Control System
Topics at a Glance
Installation.............See Installation Guide
User Interface ........................................7
Quick Start Configuration .....................10
Initial Setup ..........................................18
Detailed Operation ..............................44
Scene Recording .................................53
Scheduling...........................................62
System Layout Charts .........................68
WEB VERSION

WEB VERSION

Table of Contents
Configuration Guide
Leviton Dimensions 4000 Series Architectural Lighting Controller
Page 2
OVERVIEWQUICK STARTSETUPOPERATIONCONFIGURATION
Table of Contents .............................................................2
Warnings ..........................................................................4
Overview ..........................................................................5
Installation Recommendations .........................................6
Getting around the Interface .............................................7
Quick Start Configuration ................................................10
D4104, D4106, D4206..............................................11
D4006 .......................................................................13
D4200 .......................................................................14
Power Up Initialization ....................................................16
Setup ..............................................................................18
Accessing the Configuration Menus ........................19
Network Settings .......................................................20
The Patch ..................................................................23
Zone to Channel Patch ..............................................24
Dimmer to Circuit Patch .............................................27
Configuring Dimmers .................................................28
Devices with Dimmers Only (D4006) .........................33
Miscellaneous Settings Menu ....................................35
Personalities ..............................................................41
Connecting Entrance Stations ...................................42
Operation .......................................................................44
Overview of Unit Controls ........................................44
Configure the Clock ...................................................52
Recording a Scene .....................................................53
Changing the MAX and OFF Lighting Levels ..............55
Zone Labels: Naming a Scene or Zone .......................55
Preventing Changes - LOCKS ....................................58
Scheduled Events ......................................................62
Viewing Scheduled Events .........................................64
Sequencer ..................................................................64
System Layout Charts ....................................................68
Latitude & Longitude Chart ............................................74
WEB VERSION

Page 3
WEB VERSION

Warnings
Configuration Guide
Leviton Dimensions 4000 Series Architectural Lighting Controller
Page 4
1: TO AVOID FIRE, SHOCK OR DEATH: TURN OFF
POWER AT MAIN CIRCUIT BREAKER OR FUSE AND
TEST THAT THE POWER IS OFF BEFORE WIRING!
2: To be installed and/or used in accordance with
appropriate electrical codes and regulations.
3: To be installed by an Electrician.
4: DO NOT CONNECT line voltage wires to low
voltage terminals.
5: For longest lamp life, most lamp manufacturers
recommend their fluorescent lamps should be operated
at full brightness for a minimum of 100 hours before
dimming is permitted.
6: For best results, lamp brands and types should not be
intermixed on a circuit.
7: Disconnect power when servicing the dimmer, fixture or
when changing lamps.
8: All devices in the D4000 system are rated for Indoor
use only.
9: Test all circuits for any fault before connecting to this
device. Damage to this device due to any fault at the load
or line side is not covered by this products warranty.
10: Know the connected load type.
11: DO NOT connect load types for which the device
is not rated.
OVERVIEWQUICK STARTSETUPOPERATIONCONFIGURATION
WEB VERSION

Overview
This guide is split into several sections:
•Overview - Overview of manual, key topics, and device
navigation.
•Quick Start - Critical steps for getting up and running
quickly.
•Setup - In-depth topics required for proper initial setup.
•Operation - How to operate your device and the features of
the user interface.
•Configuration - Detailed configuration information
Accompanying this guide should be an installation guide covering
all the connections and other requirements of proper installation.
Common Topics
•How to operate the device, see page 44.
•Power Up Initialization, see page 16.
•How to configure a dimmer for a fluorescent (or any other
load type,) see page 28.
•How to set the starting network channel, see page 25.
•How to record a scene, see page 49.
•How to set the date and time, see page 52.
•How to prevent changes to the device, see page 58.
•How to trigger a scene at a specific time of day see page 62.
Page 5
WEB VERSION

Configuration Guide
Installation Recommendations
Leviton Dimensions 4000 Series Architectural Lighting Controller
Page 6
For best results using the Dimension 4000 Architectural
Lighting Controllers, follow these recommendations:
1: Plan the system before beginning the installation:
• Device location and primary purpose.
• Determine which controllers are controlling which
dimmers.
• Determine location and function of remote stations.
• Consider power supply, wire size, run length, load
requirements.
• Consider any regularly scheduled events.
2: Follow the installation instructions covering physical
installation, connections and wring of your device.
3: Use the information in this “setup” section of this guide
for initial setup, and the “configuration” section for regular
programming.
4: When configuring a system with multiple devices it’s
helpful to connect them one at a time so that any
problems are isolated as they arise. For example:
• First install & configure master stations.
• Confirm that the master station is working correctly.
• Install first entry station (or device), configure it, and
confirm that it’s working correctly.
• Repeat until all device are installed.
OVERVIEWQUICK STARTSETUPOPERATIONCONFIGURATION
WEB VERSION

19 2
10
3
11
4
12
5
13
6
14
7
15
8
16
Previous Field or
Change Scene Blank
Shortcut
Scene
Programming or
llaceR
Select Option and Save
nottuBlecnaCdnauneM
2-Line, 16-Character LCD
Next Field or
Change Scene Bank
Shortcut
Master
Page
Zones
Clear
Change Zone
Clear
IR Receiver
Master
Dim/Bright
Zone
Information
Display
Zone
Dim/Bright
All Zones to
ssenthgirBmumixaM
All Off
Previous/Next
Menu Option
Select
Save
Menu
Cancel
Off Button
Max Button
nottuBenecS
1 3 9 02 4 5 6 7 8
MAX. OFF
Getting around the Interface
A full discussion of how to operate your device is covered in the
section titled “Operation” on page 44. We recommend that you
review this information in its entirety. Contained in this section is
a only a brief overview to the topic.
Figure 15 - D4200 Buttons
Controls
With the cover closed, you can access the first eight SCENE
buttons and the MAX and OFF buttons.
Page 7
WEB VERSION

Figure 14 - Scene, MAX and OFF button Locations
• SCENES 1-8. Selects a new Scene, and causes a pre-
programmed set of lighting levels to fade in while the
previously selected Scene fades out.
• MAX. By default raises all zones to full.
• OFF. By default, raises all zones to zero output.
With the cover open, you can also access the LCD display, the
Master Up and Down buttons, the individual Zone Up
and Down buttons, the Zone identification and status
buttons, the Zone level indicators, and the programming/
navigation buttons.
Navigating Menus
To navigate the menus, use the programming/navigation
buttons:
Configuration Guide
Select
Save
Menu
Cancel Clear
Leviton Dimensions 4000 Series Architectural Lighting Controller
Page
Zones
Page 8
• Left and Right . Moves the cursor back and
forth, or to the previous or next item.
• Up and Down . Scrolls through menus and
submenus; changes selected values.
• Select/Save. Selects a value to be modified; saves the
modified value.
• Menu/Cancel. Enters menu mode; exits submenus;
exits menu mode.
• Clear. Clears or returns a selected value to zero.
• Page Zones. Alternates the Zone numbers between 1-8
and 9-16, 17-24 and 25-32. The LCD will indicate which
Page you are currently in. P1 refers to Zones 1-8, P2
Figure 11 - Programming Buttons
OVERVIEWQUICK STARTSETUPOPERATIONCONFIGURATION
WEB VERSION

Scene Name
Breakfast P1
S01 TUE 04:29p LE
Scene # Days of week
Page 9
indicates Zone 9-16, P3 indicates Zone 17-24 and
P4 indicates Zones 25-32 are active.
Page Number - P1 = Zones 1-8
P2 = Zones 9-16
P3 = Zones 17-24
P4 = Zones 25-32
Indicates Schedule is active
Indicates Station is Locked
The Zone number LED’s do not light up on
P3 or P4
WEB VERSION
Questo manuale è adatto per i seguenti modelli
4
Indice
Altri manuali Leviton Sistema di controllo

Leviton
Leviton Lumina LU20S-DNW Manuale utente

Leviton
Leviton 48211-AVC Manuale utente

Leviton
Leviton DMX-512 Manuale utente

Leviton
Leviton D4200 Manuale utente

Leviton
Leviton Decora DZR15 Manuale utente

Leviton
Leviton DOS05 Manuale utente

Leviton
Leviton DOS05 Manuale utente

Leviton
Leviton Dimensions D3200 Guida utente

Leviton
Leviton 600 Series Manuale utente