Mect MPCIB396 P6 Series Manuale utente

ME3025_13
03/21
USER’S MANUAL
Series MPCIB396 P6
(Bidirectional counter)


MPCIB 396 P6 mect s.r.l.
ME3025_13 03/21 3
INDEX
INDEX........................................................................................................................... 3
1.0 OVERVIEW................................................................................................... 5
1.1 TECHNICAL FEATURES.................................................................................. 5
1.2 DISPLAY MESSAGES ....................................................................................... 6
1.3 WIRING DIAGRAMS...................................................................................... 6
1.4 WIRING SCHEMATICS.................................................................................. 7
1.5 NPN or PNP INPUTS CONFIGURATION ..................................................... 8
1.6 PROGRAMMING TIPS ................................................................................... 9
1.7 BASE INSTRUMENT MENU DIAGRAM...................................................10
1.8 OPTIONS MENU DIAGRAM ....................................................................... 11
2.0 INSTALLATION REMARKS.................................................................... 12
2.1 INSTALLATION PROCEDURE......................................................................12
2.2 "nUnEr" and “dEnon” FUNCTION (multiplying factor)................................ 15
2.3 FRONT KEYS ENABLING.............................................................................. 16
2.4 TERMINALS 18 AND 19 CONFIGURATION ............................................... 17
2.5 “CoEnC” FUNCTION (encoder counting)........................................................18
2.6 “ PrESEt” FUNCTION (preset) ......................................................................... 19
2.7 DEFAULT PARAMETERS (dEF)....................................................................19
2.8 TOTAL COUNTING FUNCTION.................................................................... 19
2.9 MONODIRECTIONAL PULSE COUNTER FUNCTIONING ....................... 20
2.10 A + B AND A –B FUNCTIONING............................................................. 20
2.11 MARKER PULSE FUNCTIONING ...............................................................20
3.0 ALARMS (option)....................................................................................... 20
3.1 ALARM SETTING............................................................................................ 22
4.0 ANALOGUE OUTPUTS (option)...............................................................26
4.1 TECHNICAL CHARACTERISTICS................................................................ 26
4.2 INSTALLATION OF ANALOGUE OUTPUT................................................. 26
4.3 NOTES ON THE SET UP OF ANALOGUE OUTPUTS.................................29
5.0 SERIAL OUTPUT (option) ....................................................................... 30
5.1 DATA READING FROM HOST TO INSTRUMENT MPCIB396 P6............33
5.2 DATA TRANSMISSION FROM MPCIB396 P6 TO HOST..........................33
5.3 DATA WRITING FROM HOST TO MPCIB396 P6........................................ 34
5.4 COMMAND CODES.........................................................................................35
5.5 TRANSMISSION OF HEXADECIMAL VALUES......................................... 36
5.6 ALARM SETTING (W status word)................................................................. 37
5.7 AR STATUS WORD ......................................................................................... 38

MPCIB 396 P6 mect s.r.l.
ME3025_13 03/21 4
5.8 BASIC PROGRAM............................................................................................39
6.0 PASSWORD FUNCTION..........................................................................40
7.0 SET UP........................................................................................................41
!
8.0 NOTES......................................................................................................... 41

MPCIB 396 P6 mect s.r.l.
ME3025_13 03/21 5
1.0 OVERVIEW
The MPCIB396 P6 model is an instrument which counts, places or measures by a bi-
directional encoder.
Main characteristics are:
count memory at the switching off (you can exclude this function from the menu).
six digits for counting sign
NPN or PNP encoder inputs open collector, passive pull-up or push-pull, 3 wire
amplified proximity or 2 wire not amplified (configured by jumpers and menu )
three exchange relay alarms (if requested)
programmable multiplying and dividing factor from 1 to 65535
programmable pre-set (offset)
possibility to read on 1, 2 or 4 edges of frequency input
serial outputs (if requested)
analogue outputs (if requested)
one count input and one Up/Down control input
two indipented count inputs A and B with A+B or A-B function
possibility to able the marker pulse by “hold” terminal
1.1 TECHNICAL FEATURES
Table 1
Inputs
Bi-directional npn/pnp encoder
3 wire npn/pnp amplified proximity
2 wire not amplified proximity
Transducer
Supply
14 Vdc / 100 mA not reg.
5Vdc / 50 mA (on request)
Max input frequency
40 KHz
Divider
1 to 65535
Multiplier
1 to 65535
Alarm output
exchange relay 250 Vac / 5A
Supply
90 260 Vac / Vdc; 5W
20 30 Vac / Vdc; 5W
Dimensions
48 x 96 x 75 mm
Piercing template
44.5 mm (height) x 92.5 mm (width)

MPCIB 396 P6 mect s.r.l.
ME3025_13 03/21 6
1.2 DISPLAY MESSAGES
Table 2
r.01.00
software version
ErP 4
item IS = FS
ErP 6
item dEnon = 0
ErP 7
If windows alarm SP2 < SP1
ErP 8
If windows alarm HY > (SP1-SP2)
ErP 9
item dEnon = 0
1.3 WIRING DIAGRAMS
Al1
Al2
In
: it visualises alarm set point (it can be disabled in the menu)
: Clears count (can be disabled in the menu) / fast exit in menu
: it sets up decimal point (it can be disabled in the menu). Used for set up.
: readout print. Used for set up.
: Total counting function (it can be disabled in the menu).
: access at the programming functions and confirm of the selected function
KEYBOARD DESCRIPTION
Led AL1: alarm 1 status indication
Led AL2: alarm 2 status indication
Led Sign: minus sign for negative numbers
Led In: total count on display when on

MPCIB 396 P6 mect s.r.l.
ME3025_13 03/21 7
BASIC TERMINAL BOARD DESCRIPTION
Terminals 1-2-3 - exchange relay output (AL3: 1 = Com, 2 = NC, 3 = NO)
Terminals 4-5-6 - exchange relay output (AL2: 4 = Com, 5 = NC, 6 = NO)
Terminals 7-8-9 - exchange relay output (AL1: 7 = Com, 8 = NC, 9 = NO)
Terminals 13 and 15 - possible power supplies: 24 (20-30Vac/Vdc –no polarity),
220 (90-260Vac). Check the label of the instrument to find
out the power supply voltage to be supplied.
Terminal 16 - encoder ground
Terminal 17 - encoder power supply
Terminal 18 - stop counting / marker pulse abilitation / print (if serial
output requested) / reset total counting
Terminal 19 - reset counting / print (if serial output requested) / reset
total counting
Terminal 20 - encoder marker pulse
Terminal 21 - encoder input 2 (direction input counting if
monodirectional pulse counter)
Terminal 23 - encoder input 1 (input counting if monodirectional input
counting)
Terminal 24 - npn/pnp encoder configuration resistor
Terminal 25, 26, 27 - serial outputs
1.4 WIRING SCHEMATICS
NPN encoder connection
PNP encoder connection
dgnd
reset
input 2
hold
tacca zero
rs
Val
input 1
+
2
1
-
dgnd
reset
input 2
hold
tacca zero
rs
Val
input 1
+
2
1
-

MPCIB 396 P6 mect s.r.l.
ME3025_13 03/21 8
NPN connection PNP connection
dgnd
reset
input 2
hold
tacca zero
rs
Val
input 1
+
-
+
-
dgnd
reset
input 2
hold
tacca zero
rs
Val
input 1
+
-
+
-
1.5 NPN or PNP INPUTS CONFIGURATION
The “hold” and “reset” inputs can be used with “npn” or “pnp” polarity.
“npn” input: short-circuit JP7 and program the menu item “nInP”=nPn
“pnp” input: short-circuit JP14 and program the menu item “nInP”=PnP
The instruments are delivered with NPN inputs.

MPCIB 396 P6 mect s.r.l.
ME3025_13 03/21 9
1.6 PROGRAMMING TIPS
Press key to get into the programming menu.
Press key to search the item to program and the as indicated in
diagram menu
If the set up needs a number to write, use the key to increase the digit
which blinks and key to move the blinking digit and confirm with
key
If the set up needs the selection of an item, use key and confirm with
key
Press key to go to the upper level.
To exit the menu, press : the modified parameters will be stored.

MPCIB 396 P6 mect s.r.l.
ME3025_13 03/21 10
1.7 BASE INSTRUMENT MENU DIAGRAM
Notes:
The symbol means: