Jung FAS180 Series Manuale utente

Radio automatic switch 180°
Radio Management
Radio automatic switch 180°
Art. No. : ..FAS180..
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
The radio communication takes place via a non-exclusively available transmission path,
and is therefore not suitable for safety-related applications, such as emergency stop and
emergency call.
Keep button cells out of reach of children! If button cells are swallowed, get medical help
immediately.
Risk of explosion! Do not throw batteries into fire.
Risk of explosion! Do not recharge batteries.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1
(1) Base plate
(2) Frame
(3) Radio motion detector
(4) Cover
3 Function
System information
By statute, the transmitting power, the reception characteristics and the antenna cannot be
changed.
The range of a radio system from the transmitter to the receiver depends on various
circumstances.
The range of the system can be optimised by selecting the optimal installation location, taking
into account the structural circumstances.
1/8
32552843
J0082552843 16.08.2016

Figure 2: Reduced range due to structural obstacles
Example of penetration of various materials:
Material Penetration
Wood, Plaster, Plasterboard approx. 90%
Brick, Chipboard approx. 70%
Reinforced concrete approx. 30%
Metal, Metal grid approx. 10%
Rain, Snow approx. 1-40%
Intended use
- Motion detector for automatic switch-on of lighting depending on heat motions and ambient
brightness
- Operation in conjunction with radio power pack and suitable radio actuators
- Surface-mounting
iThe motion detector is not secured against tampering, and is therefore not suitable for use
in alarm systems.
Product characteristics
- The motion detector detects heat motions caused by people, animals and inanimate
objects.
- Sensitivity can be set
- Brightness value can be set
- Detection area can be limited using cover plate
- Battery-powered device
Response when actuators switched on
- A dimmer actuator which is switched on switches on to the stored switch-on brightness
when a motion detector telegram is received. When the run-on time elapses, the brightness
previously set manually is restored.
- A switched-on radio switch actuator remains switched on when a motion detector telegram
is received and after the run-on time elapses.
2/8
32552843
J0082552843 16.08.2016
Radio Management
Radio automatic switch 180°

4 Information for electrically skilled persons
4.1 Fitting and electrical connection
Selecting the installation location
Figure 3: Detection planes
At an installation height of 1.10 m the motion detector has a detection field with an aperture
angle of 180° in 2 planes (figure 5).
Figure 4: Detection area
Size of the detection field: approx. 10 m x 12 m, semi-oval (figure 5). The information on the
size of the detection field refer to an installation height of 1.10 m. The nominal range varies for
different installation heights.
iThe orientation of the upper lens plate does not limit the detection field in space. Therefore
in some circumstances even motions outside of the specified detection field may trigger
switching operations.
Several basic principles must be taken into account when selecting the installation location.
oSelect a vibration-free installation location; vibrations can lead to unwanted switching.
3/8
32552843
J0082552843 16.08.2016
Radio Management
Radio automatic switch 180°

Figure 5: Installing the motion detector laterally to the direction of movement
The motion detector can detect motions optimally if it is installed laterally to the direction of
movement. Otherwise detection is likely to occur too late (figure 5).
oDo not touch the sensor window.
Figure 6
oMake sure that there are no sources of interference, such as lamps or heaters, in the
detection field (figure 6): select the most appropriate installation location and/or use push-
on cover (see section "Limiting the detection area").
iReflection of heat radiation from the lighting, or insufficient distance between the motion
detector and luminaires may result in repeated switch-on.
Fitting the motion detector
iBefore fitting, first perform the teaching procedures and adjustments if necessary (see
sections "Teaching motion detector in radio receiver" and "Setting the sensitivity and
brightness setpoint).
oInset battery if necessary (see section Changing the battery).
The cover plate for limiting the detection area is preinstalled at the factory! In order to monitor
the entire detection area, the cover plate has to be removed.
The "Top" label on the base plate has to be at the top.
oGlue or screw the base plate (1) of the motion detector (3) directly to an even surface.
oCarefully fit motion detector with frame (2) on the guide pins of the base plate. The battery
holder must fit in the corresponding aperture in the base plate.
4/8
32552843
J0082552843 16.08.2016
Radio Management
Radio automatic switch 180°

