Newport Electronics 558B Manuale utente

558B
CURRENT LOOP INDICATOR
Operator’s Manual
http://www.newportUS.com/man als
®
NEWPORT
Electronics, Inc.

Counters
Frequency Meters
PID Controllers
Clock/Timers
Printers
Process Meters
On/Off Controllers
Recorders
Relative umidity
Transmitters
Thermocouples
Thermistors
Wire
Rate Meters
Timers
Totalizers
Strain Gauge Meters
Voltmeters
Multimeters
Soldering Iron Testers
p pens
p Controllers
p Electrodes
RTDs
Thermowells
Flow Sensors
NEWPORT
Electronics, Inc.
®
For Immediate Assistance
In the U.S.A. and Canada: 1-800-NEWPORT
®
In Mexico: (95) 800-NEWPORT
SM
Or call your local NEWPORT Office.
Internet e-mail
Additional products from
NEWPORTnetSM On-Line Service
http://www.newportUS.com
is the policy of NEWPORT to comply with all worldwide safety and EMC/EMI regulations that
EWPORT is constantly pursuing certification of its products to the European New App
irectives. NEWPORT will add the CE mark to every appropriate device upon certification.
he information contained in this document is believed to be correct but NEWPORT Electronic
ccepts no liability for any errors it contains, and reserves the right to alter specifications without
WARNING: These products are not designed for use in, and should not be used for, patient conn
pplications.
This device is marked with the international caution symbol. It is important to read the
Guide before installing or commissioning this device as it contains important information r
to safety and EMC.

TABLE OF CONTENTS
1.0 GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.0 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.1 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Accuracy at 25°C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.3 Analog-To-Digital Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.4 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.5 Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.6 Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.0 MEC ANICAL ASSEMBLY AND INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.1 Safety Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.2 Intrinsic Safety Parameters for FM (Factory Mutual) . . . . . . . . . . . . . . . . . . . . . 4
3.3 Installation/Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4.0 SIGNAL INPUT CONNECTIONS (P3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.0 CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5.1 Standard Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5.2 Field Configuration Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6.0 CUSTOMER CONFIGURATION AND CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . .9
6.1 Formula . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
6.2 Configuration Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.3 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.4 Factory-Setup Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7.0 WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
ILLUSTRATIONS
Figure 3-1 Exploded View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 3-2 DIN Case Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Figure 5-1 Main Board Jumper Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Figure 7-1 Wiring Diagram for 558B Usage for FM (Factory Mutual) . . . . . . . . . . . . 11
i

UNPACKING INSTRUCTIONS
Remove the Packing List and verify that you have received all equipment,
including the following:
QTY DESCRIPTION
1 Current Loop Meter Indicator with all applicable connnectors attached.
1 Owner's Manual
1 Factory Setup Label
If you have any questions about the shipment, use the phone number for the
Customer Service Department nearest you.
When you receive the shipment, inspect the container and equipment for signs of
damage. Note any evidence of rough handling in transit. Immediately report any
damage to the shipping agent.
The carrier will not honor damage claims unless all
shipping material is saved for inspection. After
examining and removing contents, save packing
material and carton in the event reshipment is
necessary.
ii

1
1.0 GENERAL INFORMATION
Model 558B two-wire current-loop indicator accepts 1-5 mA, 4-20 mA, or 10-50 mA
process signals and digitally displays the process variable in percentage or
engineering units of such measurements as pressure, flow, temperature and level.
No separate power supply or power connections are required, since the 558B
obtains operating power directly from the current loop with a voltage drop of less
than 2.5 V. It can tolerate current overdrives up to 200 mA forward and 1000 mA
reverse.
The compact 558B circuit is mounted in a black polycarbonate case with the
standard 1/8 DIN panel-mount bezel and a depth of less than 110 mm (4.33 in).
Five 12.7 mm (0.5 in) high liquid crystal 7-segment digits are used to display
±1999 active counts plus one or two dummy right-hand zeros.
The 558B displays from -1999 to 1999 counts with the option of one or two
dummy right-hand “0” digits. Zero suppression or elevation capability exceeds
full scale. Program jumpers are used to scale the readout for percentage or
engineering-unit display. Both zero and span are fine-tuned with multiturn
potentiometers accessible through the display board, requiring lens removal for
readjustment.
When removed from its case, the 558B can be programmed with gas-tight
jumpers for three input ranges (1-5, 4-20 or 10-50 mA), four coarse zero ranges,
four decimal-point locations and the dummy right-hand zeros. Two additional
jumpers are provided to reverse the span slope so that increasing the input can
cause a reading decrease; thus a 4-20 mA input can be programmed to produce
a 2000 to -18000 reading when one dummy right-hand zero is also used.

