Knick Protos Compa 3400(X)-081 Manuale utente

Communication
Module
Protos COMPA 3400(X)-081
Communication Unit for PROFIBUS PA
The Art of Measuring.
Aktuelle Produktinformation: www.knick.de
Analysenmesssystem
Protos 3400(X)
Betriebsanleitung Messmodul Protos CONDI 3400 (X)-051
zur Leitfähigkeitsmessung mit induktiven Sensoren
Deutsch
The Art of Measuring.
Aktuelle Produktinformation: www.knick.de
Analysenmesssystem
Protos 3400(X)
Betriebsanleitung Messmodul Protos CONDI 3400 (X)-051
zur Leitfähigkeitsmessung mit induktiven Sensoren
Deutsch
Protos 3400(X)
Process Analysis System
User Manual
English
Latest Product Information: www.knick.de

Trademarks
The following trademarks are used in this manual without further marking:
CalCheck®, Calimatic®, Protos®, Sensocheck®, Sensoface®, ServiceScope®, Unical®, VariPower®, Ceramat®,
SensoGate®
are registered trademarks of Knick Elektronische Messgeräte GmbH & Co. KG, Germany
Memosens®
is a registered trademark of
Endress+Hauser Conducta GmbH & Co. KG, Germany
Knick Elektronische Messgeräte GmbH & Co. KG, Germany
SMARTMEDIA®
is a registered trademark of Toshiba Corp., Japan
©2017 Subject to change without notice
Return of Products under Warranty
Please contact our Service Team before returning a defective device. Ship the cleaned device to
the address you have been given. If the device has been in contact with process fluids, it must be
decontaminated/disinfected before shipment. In that case, please attach a corresponding certificate,
for the health and safety of our service personnel.
Disposal
Please observe the applicable local or national regulations concerning the disposal of
“waste electrical and electronic equipment”.
Knick
Elektronische Messgeräte GmbH & Co. KG
Beuckestr. 22
14163 Berlin, Germany
Phone: +49 30 801 91 - 0
Fax: +49 30 801 91 - 200
Web: www.knick.de
Email: [email protected]

3
Table of Contents
COMPA 3400(X)-081 Module
Return of Products under Warranty .................................................................................... 2
Disposal ......................................................................................................................................... 2
Trademarks ................................................................................................................................... 2
Intended Use................................................................................................................................ 5
Conformity with FDA 21 CFR Part 11.................................................................................. 5
Safety Information ..................................................................................................................... 6
Application in Hazardous Locations: COMPA 3400X-081 Module........................... 6
Software Version ........................................................................................................................ 7
Modular Concept ....................................................................................................................... 9
Short Description .......................................................................................... 10
Short description: FRONT module.....................................................................................10
Short Description: Menu Structure....................................................................................11
Short Description: BASE Module........................................................................................13
PROFIBUS Technology................................................................................... 14
Terminal Plate................................................................................................ 16
Inserting the Module .................................................................................... 17
PROFIBUS PA Installation ............................................................................. 18
Communication Model..........................................................................................................20
Physical Block (PB) ...................................................................................................................20
Analog Input Blocks ................................................................................................................21
For Copy: Individual Settings...............................................................................................24
Integration to Project Planning Tools ...............................................................................25
Cyclic Data Communication.................................................................................................26
Structure of Cyclic Input Data Telegram..........................................................................26
DI Function Blocks ...................................................................................................................27
DI 1: Unical Status............................................................................................................27
DI 2: CONTACTS / LOCK Status / ENABLE Request ..............................................27
DI 3: Unical Messages.....................................................................................................28
Explanation of Unical Messages: Maintenance request....................................28
Explanation of Unical Messages: Failure.................................................................29
DI 4: Unical Step...............................................................................................................29
DO Function Blocks .................................................................................................................30
DO 1: HOLD Control .......................................................................................................30
DO 2: PARSET.....................................................................................................................30