Changing the battery
WARNING!
Risk of chemical burns.
Batteries can burst and leak.
Replace batteries only with an identical or equivalent type.
oCarefully pull motion detector (3) with frame (2) off of the base plate (1) (figure 1).
Figure 7: Remove battery
oRemove empty battery carefully using a screwdriver (figure 7).
Figure 8: Insert battery
iKeep contacts of batteries and device free of grease.
oApply new battery to the positive contact of the battery holder. Observe correct polarity: the
positive pole of the battery must be at the top (figure 8).
oPress gently on battery to snap it in.
oCarefully fit motion detector with frame on the guide pins of the base plate. The battery
holder must fit in the corresponding aperture in the base plate.
5/8
32552843
J0082552843 16.08.2016
Radio Management
Radio automatic switch 180°

iAfter the battery is inserted the red LED lights up for approx. 1 minute. After that the motion
detector is in the walking test/teach mode for approx. 10 minutes (see chapter Teaching
motion detector in radio receiver). This is displayed by rapid flashing of the LED. No
actuator may be in programming mode during this time. Otherwise undesirable teaching
will take place.
4.2 Commissioning
Teaching motion detector in radio receiver
In order for a receiver to understand a radio telegram from the motion detector, the receiver has
to "learn" this radio telegram. The motion detector can be taught in any number of radio
receivers. The teaching procedure only results in an assignment in the radio receiver.
When teaching a radio transmitter, the range of the receiver is reduced to about 5 m. The
distance between the radio receiver and the transmitter being taught should therefore be
between 0.5 m and 5 m.
oRemove battery from the motion detector for approx. 2 minutes.
oInsert battery again.
After the battery is inserted the red LED lights up for approx. 1 minute. Then the motion
detector is in walking test/teach mode for approx. 10 minutes. This is displayed by rapid
flashing of the LED. In this mode the motion detector evaluates motions regardless of the
brightness. Every telegram transmitted here can be taught in the radio receiver.
oTest the detection area by walking over it and mount push-on cover if necessary (see
"Limiting the detection area").
Each telegram transmitted switches the receiver on for approx. 2 seconds.
iIf the motion detector does not detect any motion for approx. 2 minutes, then it
automatically exists the walking test / teaching mode.
oSwitch radio receiver to programming mode (see instructions for receiver).
oMake a motion in the detection field of the motion detector so that it transmits a teaching
telegram.
The red LED of the motion detector flashes approx. 4 times.
The radio receiver acknowledges the teaching procedure (see instructions for the radio
receiver).
oExit programming mode of the radio receiver (see instructions for the radio receiver).
Setting the sensitivity and brightness setpoint
Figure 9: Adjuster under cover
oPry out cover (3) carefully from below using a screwdriver.
oUse the sensitivity controller Sens. (6) to adjust the sensitivity of the sensor between
maximum and minimum sensitivity (figure 9).
6/8
32552843
J0082552843 16.08.2016
Radio Management
Radio automatic switch 180°

