Kunbus XPS-E Manuale utente

User Manual
XPS-E
100205 • 02/03/2017

KUNBUS GmbH
ii XPS-E
1 Working with XPS ...........................................................................................................................3
1.1 Validity .......................................................................................................................................3
1.2 User ...........................................................................................................................................3
1.3 Symbols.....................................................................................................................................3
1.4 Safe Work..................................................................................................................................4
1.5 Limitation of Liability ..................................................................................................................5
1.6 Customer Service ......................................................................................................................5
2 Introduction .....................................................................................................................................6
3 Put into operation ...........................................................................................................................7
3.1 Connect the Gateway ................................................................................................................7
3.2 Test the PROFIBUS connection................................................................................................8
3.3 Parametrization .........................................................................................................................9
3.4 set_prm Parametrization .........................................................................................................10
4 Data exchange...............................................................................................................................15
4.1 Send Data................................................................................................................................15
4.2 Receive Data ...........................................................................................................................15
4.3 Send and Receive Data...........................................................................................................24
5 Status and Error Messages..........................................................................................................25
5.1 External Device Diagnostics....................................................................................................25
5.2 Communication Status ............................................................................................................26
6 Connector Assignment and Cabling ...........................................................................................27
6.1 PROFIBUS ..............................................................................................................................27
6.2 Serial Interface ........................................................................................................................29
7 FAQ.................................................................................................................................................32
8 Technical Data...............................................................................................................................33

XPS-E 3 / 36
1 Working with XPS
1.1 Validity
This Document is valid for the following products:
– 100205
1.2 User
The Art may only be assembled, installed and put into operation by
trained, qualified personnel. Before assembly, it is absolutely
essential that this documentation has been read carefully and
understood. Expertise in the following fields is assumed:
– Electronic circuits,
– Basic knowledge of PROFIBUS,
– work in electrostatic protected areas,
– Locally applicable rules and regulations for occupational safety.
1.3 Symbols
The symbols used have the following meaning:
DANGER Hazard
Observe this information without fail!
There is a safety hazard that can lead to serious injuries and death.
WARNING Caution
There is a safety hazard that can result in minor injuries and material
damage.
NOTICE Note
There is a safety hazard that can result in material damage.
Working with XPS-E

XPS-E 4 / 36
1.4 Safe Work
WARNING Damage and serious personal injury due wrong power supply
XPS-E is designed exclusively for PELV operation according to EN 60950 /
EN 60204 / VDE 0805-1
èOnly protective extra-low voltages according to the defined standards
may be used to supply and connect the alarm contact.
NOTICE Electrostatic discharge
The device contains components that can be damaged or destroyed by
electrostatic discharge
èWhen handling the device, observe the necessary safety precautions
against electrostatic discharge (ESD), in accordance with EN 61340-5-1
and EN 61340-5-2, as well as IEC 61340-5-1 and IEC 61340-5-2.
NOTICE Shielding
The shielding ground of the connected twisted pair cables is electrically
connected to the female connector.
èWhen connecting network segments, avoid ground loops, potential
transfers, and voltage equalization currents via the braided shield.
NOTICE Damage due to subsequent processing
Avoid subsequent processing of the FNL.
ØSoldering can cause components to become detached and thus
damage or destroy the module.
ØPlease note that the warranty shall become invalid if the products are
changed technically.
èSpeak to your contact person at the KUNBUS GmbH about customised
solutions.
Working with XPS-E

XPS-E 5 / 36
1.5 Limitation of Liability
Warranty and liability claims will lapse if:
– the product has been used incorrectly,
– damage is due to non-observance of the operating manual,
– damage is caused by inadequately qualified personnel,
– damage is caused by technical modification to the product (e.g.
soldering).
1.6 Customer Service
If you have any questions or suggestions concerning this product,
please do not hesitate to contact us:
KUNBUS GmbH
Heerweg 15 C
73770 Denkendorf
Germany
+49 (0)711 3409 7077
www.kunbus.com
Working with XPS-E

XPS-E 6 / 36
2 Introduction
The intelligent PROFIBUS-DP gateways of the KUNBUS XPS-E
series allow the coupling of any serial devices with RS232 or
RS422/485 interface to PROFIBUS-DP according to the European
Standard EN50170. The protocol conversions required for the
coupling are executed either by means of a transparent universal
driver or by loadable device-specific converters. The following figure
shows a typical connection:
Illustration1: Typical Connection
Introduction

XPS-E 7 / 36
3 Put into operation
3.1 Connect the Gateway
1 2 3 4
5
678
9
10
Illustration2: Connectors and Interfaces of the XPS-E
1 Bus Fail LED 2 Run LED
3 Address Switch x10 4 Address Switch x1
5 Connector for power supply 6 Mode-LED
7 TxD LED 8 RxD LED
9 Serial Interface 10 PROFIBUS Interface
Put into operation

