LeCroy 3377 Manuale utente

1
OPERATOR'S MANUAL
MODEL 3377
32 CHANNEL CAMAC TDC
Revised
January 1997
(ECO 1101)

2
Corporate Headquarters
700 Chestnut Ridge Road
Chestnut Ridge, New York 10977-6499
Tel: (914) 578-6013 Fax: (914) 578-5984
E-mail: [email protected]
Copyright© December 1997. LeCroy™ is a registered trademark of LeCroy
Corporation. All rights reserved. Information in this publication supersedes all
earlier versions. Specifications are subject to change.

3
CONDITIONS FOR
CE CONFORMITY Since this product is a subassembly, it is the responsibility of the end
user, acting as the system integrator, to ensure that the overall system is
CE compliant. This product was demonstrated to meet CE conformity
using a CE compliant crate housed in an EMI/RFI shielded enclosure. It
is strongly recommended that the system integrator establish these
same conditions.
CE CONFORMITY

5
COOLING It is imperative that the Model 3377 TDC be well cooled. Be sure fans
move sufficient air to maintain exhaust air temperature at less than
50°C.
INSTALLATION Crate power should be turned off during insertion or removal of modules
in accordance with the CAMAC specification.
SPECIFICATIONS The information contained in this manual is subject to change without
notice. The reference for product specification is the Technical Data
Sheet effective at the time of purchase.
ELECTROSTATIC
SENSITIVITY While measures have been taken to protect the MTD133 ASIC from
electrostatic damage, it is still imperative to follow anti-static procedures
when handling this CMOS device. Removal of the MTD133 from its
socket may void the warranty.
CAUTION

7
1. General Information
Purpose 9
Unpacking and Inspection 9
Warranty 9
Product Assistance 9
Maintenance Agreements 9
Documentation Discrepancies 10
Software Licensing Agreement 10
Service Procedure 10
2. Installation
General Installation 11
Cables 11
3. Product Description
Introduction 13
Product Description 13
Specifications 14
Front Panel 14
Displays 15
Inputs and Outputs 15
Control 15
Signal Inputs 16
ECLbus output 16
Rear Panel 16
Standard CAMAC Function Codes 16
4. Operating Instructions
Programming the Unit for a Different Mode of Operation 19
Operating Modes 20
Mode 0: Common Stop, Single Word Mode 21
Control Registers 21
Maximum Time Range 23
Offset 23
Dead Time 24
Front Panel Clear Input 24
Mode 1: Common Start, Single Word 25
Control Registers 25
Common Start Time Out 27
Dead Time 28
Front Panel Clear 28
Mode 2: Common Stop, double word 29
Control Registers 29
Maximum time range 31
Dead Time 31
Front Panel Clear Input 31
Mode 3: Common Start, Double Word Mode 32
Control Registers 32
Common Start Time out 34
Dead Time 34
Front Panel Clear 34
TABLE OF CONTENTS

8
Trigger Outputs 36
Trigger Outputs in the Common Stop Modes 36
Trigger Outputs in the Common Start Modes 37
Readout Modes and Data Formats 38
CAMAC 38
Buffered Mode 38
Unbuffered Mode 38
ECLPORT (FERA) Mode 38
Buffered Mode 38
Unbuffered Mode 38
FERA Compatibility 38
Standard 4300B FERA Behavior 38
Modified Model 3377 FERA Behavior 39
4300 Compatible Mode 39
Fast FERA Mode 40
Data Formats 40
Single Word Format 40
Double Word Format 40
Suppressing the Header 41
Example 3377 Programming Sequence 42
5. Theory of Operation
Time Measurements 43
Control and Readout 43
Event Buffer Memory 44
CAMAC Interface 44
ECL Port 44
Trigger Outputs 44
Support Circuits 44
6. Additional Information
Testing the Model 3377 45
Extending the Time Range 46
LabView™ Support 47
7. Index 49
LabView™ is a registered trademark of National Instruments Corporation.

9
PURPOSE This manual is intended to provide information regarding the installation
and operation of the LeCroy Model 3377 Time-to-Digital Converter.
UNPACKING AND
INSPECTION It is recommended that the shipment be thoroughly inspected immedi-
ately upon delivery. All material in the container should be checked
against the enclosed Packing List and shortages reported promptly.
If the shipment is damaged in any way, please notify the Customer
Service Department or the local field service office. If the damage is
due to mishandling during shipment, you may be requested to assist in
contacting the carrier in filing a damage claim.
WARRANTY LeCroy warrants its instrument products to operate within specifications
under normal use and service for a period of one year from the date of
shipment. Component products, replacement parts, and repairs are
warranted for 90 days. This warranty extends only to the originalpur-
chaser. Software is thoroughly tested, but is supplied “as is” with no
warranty of any kind covering detailed performance. Accessory products
not manufactured by LeCroy are covered by the original equipment
manufacturers’ warranty only.
In exercising this warranty, LeCroy will repair or, at its option, replace
any product returned to the Customer Service Department or an
authorized service facility within the warranty period, provided that the
warrantor’s examination discloses that the product is defective due to
workmanship or materials and has not been caused by misuse, neglect,
accident or abnormal conditions or operations.
The purchaser is responsible for the transportation and insurance
charges arising from the return of products to the servicing facility.
LeCroy will return all in-warranty products with transportation prepaid.
This warranty is in lieu of all other warranties, express or implied,
including but not limited to any implied warranty of merchantability,
fitness, or adequacy for any particular purpose or use. LeCroy shall not
be liable for any special, incidental, or consequential damages, whether
in contract, or otherwise.PRODUCT ASSISTANCE Answers to
questions concerning installation, calibration, and use of LeCroy equip-
ment are available from the Customer Service Department, 700 Chest-
nut Ridge Road, Chestnut Ridge, New York, 10977-6499, (914) 578-
6030.
MAINTENANCE
AGREEMENTS LeCroy offers a selection of customer support services. For example,
Maintenance Agreements provide extended warranty that allows the
customer to budget maintenance costs after the initial warranty has
expired. Other services such as installation, training, on-site repair, and
addition of engineering improvements are available through specific
Supplemental Support Agreements. Please contact the Customer
Service Department.
DOCUMENTATION
GENERAL INFORMATION

10
DISCREPANCIES LeCroy is committed to providing state-of-the-art instrumentation and is
continually refining and improving the performance of its products.
While physical modifications can be implemented quite rapidly, the
corrected documentation frequently requires more time to produce.
Consequently, this manual may not agree in every detail with the accom-
panying product and the schematics in the Service Documentation.
There may be small discrepancies in the values of components for the
purposes of pulse shape, timing, offset, etc., and, occasionally, minor
logic changes. Where any such inconsistencies exist, please be as-
sured that the unit is correct and incorporates the most up-to-date
circuitry.
SOFTWARE LICENSING
AGREEMENT Software products are licensed for a single machine. Under this license
you may:
■Copy the software for backup or modification purposes in support of
your use of the software on a single machine.
■Modify the software and/or merge it into another program for your
use on a single machine.
■Transfer the software and the license to another party if the other
party accepts the terms of this agreement and you relinquish all
copies, whether in printed or machine readable form, including all
modified or merged versions.
SERVICE PROCEDURE Products requiring maintenance should be returned to the Customer
Service Department or authorized service facility. If under warranty,
LeCroy will repair or replace the product at no charge. The purchaser is
only responsible for the transportation charges arising from return of the
goods to the service facility. For all LeCroy products in need of repair
after the warranty period, the customer must provide a Purchase Order
Number before any inoperative equipment can be repaired or replaced.
The customer will be billed for the parts and labor for the repair as well
as for shipping. All products returned for repair should be identified by
the model and serial numbers and include a description of the defect or
failure, name and phone number of the user. In the case of products
returned, a Return Authorization Number is required and may be ob-
tained by contacting the Customer Service Department.

