese and English menus, users can do programming on their
own.
Sewage andindustrial wastewater treatment,fish farming and potable water.
1. innoCon 6800O controller
2. Electrode holder
3. Manuals
4. innoSens 420/425 (addional purchase)
Features
√ Large backlit LCD display for readings, temperature and status of relays
mistakes
√ 2 groups of relays to be set at Hi/Lo output
√ Auto cleaning relay output
√ 2 lines of 4-20mA current/RS485 Modbus output
Page 3www.jensprima.com
jens

Parameter
Range
Dissolved Oxygen
Temperature sensor
Ambient temperature
Stored temperature
Chinese/English
Large LCD backlit display
Analog Output 1
Analog Output 2
Language
Power
Cutout size
Weight
innoCon 6800 Monitor Manual
Page 4
-10.0~120.0℃
0~70.0℃
-20~70.0℃
0~200.0μg/L, 0~20.00mg/L, 0~200%, -10.0~120.0℃
0.1μg/L, 0.01mg/L, 0.1℃
±1%f.s., ±0.2℃
Pt 1000/NTC 10K
Accuracy
Unit μg/L,ppb,mg/L,ppm,%
Display
4 to 20mA for Dissolved Oxygen, load < 600Ω
4 to 20mA for Temperature, load < 600Ω
RS485 Modbus RTU
IP65
138 x 138mm
144 x 144 x 110mm
innoSens 420 DO Electrode
Suitable for measuring dissolved oxygen in 0~20.00mg/L (ppm) water, such as sewage
treatment, aquaculture, etc.
innoSens 425 DO Electrode
Suitable for the measuring dissolved oxygen in water from 0 to 200.0 g/L (ppb), such as
boiler feed water, condensed water, etc.
0.85Kg
2 sets of ON/OFF relay and one set of Wash relay, Hi/Lo
alarm points can be set independently, with hysteresis
Relay
Wash Relay
Size
innoSens Series DO Electrode (Amperometric Method)
Please refer to the
detailed technical
documents and
choose appropriate
sensor
www.jensprima.com

innoCon 6800 Monitor Manual
The instrument can be flush mounted, pipe mounted and wall mounted.
Make a hole of 138 x 138mm on the instrument case, put the instrument into the case
from the front of the panel of the case, insert screws from the back cover, and then
lock the fastening block to the fastening bar from the back of the panel.
Size
Page 5
Cut size
138mm
110mm
138mm
144mm
144mm
80mm32mm
72mm
6,2mm
www.jensprima.com
jens

JENSPRIMA has membrane dissolved oxygen electrodes in ppm and ppb grade,
ppm level(innoSens 420: 0~20.00ppm)
ppb level(innoSens 425)
Note:
the electrodes
innoCon 6800 Monitor Manual
Page 6
PRIMA_pH_1BC6051
NORMAL ATCREL WASH
7.00 pH
C
25.0
12
O
innoSens 425:0~20.00ppm、0~200.0ppb
Immersion type
O ring
O ring
Molded shell electrode(3/4”thread)
Recommend to wrap the thread with tape
Fixed bracket
Water-proof cable
connector
www.jensprima.com
inlet
outlet

contacts(AC<250V/5A, DC<30V/5A)
relay1
relay2
wash relay
innoCon 6800 Monitor Manual
The connectors of the controller are located behind the instrument cover, and only
supply, relay and signal output.
Danger:
be carried out by technicians
with special training.
Notes:
Power supply must be cut off
otherwise the instrument and
the sensor are likely to be
damaged.
Page 7
power(90-260Vac)
sensor
--live wire of power supply
--neutral wire of power supply
RS485 output
--Temperature
--Temperature 1
--Temperature 2
-- Dissolved oxygen
Analog current output
ANODE
CATHODE
SHIELD
www.jensprima.com
jens
Terminals
Page 7
www.jensprima.com
CATHODE(Clear)
ANODE
SHIELD(Red )
(Green)
TEMP(Black )
TEMP(White)

PRIMA_O2_3BC6051
NORMAL ATCREL WASH
4.88
mg/l
C
25.0
12
O
O2
innoCon 6800 Monitor Manual
Display
Front view of the controller
Measurement parameter
Measurement
value
Status
NORMAL --
REL 1,2 -- status of Relay 1 and 2
WASH -- status of the washing relay
ATC --
MTC(manual)
Menu key
Back key
Enter key
Arrows key
Return to previous menu.
Accept the figure input or menu chosen.
or off the backlight of the display.
Entry into the setup mode is protected by password. The default password is 0022.
to the previous menu. You can return to the measurement mode by pressing this
Page 8
PRIMA_O2_3BC6031
NORMAL ATCREL WASH
4.88
mg/l
C
25.0
12
O
www.jensprima.com