4
Table of Contents
COMPA 3400(X)-081 Module
DO 3: Unical Control.......................................................................................................31
DO 4: LOCK Control.........................................................................................................31
Configuration Data..................................................................................................................32
Analog Input Blocks (1 ... 8) ..................................................................................................33
Discrete Input Blocks (1 ...4) .................................................................................................34
Discrete Output Blocks (DO1 ... 4), Analog Output Block AO1................................35
COMPA Slot Model...................................................................................................................36
PB Block Parameters................................................................................................................37
TB Analyser Block Parameters .............................................................................................39
AI Function Block Parameters..............................................................................................41
DI Function Block Parameters..............................................................................................44
DO Function Block Parameters...........................................................................................46
AO Function Block Parameters ...........................................................................................48
Calibration Record Parameters............................................................................................49
Menu Selection.............................................................................................. 61
Passcode Entry............................................................................................... 62
Changing a passcode.....................................................................................................62
Function Control Matrix ........................................................................................................63
Pressure Compensation via Bus (AO1) ........................................................ 64
Diagnostics: Bus Monitor.......................................................................................................65
Bus Monitor ...............................................................................................................................66
Specifications................................................................................................. 67
Process Variables (PROFIBUS) ...................................................................... 69
Module Types PH:.....................................................................................................................69
Calculation Block pH / pH .....................................................................................................69
Module Types O2:.....................................................................................................................70
Calculation Block O2/ O2.....................................................................................................70
Module Types COND:..............................................................................................................71
Calculation Block COND/COND ..........................................................................................71
Module Types CONDI:.............................................................................................................72
Calculation Block CONDI / CONDI......................................................................................72
Index............................................................................................................... 73

5
Intended Use
In their directive “Title 21 Code of Federal Regulations, 21 CFR Part 11,
Electronic Records; Electronic Signatures“ the US American health agency FDA
(Food and Drug Administration) regulates the production and processing of
electronic documents for pharmaceutical development and production. This
results in requirements for measuring devices used for corresponding applica-
tions. The following features ensure that the Protos 3400(X) modular process
analysis system meets the demands of FDA 21 CFR Part 11:
Electronic Signature
Access to the device functions is regulated and limited by individually adjust-
able codes – “Passcodes“. This prevents unauthorized modification of device
settings or manipulation of the measurement results. Appropriate use of these
passcodes makes them suitable as electronic signature.
Audit Trail Log
Every change of device settings can be automatically recorded and
documented in the Audit Trail Log on the SmartMedia card.
The recording can be encrypted.
Conformity with FDA 21 CFR Part 11
The module is a communication unit for PROFIBUS-PA and allows digital
communication via current modulation.
The COMPA 3400X-081 module is intended for operation in locations subject to
explosion hazards which require equipment of Group II, device category 2(1),
gas/dust.

6
Safety Information
Application in Hazardous Locations
Caution!
Never try to open the module! If a repair should be required, return the module
to our factory.
If the specifications in the instruction manual are not sufficient for assessing
the safety of operation, please contact the manufacturer to make sure that your
intended application is possible and safe.
Application in Hazardous Locations: COMPA 3400X-081 Module
The module is approved for operation in hazardous locations.
Observe all applicable local codes and standards for the installation of electrical
equipment in hazardous locations. For orientation, please refer to
IEC 60079-14, EU directives 2014/34/EU and 1999/92/EC (ATEX), NFPA 70 (NEC),
ANSI/ISA-RP12.06.01.
• When installing the device in a hazardous location, observe the specifica-
tions of the EC-Type-Examination Certificate and, if applicable, of the Control
Drawing (download: www.knick.de).
• Before commissioning you must prove that the device may be connected
with other equipment, such as a supply unit including cables and wires.
• In hazardous locations the device shall only be cleaned with a damp cloth to
prevent electrostatic charging.
• Devices and modules which have already been used shall be subjected to
a professional routine test before they may be operated in another zone or
another type of protection.
Be sure to observe during installation:
• Switch off power supply before replacing or inserting a module.
• Before commissioning it must be proved that the device may be connected
with other equipment.