oUse the brightness setpoint controller (7) to adjust the brightness setpoint:
Symbol Moon: approx. 0 lux,
Just before the Sun symbol end stop: approx. 80 lux,
Sun symbol end stop: brightness-independent switching or daytime operation.
The change in the setting is only applied when no motion is detected for 2 minutes.
iSet the brightness setpoint on the radio motion detector to approx. 80 lux in connection
with a radio power pack. This value is located just before the end stop in the direction of
the Sun symbol. The desired brightness threshold can then be set directly on the radio
power pack.
iThe run-on time is specified by the radio actuators. The run-on time can be set from
10 seconds to 15 minutes on the motion detector power pack. For switch and dimmer
actuators the run-on time is approx. 1 minute.
Limiting the detection area
Figure 10
The supplied cover plate (10) can be used to mask unwanted detection areas (figure 10). The
cover plate can cover up the left (8) or right half (9) of the detection fields, 90° in each case.
iAlways use the entire cover plate! Cutting out the cover plate to a smaller angle will result
in malfunctions.
oFit cover plate on sensor window.
5 Appendix
Remove empty batteries immediately and dispose of in an environmentally friendly
manner. Do not throw batteries into household waste. Consult your local authorities
about environmentally friendly disposal. According to statutory provisions, the end
consumer is obligated to return used batteries.
5.1 Technical data
Rated voltage DC 3V
Battery type 1×Lithium CR 2450N
Ambient temperature +5 ... +35°C
Relative humidity max. 65% (No moisture condensation)
Brightness setting approx. 0 ... 80lx (and day operation)
Installation height 1.10m
Detection angle 180°
Detection area approx. 10 x 12 m
Radio frequency 433.05MHz ... 434.79MHz
Transmitting range in free field typ. 60m
7/8
32552843
J0082552843 16.08.2016
Radio Management
Radio automatic switch 180°

Transmission capacity < 10mW
5.2 Troubleshooting
LED behind the sensor window flashes approx. 10 times during a transmission.
Cause: battery in the motion detector is almost empty.
Change battery (see section changing the battery).
Motion detector does not respond.
Cause 1: sensitivity Sens. of the motion detector is set too low.
Increase sensitivity Sens. (see section "Setting the sensitivity and brightness setpoint" and
"Run-on time").
Cause 2: battery in the motion detector is empty.
Change battery (see section changing the battery).
Cause 3: Radio range exceeded.
Check the installation situation. Structural obstacles reduce the range.
Using a radio repeater.
Motion detector responds permanently.
Cause 1: sensitivity Sens. of the motion detector is set too high.
Decrease sensitivity Sens. (see section "Setting the sensitivity and brightness setpoint").
Cause 2: the motion detector is in the walking test / teaching mode.
Wait 2 minutes with no motion in the detection field, otherwise 10 minutes. After that the
walking test / teaching mode is exited automatically.
Cause 3: There is a continuous motion in the detection field of the motion detector.
Eliminate cause of the continuous motion.
5.3 Conformity
Albrecht Jung GmbH & Co. KG hereby declares that the radio system type
Art. No. ..FAS180..
corresponds to the directive 2014/53/EU. You can find the full article number on the device. The
complete text of the EU Declaration of Conformity is available under the Internet address:
www.jung.de/ce
5.4 Warranty
The warranty follows about the specialty store in between the legal framework as provided for
by law.
ALBRECHT JUNG GMBH & CO. KG
Volmestraße 1
58579 Schalksmühle
GERMANY
Telefon: +49 2355 806-0
Telefax: +49 2355 806-204
www.jung.de
8/8
32552843
J0082552843 16.08.2016
Radio Management
Radio automatic switch 180°
Indice
Altri manuali Jung Interruttore

Jung
Jung 1202 URE Manuale utente

Jung
Jung Home Manuale utente

Jung
Jung 567 S Series Manuale utente

Jung
Jung 1701PSE Manuale utente

Jung
Jung 3281-1 Series Manuale utente

Jung
Jung 10911ST Series Manuale utente

Jung
Jung 1704ESE Manuale utente

Jung
Jung 1180 Series Manuale utente

Jung
Jung LB management Manuale utente

Jung
Jung 3181-1 Series Manuale utente

Jung
Jung 1701SE Manuale utente

Jung
Jung DAW 360 WW Manuale utente

Jung
Jung A3181-1-01 Manuale utente

Jung
Jung 10911STRF Series Manuale utente

Jung
Jung KNX 3281-1 Series Manuale utente

Jung
Jung FMAS10ZS Manuale utente

Jung
Jung 1701 SE Manuale utente

Jung
Jung FMAS816REG Manuale utente

Jung
Jung 1254 TSE Manuale utente

Jung
Jung 1704ESE Manuale utente