11
GENERAL INSTALLATION The LeCroy Model 3377 TDC is intended for use within a standard
CAMAC crate, such as the LeCroy Model 8025 CAMAC Crate with
25 slot positions or the Model 8007A with 7 positions. The following
voltage sources must be properly connected to the backplane: +24 V,
+6 V, -6 V, and -24 V. Each crate must be controlled by either a slave or
intelligent controller. The controller must occupy the right-most slot in
the crate. Its purpose is to issue CAMAC commands to the modules
and transfer information between a computer (or other digital device)
and the CAMAC modules. LeCroy offers such crate controllers, includ-
ing the Model 8901A. The 8901A is a GPIB/CAMAC slave interface that
operates as a “Talker/Listener”, allowing the crate to act as one GPIB
instrument.
With the power off, the 3377 is inserted into one of the slots of the
CAMAC crate. The edge connector on the module should mate with the
bus connector with modest pressure. The thumb screw located on the
lower edge of the card should be engaged and tightened. Note the slot
number of the module, as it will later be used for addressing.
CABLES The 3377 is designed to use twisted pair cables for the input, output and
control signals, single twisted pair cables for the control inputs and 34
wire ribbon cable for the inputs and ECLbus output. Care should be
taken to install high quality cables to minimize the effects of noise and
crosstalk. There are two types of 34 conductor multiwire cables avail-
able, one for short connections using flat ribbon cable and one for longer
connections using twist and flat cable.
Suitable cables are available from LeCroy.
■STP-DC /02/L - single twisted pair cable for control signals.
■STC-DC /34/L - flat multiwire cable for short interconnections.
■LTC-DC /34-L or DC2 /34-L - twisted-pair multiwire cable for long
interconnection.
All signal inputs are differential ECL and have a balanced 120 ohm
termination.
INSTALLATION

13
INTRODUCTION The LeCroy CAMAC Model 3377 is a 32-channel Multihit Time-to-Digital
Converter (TDC) intended for high rate particle physics experiments.
The 500 picosecond digitizing resolution, 32 microsecond maximum full
scale, and low dead time make the Model 3377 suitable for a wide range
of applications. The Model 3377 can be operated either in Common
Start or Common Stop mode with up to 16 measurements (16 edge
measurements, leading edge only, or leading and trailing edge) recorded
on each channel. The full scale time range is programmable up to
32 microseconds. The eight trigger outputs are programmable, and can
be used in either first or second level triggers. The multi event buffer
allows up to 31 events to be recorded before readout. The readout is
either over the CAMAC dataway, or by a FERA™ compatible high speed
ECL port.
PRODUCT DESCRIPTION The 32 inputs are differential ECL, with a balanced 120 ohm termination.
Either the leading edge or both leading and trailing edge may be
recorded, with a double hit resolution of less than 10 nanoseconds. The
number of edge measurements recorded per channel is programmable
from 1 to 16.
The 3377 can be programmed to operate in either Common Start or
Common Stop mode with either single or double data word output
format.
The single word format packs 10 data bits (leading edge only, 9 bits if
both edges are recorded) into a 16 bit word, for low dead time drift
chamber applications. The programmable offset and resolution (500 ps
to 4 nsec LSB) allow the time range (255 nanoseconds to 4 microsec-
onds) to be placed as a window anywhere within the 32 microsecond full
scale.
The double word format preserves the full 16 bit time data for wide
dynamic range applications. The full scale time is programmable in
8 nsec steps up to 32.7 microseconds. The resolution is fixed at
500 picoseconds.
Eight dECL trigger outputs are provided at the rear panel. For trigger
purpose only, the input pulses are OR’ed together in groups of four (for
example: output 1 is the or channels 0, 1, 2, 3). In Common Stop
mode, the trigger outputs are programmable in width and delay, and can
be latched at the Stop time. In Common Start mode, the triggers are
latched.
The 3377 may be tested using an internal tester (Common Start mode
only). The number of pulses and the pulse duration are programmable.
At the end of acquisition (Common Stop or Common Start time out) the
data is unloaded from the MTD133s and stored in a multievent FIFO
buffer. The dead time is 1.8 microseconds plus 100 nsec per recorded
hit (200 nsec per hit when in double word mode).
The readout is by standard CAMAC or by the high speed ECL port. This
can occur in background, while the front end is recording data hits. A
PRODUCT DESCRIPTION
Indice
Altri manuali LeCroy Strumento di misura

LeCroy
LeCroy USB Protocol Suite Advisor T3 Manuale utente

LeCroy
LeCroy PP010-1 Manuale utente

LeCroy
LeCroy USB Mobile HS Manuale utente

LeCroy
LeCroy ZS1000 Manuale utente

LeCroy
LeCroy LogicStudio Manuale elenco delle parti

LeCroy
LeCroy DXC100A Manuale utente

LeCroy
LeCroy SDA Manuale utente

LeCroy
LeCroy Sierra M6-2 Manuale utente

LeCroy
LeCroy AP034 Manuale utente

LeCroy
LeCroy Advisor Manuale utente