2
2.0 SPECIFICATIONS
2.1 INPUT
Current 1-5 mA, 4-20 mA or 10-50 mA
Protection 200 mA max forward and 1000 mA max
reverse
Voltage Drop 2.5 V max forward and 1.2 V max reverse
Span Range 100 to 2000 counts continuous adjustment
with a multiturn potentiometer
Zero Range The multiturn zero potentiometer can displace
the displayed reading by ±500 counts from the
center of each of the four overlapping zero
ranges, provided that the resultant is within the
±1999 count display capability.
Span Slope Positive or Negative
Normal Mode Rejection
at 50/60 z 46 dB minimum
2.2 ACCURACY AT 25°C
Maximum error ±0.1% R ±1 count
Zero tempco ±0.1 ct/K typ, ±0.3 ct/K max
Span tempco ±0.005%S/K typ, ±0.015%S/K max
2.3 CONVERSION
Technique Dual-slope, average value with autozero
correction
Polarity Determined automatically at the end of input
integration period
Input integration period 100 milliseconds (nominal value)
Reading rate 2.5/second

3
2.4 DISPLAY
Type 7-segment LCD
Color Black digits with white background
Symbols -1.8.8.8.0.0, 12.7 mm (0.5 in) height
Polarity Minus sign
Overrange Three least-significant digits blank
Extra digits One or two dummy right-hand zeros,
jumper-selectable
Decimal points Four positions, jumper-selectable
Lifetime (to 2:1 contrast ratio) More than 30,000 hours
Temperature derating 2:1 for each 10°C above 60°C
umidity derating 2:1 for each 10%R above 60%R
2.5 ENVIRONMENT
Standard operating temp 0 to 55°C
Extended operating temp option
(conformally coated) -40 to +85°C
umidity To 95% at 40°C
Bezel cover option Splash-proof
2.6 MEC ANICAL
Weight 170 g (6 oz)
Case material Black polycarbonate, 94V-0 flammability rating
Case size
Bezel ( xWxT) 48 x 96 x 7.67 mm
Depth behind bezel
with mounting hardware Less than 110 mm
Panel cutout ( xW) 45 x 92 mm
Electrical connections 3-terminal screw clamp connector
Wire size 0.13 mm2- 2.5 mm2(AWG 26-14)

4
3.0 MECHANICAL ASSEMBLY AND INSTALLATION
3.1 SAFETY CONSIDERATIONS
To ensure safe operation, follow the guidelines below:
VISUAL INSPECTION: Do not attempt to operate the instrument if damage
is found.
SIGNAL WIRING: Insert the proper plus and minus signal wires into the plug-in
screw-clamp connector terminals marked plus and minus. Ensure that the wires
are securely clamped in the plug-in connector by rotating the screws in the
plug–in connector clockwise but do not exceed a torque of .5 newton-meter
(.37 pound-foot). Then plug the connector firmly into the socket located on the
rear panel of the meter.
RAIN OR MOISTURE: Do not expose the instrument to condensing moisture.
3.2 INTRINSIC SAFETY PARAMETERS FOR FM (FACTORY MUTUAL)
Certificate No. 2Y4A4.AX
V max=12.5 V,
Imax=250 mA
Intrinsically Safe for Class I, II and III, Division 1, Groups, A,B,C,D,E,F and G
hazardous locations.
Ci=8.6 µF
Li=0 m

3.3 INSTALLATION/REMOVAL
The 558B is housed in a 1/8 DIN case. The electronic circuitry can be installed or
removed from the front and is attached to the case with two M4 screws through the
rear panel.
Panel Mounting
1. Remove the two thumbnuts on the rear of the case.
2. Slide the sleeve off the case (see Figure 3-1 Exploded View).
3. Verify the panel cutout dimensions in Figure 3-2 Case Dimensions. Insert the
case in the panel cutout from the front and slide the sleeve on from the rear.
Install the two thumbnuts to secure the sleeve to the case.
Main Board Access:
1. Case must be removed from sleeve.
2. Remove lens from case.
3. Slide main board from front of case.
Fig re 3-1 Exploded View (incl des rear panel)
5
SLEEVE
T UMBNUT
CONFIGURATION LABEL
(BACK SIDE OF DISPLAY BOARD)
T READED STUD
REAR PANEL
MAIN BOARD
DISPLAY
BOARD
FRONT LENS
ELECTROSTATIC RISK
DO NOT RUB OR
CLEAN WIT SOLVENT
J3 B
REAR CONNECTOR (P3)
FOR SIGNAL INPUT
1 2 3
ID. LABEL
CASE
PANEL

6
Fig re 3-2. DIN Case Dimensions
4.0 SIGNAL INPUT CONNECTIONS (P3)
The signal input connections for all meters are made at connector P3 as follows
(see Figure 3-1):
P3 Connection Signal
1 Signal i
2 Signal Lo
3 No Connection
4.15 [105.4] SLEEVE
3.50 [88.9]
1.89 [48.0]
3.78 [96.0] 7.9 [0.31] MAX
CASE
TOP VIEW SIDE VIEW
PANEL CUT-OUT
[45.00 +0.61/-0.00]
R
PANEL T ICKNESS:
1.772 +.024/-.000
3.622 +.032/-.000
[92.00 +0.81/-0.00]
[1.5]
0.06
4 PLCS
0.25 [6.4] MAX
0.03 [0.8] MIN
NOTES: DIMENSIONS ARE IN INC ES [MILLIMETERS].
Indice
Altri manuali Newport Electronics Strumento di misura

Newport Electronics
Newport Electronics wi Series Manuale utente

Newport Electronics
Newport Electronics INFCP-B Series Manuale utente

Newport Electronics
Newport Electronics 215-2 Manuale utente

Newport Electronics
Newport Electronics INFINITY INFCDT Manuale utente

Newport Electronics
Newport Electronics INFINITY Series Manuale utente

Newport Electronics
Newport Electronics IDP INFINITY D Manuale utente

Newport Electronics
Newport Electronics i Series Manuale utente

Newport Electronics
Newport Electronics 204B Manuale utente