LineEye LE-8500X-RT Manuale utente

OPTIONAL KIT
FOR MULTI PROTOCOL ANALYZER
LE-8500X-RT/LE-8500XR-RT
PC Link Software
LE-PC800X
Instruction Manual
The 1th Edition
The CD-ROM attached contains the English and Japanese instruction manuals in PDF format.
The actual display or manner of operation may differ from that of the instruction manual
because of the improvement of the product and so on. Please refer to the online help also for
the use of the software.

Contents
Chapter 1 Before Using the Product ....................................................................................................1
Chapter 2 Introduction ..........................................................................................................................2
General Description ............................................................................................................................................................ 2
Unpacking ........................................................................................................................................................................... 2
Chapter 3 Before Start-up .....................................................................................................................3
USB Driver Installation ...................................................................................................................................................... 3
Conrm the IP address of analyzer. .................................................................................................................................... 3
Installation Guide................................................................................................................................................................ 4
Uninstallation Guide ........................................................................................................................................................... 4
Chapter 4 Data Window......................................................................................................................5
Data Window of PC link software ...................................................................................................................................... 5
Chapter 5 Environment Setting............................................................................................................ 7
Remote Setting.................................................................................................................................................................. 7
Chapter 6 Remote Monitor ................................................................................................................12
Connection ........................................................................................................................................................................ 12
Analyzer Setting................................................................................................................................................................ 12
Simulation Data Setting .................................................................................................................................................... 13
Max speed when remote monitoring................................................................................................................................. 14
Start Measurement ............................................................................................................................................................ 14
Stop Measurement............................................................................................................................................................. 14
Remote Monitor Screen .................................................................................................................................................... 15
Read the Measurement Data ............................................................................................................................................. 16
Search Data ....................................................................................................................................................................... 16
Chapter 7 Bit Error Rate Test (BERT) ...............................................................................................17
Start Measurement ............................................................................................................................................................ 17
Chapter 8 Key Emulation...................................................................................................................18
Run Key Emulation........................................................................................................................................................... 18
Capture the Screen Image ................................................................................................................................................. 18
Chapter 9 Text Conversion ................................................................................................................19
Text Conversion Function Setting..................................................................................................................................... 19
Start Text Conversion........................................................................................................................................................ 21
Chapter 10 Waveform Monitor Data..................................................................................................22
Chapter 11 Connecting Multiple Analyzers.......................................................................................23
Add the Remote Setting .................................................................................................................................................... 23
Open the Data Window..................................................................................................................................................... 24
Delete the Remote Setting................................................................................................................................................. 24
Operate Setting When Starting.......................................................................................................................................... 24
Startup Options ................................................................................................................................................................. 25
Chapter 12 Specication....................................................................................................................26
Copyright 2008-2020 by LINEEYE CO., LTD. All rights reserved.

-1-
Chapter 1 Before Using the Product
Software License Agreement
LINEEYE CO., LTD (LINEEYE) grants you to use the software program and the documents under the terms of
this license. And you are consenting to be bound by and are becoming a party to this agreement.
To use the software, you need to agree to this license agreement.
1. Copyright
LINEEYE holds the copyright on this software.
2. Grant of License
LINEEYE grants for you to use this software on only one computer by agreeing this license agreement. There-
fore, you shall not rent, lease and loan to a third party.
3. Copy, Analysis, Modication
This software must not be reproduced, analyzed or modied in any form unless prescribed in the manual.
4. Upgrade
This software may be upgraded without any advance notice because of technical progress of hardware or soft-
ware. LINEEYE provides the upgraded software with the upgrade fee. For upgrade, only licensed user can have
upgrades.
5. Limitation of Liability
In no event shall LINEEYE or its licensors be liable for any loss of business or profits, or for any
direct,indirect, incidental or consequential damages arising from products of this software or the related soft-
ware. Besides LINEEYE shall not be liable damages arising from the equipment.
6. General
If any provision of the agreement is held invalid, such provision shall be removed from this license agreement.
7. Support
LINEEYE supports functions, operation and only the problem on this software.
8. Notice
Any matter not specied in this agreement will be governed by and constructed in accordance with copy right
law and related laws.
LINEEYE CO., LTD

-2-
Chapter 2 Introduction
Thank you for your purchase of LINEEYE’s PC link software.
●To use it correctly, you are advised to read and understand this together with the instruction manual for
analyzer thoroughly.
●Keep this instruction manual.
General Description
LE-PC800X is software to remotely control the protocol analyzer from a PC and utilize the measurement
data on the PC.
Unpacking
When you unpack the product (the full edition), make sure that the followings are included. (The light edi-
tion of the software is included in the CD-ROM attached to the analyzer.)
□ CD-ROM (software) 1
□ Instruction Manual (This book) 1
□ User Registration Card 1
Please contact your LINEEYE distributors if you nd any damage to the product caused by trans-
portation, or if there are accessories lacking.
Applicable Analyzer
LE-8500X-RT, LE-8500XR-RT,
LE-8500X(R)/LE-8600X(R) equipped with SB-R2TS1.

-3-
Chapter 3 Before Start-up
USB Driver Installation
When using this software by USB connection, connect the USB port of PC and analyzer using the
USB cable before using it.
Conrm the IP address of analyzer.
When using this software by LAN or Wi-Fi (appropriate model only), conrm the IP address and port
number of analyzer before using it.
Please refer to the instruction manual of analyzer. (Refer to “Network” on “System setting”)

-4-
Installation Guide
1. Execute “setup.exe” in the attached CD.
If the PC (to which you want to install the software) does not have a CD-ROM drive, copy it
to a storage device such as USB ash using another PC which has a CD-ROM drive to bring
it to the PC and execute it.
2. First, click “Yes” in the “User Account Control” display.
3. When the Windows rewall displays a message such as “Windows protected your PC”, click “Detail”-
“Run” to run the program.
4. Even if the virus security software displays a message that blocks this software, click the option to
run the software such as “Run this program” to cancel the blocking.
5. When the installer starts up, proceed according to the instructions on the screen. You will be prompt-
ed for the serial number during installation.
Please enter the serial number of this software written on the attached user registration card.
For the light version “LE-PC800X (LITE)” which you can download free of charge from the
LINEEYE website, the serial number will be automatically entered as “LITE”.
6. When the installation completion message is displayed, click “Finish”.
Uninstallation Guide
1. Open “Uninstall or change a program” (or “Program and Features”) from the control panel. (Or
right-click on “LE-PC800X” in the start menu and select “uninstall”.)
2. Select “LE-PC800X” from the list and execute “Uninstall and change”.
3. First, click “Yes” in the “User Accounts” display.
4. Click “OK” at the deletion conrmation display.
When the light version “LE-PC800X (LITE)” is already installed in the PC, uninstall the
light version before installing the full version.
When updating the product version (full edition), you can install the new version without
uninstalling the old version. By doing so, the product serial number etc. will be carried over.

-5-
Chapter 4 Data Window
Data Window of PC link software
■Starting the PC link software.
Start "LE-PC800X" from the "Start" of Windows.
Usually, the following display will appear.
1) →
2) →
3) →
Data Window
4)
↑
5)
↑
6)
↑
7)
↑
1) Menu
Can perform various operations.
2) Tool Bar
Can perform various operations.
3) Data display part
Displays the measured data.

-6-
4) Data position display part
Displays the data position in the Data display part. The number of data loss is displayed while
remote monitoring.
5) Various state display part
Displays such as the measurement state.
6) Connection state display part
Displays the remote connection state between LE-PC800X and your analyzer.
7) Model name display part
Displays the model name of your analyzer being set at the time of oine, and one of your analyzer
being connected at the time of online.
* For LE-8500X-RT, “LE-8500X+SB-R2TS1” is displayed.
For LE-8500XR-RT, “LE-8500XR+SB-R2TS1” is displayed.
Refer to the "On-Line Help" for more details of operation.

-7-
Chapter 5 Environment Setting
Remote Setting
Click on the tool bar of the data window (or “Remote Setting” of “Remote” menu) to set the remote
setting.
The remote setting consists of “Connection”, “Model selection”, “Key emulation” and “Miscellaneous”.
■ Connection
Sets the remote connection
“Connection Method”
“USB”
Connect via USB port.
(Select the serial number of analyzer which you wish to connect.)
“LAN/Wi-Fi(TCP/IP)”
Input the IP address (or host name) of analyzer to “host name”, and the port number of
analyzer to “data port”.

-8-
■Model selection
Sets your analyzer settings. Mainly, it is used at the time of oine. However in the case of that there is
information which is not received by remote communication at the time of online, it is used as it is set.
In addition. if the information is received by remote communication, these settings are automatically
changed.
“Analyzer model”
Selects the model name of the target analyzer.
“Expansion board”
The expansion board which is equipped with the analyzer is displayed.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali LineEye Strumento di misura

LineEye
LineEye LE-8600XR Manuale utente

LineEye
LineEye LE-580FX Manuale utente

LineEye
LineEye LE-8500XR-RT Manuale utente

LineEye
LineEye LE-8600X Manuale utente

LineEye
LineEye LE-8500XR Manuale utente

LineEye
LineEye LE-8500X Manuale utente

LineEye
LineEye LE Series Manuale utente

LineEye
LineEye LE Series Manuale utente

LineEye
LineEye LE-650H2 Manuale utente

LineEye
LineEye LE-110SA Manuale utente