7
Software Version
COMPA 3400(X)-081 Module
Device Software Protos 3400(X)
The COMPA 3400(X)-081 module is supported by software version 5.0 or higher.
Module software version 2.x requires device software version 7.x.
Module Software COMPA 3400(X)-081
Software version 1.3 June 1, 2004
Software version 2.2 April 2, 2007
Software version 2.4 December 10, 2015
Query Actual Device/Module Software
When the analyzer is in measuring mode:
Press menu key, open Diagnostics menu: Device description
Menu Display Device description
Device hardware and software
version
Provides information on all modules
installed: Module type and function,
serial number, hardware and software
version and device options.
Select the different modules (FRONT,
BASE, slots 1 - 3) using the arrow keys.
Device description
Return
22.7 °C
7.00 pH
Operating panel Protos
Module FRONT 3400-011
Hardware: 1.1, Software: A.2
Serial number: 08150815
BASE
Module FRONT
Options
Device description
Return
22.7 °C
7.00 pH
PROFIBUS-PA
Module COMPA 3400-081
Hardware: 1, Software: 2.4
Serial number: 471101147
BASE
Module FRONT
Options
Query module software
Module COMPA 3400-081,
hardware and software version,
serial number –
here installed in slot3.

8

9
Modular Concept
Basic unit, measuring modules, additional functions
Documentation
The basic unit is accompanied by a CD-ROM containing the complete
documentation.
Latest product information as well as user manuals for earlier software
releases are available at
www.knick.de.
The Protos 3400(X) is an expandable modular process analysis system.
The basic unit (FRONT and BASE modules) provides three slots which can be
equipped by the user with any combination of measuring or communication
modules. The software capabilities can be expanded by additional functions
(options). Additional functions must be ordered separately. They are supplied
with a device-specific TAN for function release.
3 module slots
for free combination of
measuring and communication
modules
Measuring modules
• pH / ORP / Temp
• O2/ Temp
• Noncontacting conductivity / Temp
• Contacting conductivity / Temp
• Memosens sensors
Additional functions
Activation via
device-specific TAN
SmartMedia card
Data recording
ProgaLog 3000
Windows® software for
parameter setting and
data evaluation
Protos 3400(X) Modular Process Analysis System
Communication modules
• OUT (additional switching and current
outputs)
• PID (analog and digital controller)
• Profibus PA
• Foundation Fieldbus
• FIU (Memosens, Unical)
(software occupies 2 slots)
• Unical/Uniclean probe controller

10
Short Description
Short description: FRONT module
Transflective LC graphic display
(240 x 160 pixels)
white backlighting, high resolution and
high contrast.
Red LED
signals failure (On) or
maintenance request/function check
(flashing) according to NE 44.
4 captive screws
for opening the analyzer
(Notice! Make sure that the gasket between FRONT and
BASE is properly seated and clean!)
Green LED
Voltage supply okay
5 self-sealing cable glands
M20 x 1.5
for entry of voltage supply and signal lines
2 softkeys
with context-sensitive functions.
User interface
with plaintext menus as recom-
mended by NAMUR.
Menu texts can be switched to:
German, English, French, Italian,
Swedish/Portuguese or Spanish.
Intuitively acquirable menu logic,
based on Windows standards.
Control panel
3 function keys
(menu, meas, enter)
and 4 arrow keys for menu selection
and data entry
Measurement display
Secondary displays
%Air
°C
24.0°C 25.8°C
Indice
Altri manuali Knick Unità di controllo

Knick
Knick Protos MS 3400-160 Manuale utente

Knick
Knick Protos LDO 3400-170 Manuale utente

Knick
Knick Protos 3400 Series Manuale utente

Knick
Knick Protos LDO 4400-170 Manuale utente

Knick
Knick Protos II 4400 Manuale utente

Knick
Knick Protos COMFF 3400-085 Manuale utente

Knick
Knick Protos OXY 3400-067 Manuale utente
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente