Contents
1 Introduction .................................................................................... 1
2 Specifications ................................................................................. 3
3 Outline Construction and Installation .............................................. 4
4 Electric Connection ........................................................................ 8
5 Unpacking、Components and Storage ......................................... 14
6 Operation、Maintenance 、Responsibility& Troublesome ............ 15
7 Responsibility ............................................................................... 17
Our company reserves the modification right for this operation manual
due to renovation of production technology and craftwork. If some
information is changed, no more notice will be edited.
Please pay attention to the latest version.
Our company also reserves the right of final explanation for this manual.
Version: V1.0

1
Thank you very much for selecting Micro Sensor’s product, please take
some time to read this operation manual very carefully before using the
product.
1 Introduction
MPM480 piezo-resistive pressure transmitter is designed by our
company, it adopts the advanced pressure transmitter technology, and
combine with our years of experiences on developing pressure
transmitters. Zero and Span output of MPM480 transmitter can be
precisely calibrated, it has compact size with good accuracy and
stability, and easy adjusting.
As for users’ various requirements, MPM480 pressure transmitter is
available with general version, Explosion-proof version and Ship-use
version.
In which, General version of MPM480 transmitter includes the types for
general use, Flush-diaphragm, Sanitary and Anti-corrosive
applications.
General version of MPM480 pressure transmitter has M20×1.5 or G1/2
male pressure port , it is widely applied for various pressure
measurements and process controls in the fields of petroleum,
chemi-industrial, metallurgy, electric power, light-industry, textile mill,
architecture, hydrography etc.
Flush-diaphragm of MPM480 pressure transmitter has M20×1.5 or “G
1/2” male pressure port , it is suitable for measuring the pressure in

2
food and medical applications, and possible attaching by the media.
Sanitary MPM480 pressure transmitter has a clamp flange connection
(DN25), it is suitable for pressure measurements in food, beverage,
medicine applications.
Anti-corrosive model MPM480 is made of anti-corrosive materials with
Tantalum isolated diaphragm, Hastelloy C housing and pressure
connection, viton O-ring sealing, thus it has good anticorrosion.
Electrical connection of the transmitters is Plug or Cable connection.
Two-wire MPM480 transmitter with plug connection can have a local
LCD or LED indicator to display current value or pressure value on site.
Explosion-proof version of MPM480 includes Intrinsically safe version
ExiaIICT6 and Flameproof version ExdIICT6, in accordance with
national standard GB3836.1-2010 <<Electrical Apparatus for explosive
gas atmospheres- Part 1:General requirements. >>
Flameproof model in accordance with GB3836.2-2010 <<Electrical
Apparatus for explosive gas atmospheres- Part 2: Flameproof
enclosure “d” >>Regulations, Explosion-proof marked with Exd II
CT6Gb.
Intrinsically safe version in accordance with GB3836.4-2010
<<Electrical apparatus for explosive gas atmospheres -Part 4: Intrinsic
safety “i” >>Regulations, Explosionproof marked with ExiaIICT6Ga.
Ship-use version of MPM480 pressure transmitter in accordance with
the related regulations of CHINA CLASSIFICATION SOCIETY (CCS),

3
and certified by CCS Tianjin branch, and achieve a Ship-Use
Certificate.
The product is manufactured in accordance with CMC, permits by
manufacture measurement tools or products in P. R. of China,
2 Specifications
Pressure Range: -1bar…0 ~ 100mbar…1000bar
Overpressure:≤ 2 times FS or 1100bar (minimum value is valid)
Pressure Type: Gauge, Absolute or Sealed
Accuracy: ≤±0.25%FS ≤±0.5%FS ≤±1%FS
Note: The precision of products is related to the range of measurement,
and the precision of products in different range is different.
Long-term Stability: ≤±0.2%FS/year
Zero Temperature Drift: ±0.03%FS/℃ (≤100kPa)
±0.02%FS/℃(>100kPa)
FS Temperature Drift: ±0.03%FS/℃ (≤100kPa)
±0.02%FS/℃ (>100kPa)
Power Supply:15V~28VDC (intrinsic safe version supplied through
safe barrier)
Signal Output: 0/1V~5VDC (3-wire) 4mA~20mADC(2-wire)
0mA~10/20mADC (3-wire);
Operation Temperature:-30℃~80℃(4-pin Plug、7-pin Plug)
-20℃~70℃(cable material: PE, PVC)
-20℃~80℃ (cable material: PUR)

4
-10℃~60℃(Intrinsic safety)
-20℃~60℃(Exd)
Storage Temperature:-40℃~120℃,-20℃~85℃(cable type)
Resistance:≤(U-15)/0.02Ω(Current output);
≥10kΩ(Voltage output)
Pressure Port:M20×1.5 Male
or G 1/2” male
or Clamp (DN25) connection
Housing Protection: IP65
Electrical Connection: Special Plug or Cable 1.5m
Other related device: Intrinsically safe version shall be power supply
via a safe barrier.
Note: Please pay attention for transmitter with LCD or LED, power
supply is 20~28VDC.
3 Outline Construction and Installation
3.1 Construction and Mounting Dimension
Unit:mm
3.1.1 Non flame-proof model (Fig.1):

5
27
SW27
50
22
(112)
12
M20×1.5
26.7
M20×1.5
12
SW27
(113)
27
SW27
M20×1.5
12
(109)
26.7
27
Fig. 1
3.1.2 Flameproof Version (Fig.2):

6
Fig.2
3.2 Installation
3.2.1 Check before Installation
a) The measuring pressure is in the measurement range;
b) The measuring medium is compatible with construction;
c) The measuring medium would not jam the pressure-leading hole.
d) Explosion-proof transmitter must accord with the related regulation
in Part 15 of GB3836.15-2000 Electrical apparatus for explosive
gas atmospheres-Part 15: Electrical installations in hazardous
areas (other than mines).
3.2.2 Installation Method
Generally, the transmitter shall be installed vertically upwards.
Use MPM480 pressure transmitter with flush diaphragm, the effective
depth of the internal thread should not be less than 15mm. Sanitary
MPM480 pressure transmitter using clamp installation.
Sanitary MPM480 pressure transmitter has a clamp connection.
The transmitter can be directly installed on a flange of the measuring
pipe, in order for easy installation or maintenance, it is recommended
S W 3 0
Φ3 0
M 2 0 X 1 . 5
1 2
111
~

7
to install a valve between the flange and the pipe.(see Figure 3).
Pressure Transmitter
Valve
Pipe
Fig. 3
3.3 Attenation
a) Don’t stab the pressure leading hole of the pressure port by any
sharp things, and do not touch the diaphragm by your fingers, it
may damage the sensor.
b) Flush-diaphragm transmitter and Sanitary transmitter always has a
plastic protection cover on the pressure port for avoiding any
possible damage on the diaphragm, please do not take it off until
installing the transmitter.
c) For flush-diaphragm version, do not try to use the sealing way of
twisting any sealing tape around the pressure port male of flush
diaphragm transmitter, it may affect the measuring stability or
damage the transmitter.
d) In case the transmitter is operating under thunder or lightning area,
please install an anti-thunder device in the circuits.

8
4 Electric Connection
4.1 The transmitter is connected with the outside circuit
through plug or special cable.
The pin arrangements of socket are to see Fig. 4, and pin definitions
are as follows:
≈
30
1
S
+
3
2
10A
250V
GDM
VDE
lift
27.5 18
18
36
2
30
GSP-U
+
S
16
400
2
3
1
33.5
(50)
19
SW17
Fig. 4
Table 1
Pin
2-wire 3-wire
1 +V +V
2 OV/+OUT GND
3 Null +OUT
The electric definitions of cable are as follow:
Altri manuali per MPM480
1
Indice
Altri manuali Microsensor Strumento di misura

Microsensor
Microsensor MDM7000 Manuale utente

Microsensor
Microsensor MPM486 Manuale utente

Microsensor
Microsensor MPM380 Manuale utente

Microsensor
Microsensor MPM426WS Manuale utente

Microsensor
Microsensor MFE600C Manuale utente

Microsensor
Microsensor MFE600H Series Manuale utente

Microsensor
Microsensor MPM430 Manuale utente

Microsensor
Microsensor MPM Manuale utente