KBR multimess 1D4 Manuale utente

EDEBDA0193_1112-1_GB
multimess
System I English
User manual
Technical parameters
1D4
Your partner for
network analysis
Energy measuring device

© KBR Kompensationsanlagenbau GmbH
Subject to technical changes
2

V1.00 3
EDEBDA0193_1112-1_GB
KBR multimess 1D4Introduction
Introduction .............................................................................................................. 5
User manual ............................................................................................................... 5
Intended use .............................................................................................................. 5
Explanation of safety relevant symbols ......................................................... 6
Safety notes ................................................................................................................7
Product liability ........................................................................................................ 8
Disposal ...................................................................................................................... 8
Range of functions ..................................................................................................9
multimess 1D4-BS with multimess 1F96-DS ..................................................9
multimess 1D4-BS with multisio 6D6 and
multisio 6F96-DS ....................................................................................................10
multimess 1D4-BS with multisys 3D2-ESBS ..................................................10
Device overview ....................................................................................................11
Installation ................................................................................................................14
Device assembly ....................................................................................................14
Connections .............................................................................................................15
Start-up ......................................................................................................................16
Start-up of the multimess 1D4 with
multimess 1F96-DS display.................................................................................16
Start-up of the multimess 1D4 at the
multisio 6D6 with multisio 6F96-DS ...............................................................19
Start-up of the multimess 1D4 with
multisys 3D2-ESBS .................................................................................................20
System operation ..................................................................................................20
Conguration of system parameters
in the Extras menu ................................................................................................20
Commi function .....................................................................................................22
Para function .......................................................................................................... 22
Consumption monitoring ..................................................................................22
Menu overview ...................................................................................................... 24
Technical data of the measuring module ..................................................... 28
Measuring accuracy ..............................................................................................28
Measuring principle ............................................................................................. 28
Device memory ......................................................................................................29
Power supply ..........................................................................................................29
Hardware inputs and outputs ............................................................................29
Inputs ..........................................................................................................................29
Outputs .................................................................................................................... 29
Electrical connection.............................................................................................30
Mechanical data ......................................................................................................30

KBR multimess 1D4
V1.00
EDEBDA0193_1112-1_GB
4
Standards and miscellaneous ............................................................................31
Technical data of the measuring module ..................................................... 32
Power supply ..........................................................................................................32
Hardware inputs and outputs ............................................................................32
Electrical connection.............................................................................................32
Mechanical data ......................................................................................................32
Standards and miscellaneous ........................................................................... 33
Protective measures ..............................................................................................33
Overvoltage and lightning protection ...........................................................33
Index .......................................................................................................................... 34

V1.00
KBR multimess 1D4
EDEBDA0193_1112-1_GB
5
1 Introduction
Thank you for choosing this KBR quality product. In order to familiarize
yourself with the operation and conguration of the device, we
recommend that you read this manual thoroughly, so that you are
able to make use of the entire range of functions of this high-quality
product.
The individual chapters serve to explain the technical details of
the device and show how to avoid damage by means of proper
installation and commissioning.
1.1 User manual
This user manual describes the multimess 1D4 device version
with multimess 1F96-DS display. For other device versions, e.g.
for multimess 1D4 on multisio 6D6 with multisio 6F96-DS or
multimess 1D4 with multisys 3D2-ESBS, please read the respective
device manual.
This user manual is included in the scope of delivery of the device
and must be accessible for the user at all times (e.g. in the switchgear
cabinet). Even when the device is resold to third parties, the manual
remains part of the device.
Although we used the utmost care in assembling this user manual, we
would like to thank you in advance for notifying us about any errors or
ambiguous descriptions you might notice.
1.2 Intended use
This device is intended for measuring electrical parameters via
external transformers in the low-voltage network (400VAC Ph-Ph).
Introduction

KBR multimess 1D4
V1.00
EDEBDA0193_1112-1_GB
6
1.3 Explanation of safety relevant symbols
This user manual contains notes that must be observed for your
personal safety and to avoid damage to equipment.
These notes are identied by an i or information symbol,
depending on the degree of hazard they represent.
"Warning" means that death, major injuries or damage may occur in
case the appropriate safety measures are not taken.
"Caution" means that minor injuries or damage may occur in case the
appropriate safety measures are not taken.
"Note" is an important information on the product, its operation or the
respective part of the user manual to which special reference is made.
Disclaimer
The content of this user manual has been carefully reviewed in terms
of the hardware and software described. Certain deviations, however,
cannot be excluded, and the manufacturer is not liable for complete
conformity. The specications made in this user manual are checked
on a regular basis, necessary corrections will be included in the next
revision.
Warning
j
Caution
h
Note
i
Introduction

V1.00
KBR multimess 1D4
EDEBDA0193_1112-1_GB
7
Introduction
1.4 Safety notes
In order to prevent operating errors, operation of this device is
kept as simple as possible. This way, you will be able to quickly start
working with the device.
In your own interest, however, you should read the following
safety notes carefully. During assembly, the applicable DIN / VDE
regulations must be observed!
Power supply connection, setup and operation of the device must
be performed by qualied personnel only. Qualied personnel in
accordance with the safety notes in this user manual are persons
authorized to set up, ground and mark devices, systems and circuits
in accordance with the applicable standards and regulations.
To avoid re and electrical shock, the device must not be exposed to
rain or humidity!
Before connecting the device to the power supply, check whether
the local power supply conditions comply with the specications on
the nameplate.
A faulty connection can lead to the destruction of the device!
When connecting the device, observe the connection chart (see
chapter “Connection chart”) and make sure that no voltage is applied
to the connection lines. Only use proper wiring material and observe
the correct polarity when wiring!
In order to ensure proper and safe operation of the product, it must
be transported, stored, installed and assembled in accordance with
the specications and operated and maintained carefully.
A visibly damaged device must generally be considered unt for use
and disconnected from the power supply!
Error detection, repair and maintenance work may only be carried
out in our facilities or after contacting the service team.
Unauthorized opening of the device voids any warranty. Correct
operation can no longer be guaranteed!
Opening the device may expose live parts. Capacitors in the device
may still be loaded, even if the device has been disconnected from
all voltage sources. It is generally not allowed to operate an open
device!

KBR multimess 1D4
V1.00
EDEBDA0193_1112-1_GB
8
Introduction
In systems susceptible to lightning, lightning protection must be
provided for all input and output lines (for recommendations, see
chapter “Protective measures”)!
1.5 Product liability
You have acquired a high quality product. In its manufacture, only
components of the highest reliability and quality were used. Each
device is subject to long-term testing before it is delivered. Regarding
product liability, we refer to our general terms and conditions for
electronic equipment, which you can nd at www.kbr.de . The
warranted characteristics of the device only apply for operation in
accordance with its intended use!
1.6 Disposal
Defective, outdated or no longer used devices must be properly
disposed of. At your request, we will dispose of the devices for you.

V1.00
KBR multimess 1D4
EDEBDA0193_1112-1_GB
9
Insert battery
2 Range of functions
multimess 1D4 is a multimeter for busbar mounting. On the output
side, it can measure all typical alternating and direct current
parameters of consumers.
The following device expansion stages are possible, featuring dierent
ranges of function:
“multimess 1D4-BS with multimess 1F96-DS” on page 9
“multimess 1D4-BS with multisio 6D6
and multisio 6F96-DS” on page 10
“multimess 1D4-BS with multisys 3D2-ESBS” on page 10
2.1 multimess 1D4-BS with multimess 1F96-DS
Connection of the optional multimess 1F96-DS display can be
established with a ready-made RJ12 cable. For operation of the
display, an additional power supply unit is needed, e. g. the multisys
1D4-PS-24V. This way, no complicated wiring of voltage and current
paths from the converter to the switchgear cabinet door is necessary.
Up to 10 measuring modules can be read out and displayed.
Connection between the modules is also established via ready-made
RJ12 cables.
Power supply of the measuring device is provided by the measuring
voltage. A separate control voltage is not necessary.
multimess 1D4-BS with multimess 1F96-DS is the version described in
this user manual.
Note
i

KBR multimess 1D4
V1.00
EDEBDA0193_1112-1_GB
10
2.2 multimess 1D4-BS with multisio 6D6 and multisio 6F96-DS
If the multimess 1D4 is connected to the multisio 6D6 instead of to
the display, the multisio 6D6 creates a load prole memory (P+ P-/ Q+
Q-) and an eBus interface. Five measuring modules can be connected
to each central storage module Connection between the modules is
established via ready-made RJ12 cables.
2.3 multimess 1D4-BS with multisys 3D2-ESBS
For direct connection of the multimess 1D4 to the KBR eBus, the
multisys 3D2-ESBS gateway is required, which also provides the
supply voltage for the module bus interface via ready-made RJ12
cables. A maximum of 15 measuring modules can be connected
(power consumption of the measuring module interface approx. 0.3
W, power output of the multisys 3D2-ESBS gateway approx. 5 W at 24
VDC). For a larger number of measuring modules, the multisys 1D4-PS-
24V power supply unit is required (power output 24 VDC, 10 W).
3 Device overview
multimess 1D4 measuring module
For busbar assembly (7.5 mm rail)
Connection to measuring voltage Ph-N 230 VAC
Measuring current connection via transformer
x/1A or x/5A
Plug terminal connection 2.5 mm2
RJ12 display connection
RJ12 module bus connection for
supply voltage of the bus interface /
connection of additional measuring modules.
Recording of momentary current
and voltage values.
Continuous energy meter for active and
reactive energy
Indice
Altri manuali KBR Strumento di misura

KBR
KBR multicount D5-0-LCD-1DO-3P-75A-MID Manuale utente

KBR
KBR multicount D5-3P-75A-MID Manuale utente

KBR
KBR multimess 4F96 LCD Manuale utente

KBR
KBR multilog 3 Manuale utente

KBR
KBR multicount 3D6-0-LCD-EP-US1 Istruzioni operative

KBR
KBR multisys 1D3-ESDP Istruzioni operative

KBR
KBR F96 TFT- -5 Series Manuale utente

KBR
KBR F144-2-LED-ESMS 5 Series Manuale utente

KBR
KBR multimess F144-2-LED-ESMS 4 Series Manuale utente

KBR
KBR Multimess F96-***-5 Series Manuale utente