XPS-E 8 / 36
By executing the following steps, the XPS-E Gateway can be set into
operation:
◦ Connect XPS-E to PROFIBUS by using a standard PROFIBUS cable
with corresponding D-SUB PROFIBUS connector. For the connector
assignment please refer to chapter „Connector Assignment and Cabling
[}27]“ and follow the Installation Guidelines for PROFIBUS (No. 2.112,
PNO).
◦ Connect the serial end device with XPS-E
◦ Check your PROFIBUS network with regard to an unused Slave
address and adjust this free address at the coding switch of XPS-E.
◦ Plug in the power supply. The power supply of the XPS-E is connected
by spring clips at the front side.
ðAs soon as the device is powered, the Status/Busfail LED is flashing
red.
NOTICE The Status/Busfail LED is flashing red until the device is
parameterized and configured
In this status, no data exchange can take place (neither send nor receive).
Only after successful parameterization and configuration the Status/Run
LED is flashing green. Now, the device is ready for data exchange.
3.2 Test the PROFIBUS connection
If you have a PROFIBUS-DP configuration tool, you can test the
PROFIBUS connection to the XPS-E Gateway. For this purpose,
load the deliverable GSD file into your configuration tool.
The DP Master shall now configure XPS-E. If this configuration is
successful, the Status/Run LED is flashing green.
If you do not have a PROFIBUS-DP configuration tool or if you wish
to change the pre-defined parameters (User_Prm_Data) in the GSD
file, please refer to the following chapters for the parameterization.
Put into operation

XPS-E 9 / 36
3.3 Parametrization
The parameterization data of XPS-E consists of 7 DP-Slave standard
bytes and 16 device-specific parameters bytes (User_Prm_data, ->
user_prm_len = 16). As user diagnostic data, 8 additional diagnostics
bytes are available. (diag_len = 8).
◦ For initialisation of XPS-E send a set_prm telegram. For this purpose,
use the parameters for PROFIBUS-DP and the serial interface
described in chapter 2.5.
◦ Check the parameterization with slave_diag.
◦ Then use the command chk_cfg to configure the XPS-E. Prior to that,
the configuration can be read with the command get_cfg from XPS-E. If
chk_cfg is executed directly after the initialization, the maximum
data_exchange telegram length is loaded from XPE-E. For shorter
data_exchange telegram length select one of the possible
configurations which are defined in the GSD file or select those
arbitrarily according to the PROFIBUS-DP standard.
ðAfter successful parameterization XPS-E is prepared for data exchange.
The Status/Run LED is now flashing green.
NOTICE You can verify the parametrization and configuration telegram by
means of slave_diag.
In the following, only those parameters are described that are required for
operating the XPS-E. For the significance of the remaining PROFIBUS- DP
standard parameters please refer to the standard EN50170 and the GSD
file.
Also see about this
2set_prm Parametrization [}10]
Put into operation

XPS-E 10 / 36
3.4 set_prm Parametrization
The Bytes 1-7 are PROFIBUS-DP standard parameters, Byte 8-23
are device- specific parameters (usr_prm).
Oktet Parameter Name Value
1 Station_status 0x80*
2 WD_fact_1 0x00
3 WD_fact_2 0x00
4 Min TSDR 55
5 Ident_Number [0] 0x95
6 Ident_Number [1] 0x10
7 Group_Ident 0x00
8..11 Reserved -
12 Baud Rate setting of serial interface See Table „Baud Rate of
Serial Interface“ [}10]
13 Character Transmission Mode of serial
interface
See Table „Character
Transmission Mode
“ [}10]
14 Handshake setting of serial interface See Table „Handshake-
Mode“ [}10]
15 XOFF-Timeout of serial interface See Section „Timeout Soft-
ware Handshake/Mod-
bus“ [}10]
16 Receive Mode of PROFIBUS interface See Table „Data Transmis-
sion Mode“ [}10]
17 Receive Mode of PROFIBUS interface See Table „Extended
Gateway configuration
data“ [}10]
18 Trigger character for serial triggered
mode
(usually LF (0x0A)
-
19..23 Reserved -
Table1: set_prm
*Sync_Req and Freeze_Req are not supported.
Put into operation
Indice
Altri manuali Kunbus Portale

Kunbus
Kunbus PROFINET IRT Slave Manuale utente

Kunbus
Kunbus FNL Series Manuale utente

Kunbus
Kunbus PR100069 Manuale utente

Kunbus
Kunbus PR100088 Manuale utente

Kunbus
Kunbus FNL Series Manuale utente

Kunbus
Kunbus PR100073 Manuale utente

Kunbus
Kunbus Sercos Series Manuale utente

Kunbus
Kunbus PR100066 Manuale utente

Kunbus
Kunbus PR100074 Manuale utente
Manuali Portale popolari di altre marche

LST
LST M500RFE-AS Manuale utente

Kinnex
Kinnex Media Gateway Manuale utente

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuale utente

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuale utente

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuale utente

Telsey
Telsey CPVA 500 - SIP Manuale utente