NCR WorldMark 4380 Manuale utente

B003-0181-A000
11/97
WorldMark4380
Deskside Hardware Installation Guide

The product described in this book is a licensed product of NCR Corporation.
Adaptec, the Adaptec logo, AHA, Altra, AVA, EZ-SCSISelect, and SlimSCSI are trademarks of Adaptec, Inc. which
may be registered in some jurisdictions. IBM, AT, OS/2, and Micro Channel are registered trademarks of
International Business Machines Corporation. Novell and NetWare are registered trademarks of Novell, Inc.
PhoenixBIOS is a trademark of Phoenix Technologies Ltd. Windows, Windows NT, MS-DOS, MS, and Microsoft
are registered trademarks of Microsoft Corporation. UNIX is a registered trademark of UNIX Systems Laboratories
in the United States and other countries. PROCOMM PLUS is a registered trademark of Datastorm Technologies,
Inc. All other trademarks are owned by their respective owners. Microsoft Corporation’s license agreement
precludes copying, disassembling, or reverse compiling software programs, or making any backup copies of the
software programs. You are not authorized to copy program files, or use any backup diskette (made for the
purpose of data backup and recovery from serious Flash failures) on any other system.
It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and
firmware become available. NCR, therefore, reserves the right to change specifications without prior notice.
All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In
some instances, photographs are of equipment prototypes. Therefore, before using this document, consult with
your NCR representative or NCR office for information that is applicable and current.
To maintain the quality of our publications, we need your comments on the accuracy, clarity, organization, and
value of this book.
Address correspondence to:
Systems Information
NCR Corporation
3325 Platt Springs Road
West Columbia, SC 29170
Copyright © 1997
By NCR Corporation
Dayton, Ohio U.S.A.
All Rights Reserved

WorldMark 4380 Deskside Hardware Installation Guide 1
Congratulations!
And thank you for purchasing the NCR WorldMark 4380 Server. This document will guide you
through the steps needed to set up your server for the first time.
Note: No boards should be removed from or added to the server until after operating system
installation is complete.
Refer to the Important Support Information section at the end of this document for information
about:
• Installation help.
• Verifying remote support functionality.
• Sources for updated software, diagnostics, and server information.
Other Information Sources
The NCR Info Line Faxback Services at (803) 939-2082 may have updated software installation
information. Refer to the WorldMark 4380 Deskside Product Guide for additional information
about troubleshooting, error and beep codes, and remote support. Refer to the Server Software
Guide (OctaSCALE) for information about configuring your server.
Warranty information for the WorldMark 4380 server is available from your local sales
organization.
Additional Documentation
Additional documentation is available for your WorldMark 4380 server and can be ordered
through your NCR representative:
Documentation Order Number
WorldMark 4300 Deskside Service Guide
BST0-2139-5500
NCR Remote Services User Guide
BD20-1401-B000
WorldMark 4300 Server Management Product Guide
BD20-1398-B000
AMIDiag User’s Guide
BST0-2141-1300
AMIDiag Supplement (OctaSCALE)
BST0-2139-5700

1. Unbox and Check Your Shipment
2
1. Unbox and Check Your Shipment
To unpack the system:
1. Remove the foam “packing ring” from around the server.
2. Remove the protective plastic from around the server.
3. Remove the shipping insert in the tape drive.
Make sure you have everything to complete the hardware installation:
• Either an external modem with AC power cable, serial port cable, and phone cable or a Server
Management Board with internal modem, serial port cable, and phone cable
• Monitor (customer provided), keyboard, mouse, and associated cables
• Antistatic wrist strap
• Documentation:
– WorldMark 4300 Installing Windows NT Server
– WorldMark 4300 Installing MP-RAS
– WorldMark 4380 Deskside Product Guide
– Server Software Guide (OctaSCALE)
– System Site Log
Remove the server off the pallet by the best means available (hoist or by hand). Place server in a
location that is in accordance with the specifications in the Site Preparation Guide.

2. Check the Power Cord and Plug It Into the Server
WorldMark 4380 Deskside Hardware Installation Guide 3
2. Check the Power Cord and Plug It Into the Server
IMPORTANT: Do not modify or use the supplied AC power cord if it is not the exact type
required. Replace it, if necessary. Make sure the supplied power cord is compatible with the AC
wall outlet type in the area where the server is to be installed.
The wall receptacle must be terminated in grounding-type male plug designed for use in the region,
and be labeled as certified by an agency acceptable in the region.
When you are sure that you have the correct power cord, plug it into the server AC power
connector.
Do not plug the power cord into the wall outlet yet.

3. Connect Peripherals
4
3. Connect Peripherals
IMPORTANT: Do not plug in the server before connecting peripherals.
You need to install:
• Keyboard
• Video monitor
• Mouse
You must install a monitor and keyboard to configure the system. You may remove the monitor
and keyboard after running the System Configuration Utility (SCU).
Connect external peripheral devices such as a printer by following instructions included with the
device.
Connect a parallel printer to parallel port LPT1. Connect a serial printer to serial port COM2.
The following figure shows the location of external connector for peripheral devices.
6
7
8
9
2
1
3
4
5
NUMBER CONNECTOR
1 A/C power
2 Keyboard
3 COM2 serial port
4 Video monitor
5 Parallel port LPT1
6 Server Management Board external connectors
7 Mouse
8 COM1 serial port
9 Future expansion port (marked “LPT1”)

4. Connect the Remote Support Modem
WorldMark 4380 Deskside Hardware Installation Guide 5
4. Connect the Remote Support Modem
IMPORTANT: Do not plug in the server before connecting peripherals.
For the server containing a Server Management Board with an internal modem, follow the
procedures below to allow remote support functionality.
For the server containing an SMB with an internal modem:
• Run the external cable from “Comm In” to COM1 on the back of the chassis.
• Connect your telephone line into the “Line” connector on the SMB.

4. Connect the Remote Support Modem
6
For the server with an external modem, follow the procedures below.
RJ11 connector
to modem
Connect to
analo
g
modem
connection
Connect to
COM1 port
on server
Connect
to AC
power outlet
25-pin connector
to modem Power suppl
y
connector
to modem
3
2
1
To install the modem:
1. Connect the enclosed computer interface cable from the 9-pin COM1 port on the server to the
25-pin connector on the modem.
2. Connect the modem power supply cable to the power supply connector.
3. Connect the telephone line cable from the analog modem connection in your facility to the
RJ11 connector on the modem.
4. Plug the modem power supply into the AC power outlet.
5. Place modem on top of the server. The power LED should be illuminated.

5. Connect the Network Cable
WorldMark 4380 Deskside Hardware Installation Guide 7
5. Connect the Network Cable
If a network adapter is installed, you need to plug your network cable into the appropriate network
connector.
The network connector is located in one of the 15 PCI or 4 EISA add-in board slots. The exact
location of the network connector depends upon the type of network card you order.
4
3
2
1
NUMBER SLOTS
1 PCI slots on secondary system board
2 PCI slots on primary system board
3 Shared PCI/EISA slot on primary system board
4 EISA slots on primary system board

6. Plug in the Power Cord
8
6. Plug in the Power Cord
The system requires up to three AC power receptacles as follows:
Server 200-240 Vac
Modem Power Supply 110/220 Vac (if applicable)
Monitor 110/200 Vac
Plug the server, modem power supply (as applicable), and monitor power cords into a grounded
AC electrical outlet. It is recommended that you do not use an extension cord.
Indice