Lutz ST10 Manuale utente

Translation of the
original instructions
BASIC FLOW METER
Type
ST10
SL10
LM10
UN10
VA10
HC10
HDO080
HDO120
HDO200
HDO250P
HDO250
HDO400
HDO500
Read this operating instructions before start up!
To be retained for future reference.
en

2
0698-601 Basic ow meter - 04/19
en
Table of Contents
A. General ............................................................................................................................................ 4
1. Concerning this manual.............................................................................................................. 4
1.1 Terms .................................................................................................................................. 4
1.2 Target groups...................................................................................................................... 4
1.3 Associated applicable documents....................................................................................... 4
1.4 Warnings and symbols ....................................................................................................... 5
1.5 Latest state.......................................................................................................................... 5
1.6 Copyright ............................................................................................................................ 5
2. Safety .................................................................................................................................. 6
2.1 General safety information................................................................................................. 6
3. Transport and storage................................................................................................................. 7
3.1 Transport............................................................................................................................. 7
3.2 Storage................................................................................................................................ 7
4. Year of construction .................................................................................................................... 7
5. Modular Flow Meter System TS................................................................................................... 8
6. Modular Flow Meter System HDO............................................................................................... 9
B. BasicowmeterTS......................................................................................................................... 10
1. Proper use ................................................................................................................................ 10
1.1 Application in explosion hazard areas .............................................................................. 10
1.2 Technical data ................................................................................................................... 11
1.3 Maximum pressure depending on temperature of the medium...................................... 12
1.4 Complete hose system...................................................................................................... 12
1.5 Pressure surges (water hammer) ..................................................................................... 12
1.6 Pressure drop.................................................................................................................... 13
1.7 Accuracyofmeasurementandowrate .......................................................................... 14
1.8 Liability.............................................................................................................................. 15
2. Prevention of obvious misapplication....................................................................................... 15
3. Installation ................................................................................................................................ 16
3.1 Connection for drum pump operation ............................................................................. 16
3.2 Connection to the piping system – Flange connection..................................................... 17
3.3 Valve connection............................................................................................................... 18
4. Maintenance and servicing....................................................................................................... 18
4.1 Cleaningthelterandcheckvalve................................................................................... 18
4.2 Dismantlingthebasicowmeter..................................................................................... 19

3
0698-601 Basic ow meter - 04/19
en
C. BasicowmeterHDO..................................................................................................................... 20
1. Proper use ................................................................................................................................ 20
1.1 Application in explosion hazard areas .............................................................................. 21
1.2 Technical data ................................................................................................................... 22
1.3 Liability.............................................................................................................................. 28
2. Installation ................................................................................................................................ 29
2.1 Electrical connection HDO080........................................................................................... 30
2.2 Drum pump connection.................................................................................................... 30
3. Operation ................................................................................................................................ 31
4. Disassembly and reassembly .................................................................................................... 31
4.1 BasicowmeterHDO250P............................................................................................... 31
4.1.1 Disassembly ............................................................................................................ 31
4.1.2 Reassembly ............................................................................................................. 32
4.2 BasicowmeterHDO120,HDO200,HDO250,HDO400andHDO500.............................. 33
4.2.1 Disassembly of wet ends ........................................................................................ 33
4.2.2 Assembly of wet ends.............................................................................................. 33
4.2.3 Reed switch board................................................................................................... 34
4.3 BasicowmeterHDO080 ................................................................................................. 35
4.3.1 Disassembly ............................................................................................................ 35
4.3.2 Reassembly ............................................................................................................. 35
D. Repairs .......................................................................................................................................... 36
E. Traceability...................................................................................................................................... 36
F. Waste disposal................................................................................................................................ 36
G. Annex .......................................................................................................................................... 37
1. Terminal assignment of cables and connectors........................................................................ 37
2. Trouble shooting ....................................................................................................................... 38
2.1 Fault report ....................................................................................................................... 38
2.2 Other faults....................................................................................................................... 40
SparepartslistbasicowmeterTS................................................................................................. 42-47
SparepartslistbasicowmeterHDO080............................................................................................ 48
SparepartslistbasicowmeterHDO250P..................................................................................... 49-50
SparepartslistbasicowmeterHDO120,200,250,400,500........................................................ 51-54
Declaration of Conformity .................................................................................................................... 55

4
0698-601 Basic ow meter - 04/19
en
A. General
1. Concerning this manual
This manual
• is part of this product
• is valid for all mentioned series
• describes the safe and proper use in all operating stages
1.1 Terms
User: Singlepersonororganisationwhoisusingtheproductse.g.customer,user,assistant
1.2 Target groups
Target group Task
User ►Retain these operating instructions at the product’s place of use for
future reference.
►Demandthestatoreadandobservetheseinstructionsandthe
additionalvaliddocuments,inparticularthesafetyinformationand
warnings.
►Observe additional regulations and instructions concerning the plant.
Qualiedpersonnel,installer ►Read,observeandfollowtheseinstructionsandtheadditionalvalid
documents,inparticularthesafetyinformationandwarnings.
Tab.1:Targetgroupsandtheirtasks
1.3 Associated applicable documents
Document Purpose
Operating instructions opera-
ting unit
Safeandproperuseoftheoperatingunit.Setupandcheckthefunctions
of the communication module.
Operating instructions relay
module
Safe and proper use of the relay module.
Operating instructions
communication module
Safe and proper use of the communication module.
Supplementary operating
instructions
for additional delivered components
Tab. 2: Associated applicable documents and purpose

5
0698-601 Basic ow meter - 04/19
en
1.4 Warnings and symbols
Warning Level of risk Consequences in case of
non-compliance
DANGER direct danger death or serious injury
WARNING possible direct danger death or serious injury
CAUTION possible dangerous situation light injury
NOTICE possible dangerous situation damage of property
Tab. 3: Warnings and consequences in case of non-compliance
Symbol Meaning
Safety information
► Complywithallmeasuresthataremarkedwithasafetysigntopreventinjuriesor
death.
iInformation / Recommendation
►What to do
→cross reference
3Requirement
Tab. 4: Symbols and meaning
1.5 Latest state
Pleasendthelateststateofthisoperatinginstructionunderwww.lutz-pumpen.de.
1.6 Copyright
The contents of these operating instructions and the images contained in them are subject to the copyright
protection of Lutz Pumpen GmbH.

6
0698-601 Basic ow meter - 04/19
en
2. Safety
The manufacturer will not be held responsible for any damages resulting from non-compliance of the
overalldocumentation,inparticularfordamagesincaseofnon-complianceoftheoperatinginstructions.
2.1 General safety information
Observe following regulations before accomplishing all activities.
Product safety
Thebasicowmeterisconstructedinconformitywiththestateoftheartandapprovedsafety-related
standards. Danger however can occur during use for life and health of the user or third parties or dama-
geofthebasicowmeterandothermaterialassets.Therefore:
• Operatethebasicowmeteronlyinatechnicallysoundstate,foritsproperuse,andconsciousof
safetyandhazardstakingintoaccounttheseinstructions.
• Ensurethattheseinstructionsandallassociatedapplicabledocumentsarecomplete,legible,and
stored in a place that personnel can access at all times.
• Refrainfromanymannerofworkingthatendangerspersonneloruninvolvedthirdparties.
• Inthecaseofasafety-relevantmalfunction,stoptheowmetersystemimmediatelyandenlista
responsible person to rectify the malfunction.
• Inadditiontotheoveralldocumentation,observethestatutoryorothersafetyandaccidentpreventi-
onregulations,aswellasthevalidstandardsandguidelinesoftherespectiveoperatingcountry.
Modications
Unlessthemanufacturerhasprovideditsconsentinwriting,themanufacturerisnotliableforinterven-
tionsperformedbytheuser(modications)ontheproduct,suchasconversion,alteration,newdesign,
etc.Modicationsnotagreedwiththemanufacturermayhavethefollowingeects,amongothers:
• Functional impairments on the appliance or plant
• Damage to the appliance and other property damage
• Environmental damage
• Personal injuries right through to death
Duties of the operator
Safety-conscious working
• Operatethebasicowmeteronlyinatechnicallysoundstate,foritsproperuse,andconsciousofsafety
andhazardstakingintoaccounttheseinstructions.
• Ensure observance and monitoring of:
- Proper use
- Statutory or other safety and accident prevention regulations
- Safety provisions in handling hazardous substances
- Valid standards and guidelines in the respective country of operation
• Provide protective equipment.

7
0698-601 Basic ow meter - 04/19
en
Personnel qualication
• Ensurethatpersonneltaskedwithworkonthebasicowmeterhavereadandunderstoodthese
instructionsandallassociatedapplicabledocuments,particularlysafety,maintenanceandservicing
information,beforetheystartwork.
• Clarifyresponsibilities,competenciesandmonitoringofthepersonnel.
• Ensurethatallworkiscarriedoutbytechnicalqualiedpersonnelonly:
- Assembly,servicing,maintenancework
- Workontheelectrics
Statutory warranty
• Duringtheguaranteeperiod,obtainthemanufacturer'spermissionformodications,maintenance
workoralteration.
• Use only original parts.
Duties of the personnel
• Observethenoticesonthebasicowmeterandmaintaintheminalegiblestate.
• Use protective equipment where necessary.
• Ensurethatthebasicowmeterisdisconnectedbeforeyoucarryoutassemblyandmaintenancework.
3. Transport and storage
3.1 Transport
Unpackingandcheckofconditionondelivery
►Unpackthebasicowmeteronreceiptandcheckfortransportdamages.
►Report transport damage to the manufacturer immediately.
►Checkthattheconsignmentiscompleteasordered.
3.2 Storage
NOTICE
Damage of property as a result of incorrect storage!
►Storebasicowmetercorrectly.
►StorebasicowmeterprotectedagainstweathereectsandUV-rays.
4. Year of construction
Theyearofconstructionoftheappliancecanbeseenontheeldfortheserialnumber.Hereareattached
totheserialnumberthebothlastdigitsoftheyearofconstruction,e.g.(-10fortheyear2010).

8
0698-601 Basic ow meter - 04/19
en
5. Modular Flow Meter System TS
Theowmeteroperatesaccordingtothepositivedisplacementprinciple.Inahousingttedwithinletand
outletisameasuringchamberthroughwhichtheuidisforcedtoowonitswaythroughthehousing.
Inthemeasuringchamber,anutatingdiscblockstheuid`sclearpath.Asitowsthroughthemeasuring
chamber,theuidpushesthenutatingdisctooneside.Itistheactionofdisplacingtheimpedimentwhich
produces the wobble movement of the disc and circular motion of the nutating disc shaft. By means of a
driver,amagnetwithseveralpolesissetintorotation,whichisabletoactivateamagneticallyswitched
contact through the lid of the housing. Every revolution of the nutating disc is assigned to a constant volume
andaxednumberofpulses,sopermittingtheelectonicevaluatingsystemtodeterminethevolumetric
owthroughthenumberofreceivedpulses.
For practically-orientated application, the ow meter system is made up of various modules:
ÀOperating unit
Electronicevaluatingunitwithtouchscreenforoperationoftheow
meter.
ÁProtection cap
Protectsthemodulesbasicowmeter,relaymoduleormainsunit
when the operating unit is decentrally installed.
Pulse converter
Ampliesthesignalsfromthebasicowmeter.Isrequiredifthe
signals need to be transmitted further than 5 m.
ÂRelay module
Switches the external electrical appliances such as pump motor and
solenoid valve and is controlled by the evaluating electronics of the
operating unit.
Mains unit
Supplies power to the operating unit when battery-powered operation
is not desired and when no relay module is needed.
Communication module
Istheinterfacetoothermanagement,controlorprocesscontrol
systemswithdierentinputsandoutputs.
à Basic ow meter
Housing and measuring chamber with all components for volumetric
measurement which come into contact with the transported medium.
The ow meter can be used in two dierent operating modes:
Manual mode: Forllingusingamanuallyoperatednozzle.The
part volume meter is reset to zero and the requi-
red volume is metered while the nozzle is being
operated.
Volume preset: Thepreselectedvolumeislledbypressingakey.
Volume preset is possible only when relay module
is connected.
Fig.1-Operatingunitandowmeter
Fig. 2 - Relay module and protection cap

9
0698-601 Basic ow meter - 04/19
en
Fig.3-Operatingunitandowmeter
Fig. 4 - Relay module and protection
cap
6. Modular Flow Meter System HDO
TheHDOseriesowmeterhasincorporatedtheovalgearprincipleintoitsdesign.Thishasprovento
beareliableandhighlyaccuratemethodofmeasuringow.Exceptionalrepeatabilityandhighaccuracy
overawiderangeofuidviscositiesandowratesarefeaturesoftheHDOseriesowmeterdesign.The
lowpressuredropandhighpressureratingmeanstheHDOseriesowmeterissuitableforbothgravity
and pump (in line) applications.
For practically-orientated application, the ow meter system is made up of various modules:
ÀOperating unit
Electronicevaluatingunitwithtouchscreenforoperationoftheow
meter.
ÁProtection cap
Protectsthemodulesbasicowmeter,relaymoduleormainsunit
when the operating unit is decentrally installed.
Pulse converter
Ampliesthesignalsfromthebasicowmeter.Isrequiredifthe
signals need to be transmitted further than 5 m.
ÂRelay module
Switches the external electrical appliances such as pump motor and
solenoid valve and is controlled by the evaluating electronics of the
operating unit.
Mains unit
Supplies power to the operating unit when battery-powered operation
is not desired and when no relay module is needed.
Communication module
Istheinterfacetoothermanagement,controlorprocesscontrol
systemswithdierentinputsandoutputs.
à Basic ow meter
Housing and measuring chamber with all components for volumetric
measurement which come into contact with the transported medium.
The ow meter can be used in two dierent operating modes:
Manual mode: Forllingusingamanuallyoperatednozzle.The
part volume meter is reset to zero and the requi-
red volume is metered while the nozzle is being
operated.
Volume preset: Thepreselectedvolumeislledbypressingakey.
Volume preset is possible only when relay module
is connected.

10
0698-601 Basic ow meter - 04/19
en
B. Basic ow meter TS
1. Proper use
Thebasicowmeterisusedformeasuringliquidvolumeswheregaugingmeteringisnotrequired.The
basicowmeterisprecalibratedfortheuseofwater.Themeasurementofotherpuremediaisalsopossible.
Todothis,adierentuser-speciccalibrationfactorisenteredattheoperatingunit.
NOTICE
These causes may impair the measurement result, damage the ow meter, or reduce its service life:
►stronglypulsatingow
►airbubblesintheow
►excessivelyloworhighowrate
►excessiveviscosityofthemeasureduid
►blowing through of compressed air.
1.1 Application in explosion hazard areas
!WARNING
Application in explosion hazard areas or the metering of ammable liquids can cause explosion
resulting in severe injury or death.
►Basicowmetersarenon-electricaloperatingappliancesnotrequiringocialapprovalwhenusedin
zone 1.
►ThebasicowmetersVA10,HC10,LM10andUN10correspondtothedirective2014/34/EU(groupII,
category2,forgasesandtemperatureclassT4).
►Thebasicowmetermayonlybeusedatatmosphericalconditionsof0.8barupto1.1baranda
temperaturerangeof-20°Cupto+40°C.Anapplicationisnotallowedinatmosphereswithammable
dust.
►ThetemperatureoftheliquidbeingpumpedislimitedfortypesLM10andUN10tomax.60°Candfor
types VA10 and HC10 to max. 80°C.
►Anequipotentialbondingmustbeestablishedbetweenbasicowmeter,pumptubeandhose-orpipe
line.
►Use only conductive pressure hoses or conductive pipes.
►Forapplicationswithadrumpumpthebasicowmetermustbemountedoutsideofthecontainer.
►Theadmissibleoperatingpressure(typesLM10andUN10-4bar,VA10andHC10-10bar)mustnot
be exceeded.
►In case another electronical device for analyzing is used than that provided by the manufacturer the
explosion protection regulations must be observed.
►Inordertoavoidresparkling,assemblyworksmustbecarriedoutbyqualiedpersonnelonly.
►Topreventcorrosionitmustbeensuredthatthebasicowmeterisresistanttotheliquidsbeing
transferred.
►Topreventanexplosivegasatmosphereinthebasicowmeteruseasolidhosesystem.
Questo manuale è adatto per i seguenti modelli
12
Indice
Altri manuali Lutz Strumento di misura